MAURY USCG vessel records Sign in
← All vessels

MAPLE PIONEER

MAPLE PIONEER is a 2008 freight ship. The Coast Guard has recorded 14 inspections since 2008, most recently in May 2020, along with 19 deficiencies and 8 operational controls.

Records from 2008 to 2020. Most recent: inspection, 12 May 2020.

Built
2008
Last inspected
12 May 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9493494 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
990614
Flag
HONG KONG
—
Maury page id
psix-990614

Inspections, by type

…with no type recorded6
Years with a record 5 calendar years (2008–2020)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it20763 - Convention (Subpart B), Gross Ton
41799 - Displacement, Metric Ton
32500 - Dead Weight, Metric Ton
11627 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

12 May 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7085224
30 March 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6933188
8 November 2019 Ballast Water Examination · Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6851960
7 November 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6850430
15 April 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6662808
7 June 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6428807
3 June 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6432906
27 October 2010 ISPS III Exam · PI Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3878428
26 October 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3878415
12 October 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3868764
12 October 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3872563
22 September 2010 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3855150
24 November 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3368355
18 November 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3365745

Deficiency record · 19

14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 9 November 2019 Resolved
14105 - The arrangement on board ship for the extraction of samples from the 15ppm bilge separator discharge line to the 15ppm bilge alarm should give a truly representative sample of the effluent with an adequate pressure and flow. PSCO conducted test of oil content meter while the oily water separator was operating in recirculation mode and discovered that the system would still simulate an overboard discharge when oil content meter was presented with a fresh water sample. Additionally, the oil content meter’s sample valve was labeled incorrectly, and crew has been operating system in fresh water sample mode when thought to be in bilge water or discharge sample mode. - MARPOL 73/78 Annex I/14.7/MEPC.107(49)6.2.2 - 30abc
Action required: 30 - Ship detained
Due 9 November 2019
Resolved 17 November 2019
Resolution: Vsl replaced overboard solenoid valve and switch at OCM. PSCO tested OWS and OCM alarms. All sat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 9 November 2019 Resolved
15106 - The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. (1) 34 immersion suits found in unsatisfactory condition. Vessel's SMS (Doc#SMO-412, 6.8.4) requires monthly checks and once in three months donning of suit. Three months (August, September, October 2019) of monthly maintenance and inspection checklists (form 07) signed by 3/O and Master indicate satisfactory condition of immersion suits. (2) Fuel oil purifying unit local water fire-extinguishing system nozzle discharge unsatisfactory. Generator #1 local water fire-extinguishing system smoke alarm inoperable. Vessel conducts monthly and annual checks of water mist system per Monthly Maintenance and Inspection checklist - FFA form 08 and form 12 (Annual). Three months (August, September and October) and 2018 checklists records indicate satisfactory condition of all equipment. During test of smoke detector, crew attempted to use a heat gun to test. Crew was unable to reset watermist system for 30+ minutes following activation, incorrectly believing that the bridge panel must reset the system. (3) Improper operation of OWS permits oily waste to be discharged overboard. Crew is unfamiliar with operation of OWS and OCM. No procedures available for testing of OCM alarms. Improper labeling of valve. Due to objective evidence in the above deficiencies that the vessel is not in substantial compliance with relevant conventions, the Captain of the Port questions the adequacy and/or implementation of the vessel's SMS under the ISM code. An audit is recommended to be conducted within 30 days by the flag state or RO to determine whether the ship is operating in accordance with the ISM code. Provide decision to the U.S. Coast Guard.
Action required: 30 - Ship detained
Due 9 November 2019
Resolved 17 November 2019
Resolution: Vessel conducted internal and external audits. CCS auditor found 5 major non-conformities and 3 non-conformities.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 November 2019 Resolved
07106 - A fixed fire detection and fire alarm system shall be installed in machinery spaces where the main propulsion and associated machinery... are provided. One smoke detector in engine room was held in place with a zip tie and another one held in place with tape. - 74SOLAS(14 cons.) II-2/7.4.1.2.2.2 - 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2019
Resolved 17 November 2019
Resolution: Detectors properly mounted. PSCO verified, all sat.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 9 November 2019 Resolved
99102 - Maintenance, testing and inspections shall be carried out based on the guidelines developed by the organization. In addition to the onboard maintenance and inspections stated in these guidelines, manufacturer’s maintenance and inspection guidelines should be followed. Vessel’s crew was unable to provide manufacturer’s instructions for the water mist system smoke and heat detectors. - 74SOLAS (14 cons.) II-2/14.2.2.1/MSC.1/Circ.1432 - 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2019
Resolved 17 November 2019
Resolution: Instruction manuals procured from manufacturer. PSCOs verified manuals onboard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 November 2019 Resolved
07120 - The purpose of this regulation is to provide means of escape so that persons on board can safety and swiftly escape. PSCO observed padlock on primary escape from engine room as per Fire Control Plan. Door had no means to release lock in emergency. - 74SOLAS(14)II-2/13.1 - 10c
Action required: 10 - Deficiency Rectified
Due 9 November 2019
Resolved 9 November 2019
Resolution: Crew removed padlock from the engine room escape door.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2019 Resolved
13199 - Hydraulic power operated steering gear shall be provided with a fixed storage tank having sufficient capacity to recharge at least one power activating system. PSCO observed tank level to be below minimum level indicated. -74SOLAS(04)II-I/29.12.3 -10c
Action required: 10 - Deficiency Rectified
Due 9 November 2019
Resolved 9 November 2019
Resolution: Crew was able to add hydraulic oil to fixed storage tank to have adequate capacity to recharge one power activating system.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 8 November 2019 Resolved
11119- Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. 34 immersion suits zippers are not in working order or the seams are severely deteriorated rendering them inoperable. -74SOLAS (14cons.) III/20.2. -30abc
Action required: 30 - Ship detained
Due 8 November 2019
Resolved 17 November 2019
Resolution: Vessel procured and replaced 34 immersion suits onboard. PSCO verified new immersion suits placed on station.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 November 2019 Resolved
07109 - Machinery spaces of category A above 500 m/3 in volume shall... be provided by an approved type of fixed water based or equivalent local application fire-extinguishing system... The system should be available for immediate use and capable of continuously supplying water based medium for at least 20 min... During test of fuel oil purifier local water fire-extinguishing system (hypermist), nozzle discharge pressure and volume inadequate to extinguish fire. During test of generator #1 local water fire-extinguishing system, smoke detector did not activate, preventing the system from automatically operating to extinguish a fire. - 74SOLAS II-2/10.5.6; MSC.1/circ.1387. -30abc
Action required: 30 - Ship detained
Due 8 November 2019
Resolved 17 November 2019
Resolution: Clogged pipe to F/O purifying hypermist unit cleared. #1 Generator smoke detector replaced. PSCOs op tested hypermist system, all sat.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 7 June 2018 Resolved
0611 - Life Saving Appliances - Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. The normal equipment of every lifeboat shall consist of: watertight receptacles containing a total of 3 liters of fresh water for each person the lifeboat is permitted to accommodate; and a food ration totaling not less than 10,000KJ for each person the lifeboat is permitted to accomodate, these rations shall be kept in an airtight packaging and stowed in a watertight container. Free-fall lifeboat holds a complement of 25 passengers, requiring 25 10,000KJ food rations and 75 liters of water. PSCO observed free-fall lifeboat to have 11 10,000KJ food rations and 69 liters of water on-board. Replace food and water rations as per LSA requirement prior to departure from port. SOLAS 74 (14) Cons. III/20.2; LSA 4.4.8 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2018
Resolution: Received, reviewed and accepted proper documentation from [name withheld] stating the deficiency was rectified. The vessel's Master provided a photo and reciept showing the purchase of 7.5L emergency drinking water rations and 16 emergency food rations.
Engineering › Freshwater System (jacketwater cooling) › Level Control
Issued 27 October 2010 Resolved
1410- Propulsion main engine- Vessel experienced a power irregularity at MM135. PSCO conducted examination of throttle movement, logs and engine room alarm history. Vessel had 5 alarms on the main engine, Two J/W high temp, one J/W low pressure, and two high exhaust temps. SOLAS 74a, 2004 cons, II-1/26
Action required: 705 - Other - as specified
Resolved 28 October 2010
Resolution: Received, reviewed and accepted class report from Lloyd''s Register of Shipping, stating the deficiency was rectified. All associated J/W temperature and pressure devices were open and inspected and found satisfactory.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 12 October 2010 Resolved
The vessel experienced a Propulsion Loss while in the Mississippi River due to the cylinder oil tank remote shutdown valve not being reset after testing..
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2010
Resolved 13 October 2010
Resolution: Received, reviewed, and accepted class report from [name withheld] stating the cylinder oil tank remote shutdown valve was reset, tested and found satisfactory.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 24 November 2008 Resolved
0715-The ships fire detection system appears to not operate according to design. The crew does not have the appropriate equipment to test ships fire detection system. Licensed engineers’ used cigarettes to test smoke detection system . Address the operation of the entire fire detection system . Make sure appropriate testing gear is on board prior to departure from Stockton
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2008
Resolved 4 December 2008
Resolution: Received class report #LAN0820266 Stating that a condition of class has been issued for the detectors and that the fire detection system is to be kept under observation and the engine room is to be manned
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 November 2008 Resolved
1740 - The oil content meter display is inoperative. the display fails to indicate when the oil content exceeds 15 PPM. Address the repair calibration and testing to the satisfaction of class prior to departure from port of San Francisco
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2008
Resolved 4 December 2008
Resolution: Received class report#LAN0820266 Stating That the defective oil content meter was replace with a spare which was supplied by the manufacture with the type approval letter and letter of calibration. After replacement meter was tested and found satisfactor
Lifesaving › Inflatable Liferafts › Container Construction
Issued 24 November 2008 Resolved
0628 - Life rafts port /Stbd sides of the house appear to be damaged by cradles. the life rafts casing is being dented underneath. The straps are also loose allowing the life raft to slide back and forth during heavy weather. The painter is also not secured correctly. All three life rafts address to the satisfaction of class.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 November 2008
Resolved 4 December 2008
Resolution: Received class report #LAN0820266 Stating that the installation of the weak link/ painter was secured to the hydraulic release on all life rafts in accordance with the manufactures instructions
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 24 November 2008 Resolved
2535 - Ships ballast water management has two plans. One is approved by class and created during construction . The other was written by the operating company. both plans have missing and contradicting information such as ballast capacities and sampling diagrams. Address to flag /class. 33 CFR 151.2035(a)(7)
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 November 2008
Resolved 9 November 2009
Resolution: Ships ballast water management now verified and placed on board approved by class dated 10SEP09 now used by vessel M/V Maple Pionner
Fire Fighting › Structural - B Class Divisions › Doors
Issued 24 November 2008 Resolved
0750 - B-class door into officers laundry is missing vent/kick out panel replace or fix to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2008
Resolved 4 December 2008
Resolution: Received class report #LAN0820266 Stating that the kick out panel/vent was installed and found satisfactory
Operations/Management › Ballast Water Managment › Submission of Report
Issued 24 November 2008 Resolved
Several errors were found on the ballast reporting form submitted to the NBIC. errors were discussed with the chief mate/ captain . chief will submit a amended form. Corrected on the spot.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 November 2008
Resolved 24 November 2008
Resolution: amended form
Construction/Loadline › Structures › Door
Issued 24 November 2008 Resolved
1270 - Water tight door from crews mess to weather deck is missing a dog. Repair to satisfaction of class. Other door from passage way by crews mess will not close all the way. Class should inspect all water tight doors. ICLL 88 REG 12
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2008
Resolved 4 December 2008
Resolution: Received class report #LAN0820266 Stating a condition of class has been issued for weather tight doors of port/stbd acomidation spaces temporary means of sealing will be used for passage from USA to next port.The missing dog on crews mess was replaced
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 November 2008 Resolved
1530 - Radar - Xband radar operating improperly. Reports were made to the trigger video, azimuth, and headline missing alarms. radar must be repair to normal operating specifications by certified tech.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2008
Resolved 18 November 2008
Resolution: Tech report received. LOD rescinded.