MAPLE PIONEER is a 2008 freight ship. The Coast Guard has recorded 7 inspections since 2018, most recently in May 2020, along with 9 deficiencies and 5 operational controls.
Records from 2018 to 2020. Most recent: inspection, 12 May 2020.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it20763 - Convention (Subpart B), Gross Ton 41799 - Displacement, Metric Ton 32500 - Dead Weight, Metric Ton 11627 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
7 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; 5 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 7
12 May 2020Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7085224
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 9 November 2019Resolved
14105 - The arrangement on board ship for the extraction of samples from the 15ppm bilge separator discharge line to the 15ppm bilge alarm should give a truly representative sample of the effluent with an adequate pressure and flow. PSCO conducted test of oil content meter while the oily water separator was operating in recirculation mode and discovered that the system would still simulate an overboard discharge when oil content meter was presented with a fresh water sample. Additionally, the oil content meter’s sample valve was labeled incorrectly, and crew has been operating system in fresh water sample mode when thought to be in bilge water or discharge sample mode. - MARPOL 73/78 Annex I/14.7/MEPC.107(49)6.2.2 - 30abc
Action required: 30 - Ship detained
Due 9 November 2019
Resolved 17 November 2019
Resolution: Vsl replaced overboard solenoid valve and switch at OCM. PSCO tested OWS and OCM alarms. All sat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 9 November 2019Resolved
15106 - The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. (1) 34 immersion suits found in unsatisfactory condition. Vessel's SMS (Doc#SMO-412, 6.8.4) requires monthly checks and once in three months donning of suit. Three months (August, September, October 2019) of monthly maintenance and inspection checklists (form 07) signed by 3/O and Master indicate satisfactory condition of immersion suits.
(2) Fuel oil purifying unit local water fire-extinguishing system nozzle discharge unsatisfactory. Generator #1 local water fire-extinguishing system smoke alarm inoperable. Vessel conducts monthly and annual checks of water mist system per Monthly Maintenance and Inspection checklist - FFA form 08 and form 12 (Annual). Three months (August, September and October) and 2018 checklists records indicate satisfactory condition of all equipment. During test of smoke detector, crew attempted to use a heat gun to test. Crew was unable to reset watermist system for 30+ minutes following activation, incorrectly believing that the bridge panel must reset the system.
(3) Improper operation of OWS permits oily waste to be discharged overboard. Crew is unfamiliar with operation of OWS and OCM. No procedures available for testing of OCM alarms. Improper labeling of valve.
Due to objective evidence in the above deficiencies that the vessel is not in substantial compliance with relevant conventions, the Captain of the Port questions the adequacy and/or implementation of the vessel's SMS under the ISM code. An audit is recommended to be conducted within 30 days by the flag state or RO to determine whether the ship is operating in accordance with the ISM code. Provide decision to the U.S. Coast Guard.
Action required: 30 - Ship detained
Due 9 November 2019
Resolved 17 November 2019
Resolution: Vessel conducted internal and external audits. CCS auditor found 5 major non-conformities and 3 non-conformities.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 November 2019Resolved
07106 - A fixed fire detection and fire alarm system shall be installed in machinery spaces where the main propulsion and associated machinery... are provided. One smoke detector in engine room was held in place with a zip tie and another one held in place with tape. - 74SOLAS(14 cons.) II-2/7.4.1.2.2.2 - 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2019
Resolved 17 November 2019
Resolution: Detectors properly mounted. PSCO verified, all sat.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 9 November 2019Resolved
99102 - Maintenance, testing and inspections shall be carried out based on the guidelines developed by the organization. In addition to the onboard maintenance and inspections stated in these guidelines, manufacturer’s maintenance and inspection guidelines should be followed. Vessel’s crew was unable to provide manufacturer’s instructions for the water mist system smoke and heat detectors. - 74SOLAS (14 cons.) II-2/14.2.2.1/MSC.1/Circ.1432 - 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2019
Resolved 17 November 2019
Resolution: Instruction manuals procured from manufacturer. PSCOs verified manuals onboard.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 November 2019Resolved
07120 - The purpose of this regulation is to provide means of escape so that persons on board can safety and swiftly escape. PSCO observed padlock on primary escape from engine room as per Fire Control Plan. Door had no means to release lock in emergency. - 74SOLAS(14)II-2/13.1 - 10c
Action required: 10 - Deficiency Rectified
Due 9 November 2019
Resolved 9 November 2019
Resolution: Crew removed padlock from the engine room escape door.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2019Resolved
13199 - Hydraulic power operated steering gear shall be provided with a fixed storage tank having sufficient capacity to recharge at least one power activating system. PSCO observed tank level to be below minimum level indicated. -74SOLAS(04)II-I/29.12.3 -10c
Action required: 10 - Deficiency Rectified
Due 9 November 2019
Resolved 9 November 2019
Resolution: Crew was able to add hydraulic oil to fixed storage tank to have adequate capacity to recharge one power activating system.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 8 November 2019Resolved
11119- Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. 34 immersion suits zippers are not in working order or the seams are severely deteriorated rendering them inoperable. -74SOLAS (14cons.) III/20.2. -30abc
Action required: 30 - Ship detained
Due 8 November 2019
Resolved 17 November 2019
Resolution: Vessel procured and replaced 34 immersion suits onboard. PSCO verified new immersion suits placed on station.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 November 2019Resolved
07109 - Machinery spaces of category A above 500 m/3 in volume shall... be provided by an approved type of fixed water based or equivalent local application fire-extinguishing system... The system should be available for immediate use and capable of continuously supplying water based medium for at least 20 min... During test of fuel oil purifier local water fire-extinguishing system (hypermist), nozzle discharge pressure and volume inadequate to extinguish fire. During test of generator #1 local water fire-extinguishing system, smoke detector did not activate, preventing the system from automatically operating to extinguish a fire. - 74SOLAS II-2/10.5.6; MSC.1/circ.1387. -30abc
Action required: 30 - Ship detained
Due 8 November 2019
Resolved 17 November 2019
Resolution: Clogged pipe to F/O purifying hypermist unit cleared. #1 Generator smoke detector replaced. PSCOs op tested hypermist system, all sat.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 7 June 2018Resolved
0611 - Life Saving Appliances - Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. The normal equipment of every lifeboat shall consist of: watertight receptacles containing a total of 3 liters of fresh water for each person the lifeboat is permitted to accommodate; and a food ration totaling not less than 10,000KJ for each person the lifeboat is permitted to accomodate, these rations shall be kept in an airtight packaging and stowed in a watertight container. Free-fall lifeboat holds a complement of 25 passengers, requiring 25 10,000KJ food rations and 75 liters of water. PSCO observed free-fall lifeboat to have 11 10,000KJ food rations and 69 liters of water on-board. Replace food and water rations as per LSA requirement prior to departure from port. SOLAS 74 (14) Cons. III/20.2; LSA 4.4.8 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2018
Resolution: Received, reviewed and accepted proper documentation from [name withheld] stating the deficiency was rectified. The vessel's Master provided a photo and reciept showing the purchase of 7.5L emergency drinking water rations and 16 emergency food rations.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.