← All vessels
MATSON MAGNOLIA
MATSON MAGNOLIA is a 2006 freight ship. The Coast Guard has recorded 13 inspections since 2008, most recently in April 2026, along with 21 deficiencies and 2 operational controls.
Records from 2008 to 2026. Most recent: inspection, 28 April 2026.
- Built
- 2006
- Last inspected
- 28 April 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 21 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9302578 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5BRZ6
990674
Flag
CYPRUS
—
Maury page id
psix-990674
Inspections, by type
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it54586 - Convention (Subpart B), Gross Ton
68165 - Dead Weight, Metric Ton
88301 - Displacement, Metric Ton
31226 - Convention (Subpart B), Net Ton
68165 - Dead Weight, Metric Ton
88301 - Displacement, Metric Ton
31226 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
28 April 2026
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8357589
18 March 2026
PSC B · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8328231
17 September 2025
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8230618
6 April 2025
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8105985
14 January 2025
MARPOL Annex I Examination · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8063371
17 February 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7637659
13 January 2023
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7620990
7 January 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7617898
20 July 2021
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7261939
29 November 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6311631
7 October 2015
Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5737309
20 November 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3365949
20 November 2008
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3366093
Deficiency record · 21
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 March 2026
Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED CO2 FIRE EXTINGUISHING SYSTEM RELEASE CONTROL CABINET IN CO2 ROOM BROKEN AND DISMOUNTED WITH PILOT BOTTLES ON THE DECK AND COPPER SERVICE LINE SEVERED. 74 SOLAS (2004 Cons) II-2/14.2.1.2
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 21 March 2026
Resolved
THE ARRANGEMENT OF PIPES AND HYDRANTS SHALL BE SUCH AS TO AVOID THE POSSIBILITY OF FREEZING. DURING EMERGENCY FIRE PUMP TEST, PSCO OBSERVED THAT THE EMERGENCY FIRE PUMP STARTED AND WAS ABLE TO TAKE SUCTION AND PRESSURIZE THE DISCHARGE LINE, BUT THERE WAS NO WATER FLOW AT THE FIREFIGHTING STATIONS. ACCORDING TO THE SHIP'S CREW, THIS WAS DUE TO FROZEN WATER IN THE EMERGENCY FIRE PUMP DISCHARGE LINE BEFORE THE FIRE MAIN. 74 SOLAS (2004 Cons) II-2/10.2.1.1
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 March 2026
Resolved
FIRE ALARM SYSTEM SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS. WHILE TESTING A SMOKE DETECTOR, PSCO OBSERVED THAT AN ALARM PANEL IN THE FUEL OIL TRANSFER ROOM DID NOT MAKE AUDIBLE OR VISUAL ALARMS. 74 SOLAS (2004 Cons) II-2/14.2.1.1.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 January 2025
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed a severe leak from the HFO transfer pump with two buckets positioned under the leak. 74SOLAS(14) II-2/4.1.1
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 January 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fitting shall be of a design and construction adequate for the service for which they are intended. PSCO observed inoperable #1 lube oil purifier control panel and inoperable #3 HFO purifier control panel, rendering both purifiers inoperable. 74SOLAS(04) II-1/26
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 14 January 2025
Resolved
Oil filtering equipment shall be of a design approved by the Administration. Modifications of the OWS sampling line have been installed without proper administration approval. The modification included an isolation valve installed after the oil content meter. MARPOL 1/14/6
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 January 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed water-mist supply line isolation valve for the incinerator space in the closed position preventing automatic activation of water-mist supply to the incinerator space. 74 SOLAS(14) II-2/14.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 13 January 2023
Resolved
EFFICIENT GUARDRAILS SHALL BE FITTED TO ALL EXPOSED PARTS OF THE FREEBOARD AND SUPERSTRUCTURE DECKS. GUARDRAILS NEAR AFT CARGO WALKWAY WERE FOUND TO BE SEVERLY RUSTED, IMPACTING THEIR ABILITY TO BEAR WEIGHT OF CREW.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 January 2023
Resolved
ALL ACCESS OPENING SHALL BE FITTED WITH DOORS... THAT ARE WATERTIGHT WHEN CLOSED. DOOR ON PORT SIDE LEADING TO MUSTER AREA DID NOT CLOSE PROPERLY AND WAS MISSING PART OF GASKET
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 7 October 2015
Resolved
0715 Smoke extraction sample line 10 for cargo hold five aft and emergency power supply were in fault as indicated on the main alarm panel in the CO2 room. See activity 5737309 for full description. 74 SOLAS (2014)
II-2/7.2.2 30abc
Engineering › Steering Gear System › Power Unit
Issued 7 October 2015
Resolved
0936 Any main and auxiliary steering gear control system controllable from the navigation bridge shall in the event of a failure of electrical power supply to the control system, an audible and visual alarm shall be given on the navigation bridge. When the power was secured to the #1 or #2 pump an alarm was never activated on the bridge. 74 SOLAS (2004)
II-1/29.8.4 17ac
Engineering › Steering Gear System › Pump
Issued 7 October 2015
Resolved
0936 Audible and visual alarms shall be given on the navigation bridge and in the machinery space where they can be readily observed. Crew tested the low level hydraulic alarm and no alarm was given on the bridge or machinery space. 74 SOLAS (2004)
II-1/29.12.2 17ac
Engineering › Steering Gear System › Interlock
Issued 7 October 2015
Resolved
0950 While attempting to secure the power to the #2 steering pump the ships crew was unable to secure the breaker to the pump as designed. The local #2 steering gear panel is interlocked to secure the power to the 440 volt breaker before the panel can be opened. Due to a damaged breaker the panel must be opened while energized and tools were required to operate the broken breaker. 17ac
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2015
Resolved
0950 PSCO observed refer piping in overhead had ice build up that was steadily dripping onto the refer control electrical cabinet. In addition, electrical wires were in approximately six inches of standing water inside port side forward capstan. Crew did not know if the wires were energized. 74 SOLAS (04)
II-1/40.1.3 17ac
Engineering › Fuel Oil Service System › Flange
Issued 7 October 2015
Resolved
0999 Means shall be provided to control leaks of flammable liquids; A leak was found on the on a flange on the HFO overflow line in the way of HFO tank #4 starboard side tunnel. The lagging was saturated with fuel oil posing a fire hazard to the vessel. 74 SOLAS (2014)
II-2/4.1.1 17ac
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 7 October 2015
Resolved
0110 In every case the administration shall fully guarantee the completeness and deficiency of the inspection and survey, and shall undertake to ensure the necessary arrangements to satisfy this obligation. Life raft capacity does not meet Form E requirements. 74 SOLAS (2014)
I/6(d) 17ac
Documentation › Logs/Records › Oil Record Book
Issued 7 October 2015
Resolved
1710 The Oil Record Book shall be kept in such a place as to be readily available for inspection at all reasonable times and, except in the case of unmanned ships under tow, shall be kept on board the ship. It shall be preserved for a period of three years after the last entry has been made. Vessel only had an Oil Record Book starting in September 2015. MARPOL (2011)
Annex I Reg 17.6 40ac
Documentation › Logs/Records › Garbage Recordkeeping
Issued 7 October 2015
Resolved
2120 The Garbage Record Book shall be kept on board the ship and in such a place as to be available for inspection in a reasonable time. This document shall be preserved for a period of two years after the last entry is made on the record. Vessel only had a Garbage Record Book starting in September 2015. MARPOL (2011)
Annex V reg 9.3(c) 40ac
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 October 2015
Resolved
0750 The fire door to the engine room from the poop deck had a security screen locked in place preventing the crew from being able to readily secure the door in the event of a fire. Crew removed the security door. 74 SOLAS (2014)
II-2/10.4.2 10c
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 7 October 2015
Resolved
0715 The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. PSCO observed a fault for the galley smoke alarm on the fire control panels. The crew reset the fault returning the smoke alarm to operational status. 74 SOLAS (2014)
II-2/14.2.1.1.2 10c
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 October 2015
Resolved
2550 Due to the above objective evidence, the Captain of the Port questions the adequacy of the implementation of the vessel’s safety management system under the International Safety Management (ISM) code. During the full term SMC verification audit recommend paying particular attention to the above deficiencies. 74 SOLAS (2014) IX/3.1 ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.