MATSON MAGNOLIA

MATSON MAGNOLIA is a 2006 freight ship. The Coast Guard has recorded 13 inspections since 2008, most recently in April 2026, along with 21 deficiencies and 2 operational controls.

Records from 2008 to 2026. Most recent: inspection, 28 April 2026.

Built
2006
Last inspected
28 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9302578 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
990674
Flag
CYPRUS
—
Maury page id
psix-990674

Inspections, by type

…with no type recorded2
Years with a record 7 calendar years (2008–2026)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it54586 - Convention (Subpart B), Gross Ton
68165 - Dead Weight, Metric Ton
88301 - Displacement, Metric Ton
31226 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

28 April 2026 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8357589
18 March 2026 PSC B · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8328231
17 September 2025 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8230618
6 April 2025 PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8105985
14 January 2025 MARPOL Annex I Examination · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8063371
17 February 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7637659
13 January 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7620990
7 January 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7617898
20 July 2021 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7261939
29 November 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6311631
7 October 2015 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5737309
20 November 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3365949
20 November 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3366093

Deficiency record · 21

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 March 2026 Resolved
FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED CO2 FIRE EXTINGUISHING SYSTEM RELEASE CONTROL CABINET IN CO2 ROOM BROKEN AND DISMOUNTED WITH PILOT BOTTLES ON THE DECK AND COPPER SERVICE LINE SEVERED. 74 SOLAS (2004 Cons) II-2/14.2.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 March 2026
Resolved 29 April 2026
Resolution: The broken Fixed CO2 system control cabinet was renewed with spare by the crew. Visual inspection and alarm test were carried out in good order.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 21 March 2026 Resolved
THE ARRANGEMENT OF PIPES AND HYDRANTS SHALL BE SUCH AS TO AVOID THE POSSIBILITY OF FREEZING. DURING EMERGENCY FIRE PUMP TEST, PSCO OBSERVED THAT THE EMERGENCY FIRE PUMP STARTED AND WAS ABLE TO TAKE SUCTION AND PRESSURIZE THE DISCHARGE LINE, BUT THERE WAS NO WATER FLOW AT THE FIREFIGHTING STATIONS. ACCORDING TO THE SHIP'S CREW, THIS WAS DUE TO FROZEN WATER IN THE EMERGENCY FIRE PUMP DISCHARGE LINE BEFORE THE FIRE MAIN. 74 SOLAS (2004 Cons) II-2/10.2.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 March 2026
Resolved 29 April 2026
Resolution: Completely drained all fire lines on deck to avoid the water being frozen and to ensure proper operation of emergency fire pump. Main/Emergency fire pumps fire water shooting test were carried out in good order. The Main fire line drain line was inspecte
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 March 2026 Resolved
FIRE ALARM SYSTEM SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS. WHILE TESTING A SMOKE DETECTOR, PSCO OBSERVED THAT AN ALARM PANEL IN THE FUEL OIL TRANSFER ROOM DID NOT MAKE AUDIBLE OR VISUAL ALARMS. 74 SOLAS (2004 Cons) II-2/14.2.1.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 March 2026
Resolved 29 April 2026
Resolution: Signal light alarm panel in fuel transfer room was fixed by replacing burn parts with ready spare parts. The smoke detector alarm test was satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 January 2025 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed a severe leak from the HFO transfer pump with two buckets positioned under the leak. 74SOLAS(14) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2025
Resolved 16 January 2025
Resolution: PSCO received RINA class report attesting to proper repair and operation of HFO transfer pump. **See Document tab**
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 January 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fitting shall be of a design and construction adequate for the service for which they are intended. PSCO observed inoperable #1 lube oil purifier control panel and inoperable #3 HFO purifier control panel, rendering both purifiers inoperable. 74SOLAS(04) II-1/26
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2025
Resolved 16 January 2025
Resolution: PSCO received RINA class report attesting to proper repair and operation of #1 lube oil purifier control panel and #3 HFO purifier control panel. **See Document tab**
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 14 January 2025 Resolved
Oil filtering equipment shall be of a design approved by the Administration. Modifications of the OWS sampling line have been installed without proper administration approval. The modification included an isolation valve installed after the oil content meter. MARPOL 1/14/6
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2025
Resolved 16 January 2025
Resolution: PSCO received RINA class report attesting to proper removal of isolation valve on OWS after oil content meter. **See Document tab**
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 January 2025 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed water-mist supply line isolation valve for the incinerator space in the closed position preventing automatic activation of water-mist supply to the incinerator space. 74 SOLAS(14) II-2/14.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 January 2025
Resolved 16 January 2025
Resolution: Witnessed opening of isolation valve for wter-mist supply line for the incinerator space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 13 January 2023 Resolved
EFFICIENT GUARDRAILS SHALL BE FITTED TO ALL EXPOSED PARTS OF THE FREEBOARD AND SUPERSTRUCTURE DECKS. GUARDRAILS NEAR AFT CARGO WALKWAY WERE FOUND TO BE SEVERLY RUSTED, IMPACTING THEIR ABILITY TO BEAR WEIGHT OF CREW.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2023
Resolved 17 February 2023
Resolution: Vessel replaced the guard rails that were deemed unsafe. Class, as well as PSC in Sector Jacksonville assessed the guard rails. Issue resolved
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 January 2023 Resolved
ALL ACCESS OPENING SHALL BE FITTED WITH DOORS... THAT ARE WATERTIGHT WHEN CLOSED. DOOR ON PORT SIDE LEADING TO MUSTER AREA DID NOT CLOSE PROPERLY AND WAS MISSING PART OF GASKET
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2023
Resolved 17 February 2023
Resolution: PSCO witnessed and inspected door and gasket after reviewing class report. Vessel replaced the striker plate as well as gasket for the weather tight door.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 7 October 2015 Resolved
0715 Smoke extraction sample line 10 for cargo hold five aft and emergency power supply were in fault as indicated on the main alarm panel in the CO2 room. See activity 5737309 for full description. 74 SOLAS (2014) II-2/7.2.2 30abc
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 October 2015
Resolved 8 October 2015
Resolution: It was verified that the smoke detection repeater panel on the bridge was connected and showing normal operation. System was tested and found to be operating normally. Test was considered to be satisfactory to the attending class surveyor.
Engineering › Steering Gear System › Power Unit
Issued 7 October 2015 Resolved
0936 Any main and auxiliary steering gear control system controllable from the navigation bridge shall in the event of a failure of electrical power supply to the control system, an audible and visual alarm shall be given on the navigation bridge. When the power was secured to the #1 or #2 pump an alarm was never activated on the bridge. 74 SOLAS (2004) II-1/29.8.4 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2015
Resolved 8 October 2015
Resolution: Class has addressed issue to satisfaction of USCG
Engineering › Steering Gear System › Pump
Issued 7 October 2015 Resolved
0936 Audible and visual alarms shall be given on the navigation bridge and in the machinery space where they can be readily observed. Crew tested the low level hydraulic alarm and no alarm was given on the bridge or machinery space. 74 SOLAS (2004) II-1/29.12.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2015
Resolved 8 October 2015
Resolution: It was verified that both the hydraulic fluid tank alarms were tested and found operating satisfactorily in engine room as well as on the wheel house.
Engineering › Steering Gear System › Interlock
Issued 7 October 2015 Resolved
0950 While attempting to secure the power to the #2 steering pump the ships crew was unable to secure the breaker to the pump as designed. The local #2 steering gear panel is interlocked to secure the power to the 440 volt breaker before the panel can be opened. Due to a damaged breaker the panel must be opened while energized and tools were required to operate the broken breaker. 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2015
Resolved 8 October 2015
Resolution: The above noted damaged #2 steering pump breaker was replaced from OEM parts, operationally tested and considered satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2015 Resolved
0950 PSCO observed refer piping in overhead had ice build up that was steadily dripping onto the refer control electrical cabinet. In addition, electrical wires were in approximately six inches of standing water inside port side forward capstan. Crew did not know if the wires were energized. 74 SOLAS (04) II-1/40.1.3 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2015
Resolved 8 October 2015
Resolution: Class has addressed issue to satisfaction of USCG
Engineering › Fuel Oil Service System › Flange
Issued 7 October 2015 Resolved
0999 Means shall be provided to control leaks of flammable liquids; A leak was found on the on a flange on the HFO overflow line in the way of HFO tank #4 starboard side tunnel. The lagging was saturated with fuel oil posing a fire hazard to the vessel. 74 SOLAS (2014) II-2/4.1.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2015
Resolved 8 October 2015
Resolution: The above noted loose flange was tightened and the leakage rectified. The oil stained lagging was replaced with new lagging. The repair was examined and considered satisfactory.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 7 October 2015 Resolved
0110 In every case the administration shall fully guarantee the completeness and deficiency of the inspection and survey, and shall undertake to ensure the necessary arrangements to satisfy this obligation. Life raft capacity does not meet Form E requirements. 74 SOLAS (2014) I/6(d) 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2015
Resolved 8 October 2015
Resolution: A new Form E has been issued to reflect the correct capacity of sixy four (64) persons for the four (4) life rafts onboard the vessel. A new full term Cargo Ship Safety Equipment Certificate valid until 25 June 2016 has been issued to reflect new Form E,
Documentation › Logs/Records › Oil Record Book
Issued 7 October 2015 Resolved
1710 The Oil Record Book shall be kept in such a place as to be readily available for inspection at all reasonable times and, except in the case of unmanned ships under tow, shall be kept on board the ship. It shall be preserved for a period of three years after the last entry has been made. Vessel only had an Oil Record Book starting in September 2015. MARPOL (2011) Annex I Reg 17.6 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 October 2015
Resolved 8 October 2015
Resolution: Class has addressed issue to satisfaction of USCG
Documentation › Logs/Records › Garbage Recordkeeping
Issued 7 October 2015 Resolved
2120 The Garbage Record Book shall be kept on board the ship and in such a place as to be available for inspection in a reasonable time. This document shall be preserved for a period of two years after the last entry is made on the record. Vessel only had a Garbage Record Book starting in September 2015. MARPOL (2011) Annex V reg 9.3(c) 40ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 October 2015
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 October 2015 Resolved
0750 The fire door to the engine room from the poop deck had a security screen locked in place preventing the crew from being able to readily secure the door in the event of a fire. Crew removed the security door. 74 SOLAS (2014) II-2/10.4.2 10c
Condition: Improper Installation
Due 7 October 2015
Resolved 7 October 2015
Resolution: Crew removed security door.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 7 October 2015 Resolved
0715 The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. PSCO observed a fault for the galley smoke alarm on the fire control panels. The crew reset the fault returning the smoke alarm to operational status. 74 SOLAS (2014) II-2/14.2.1.1.2 10c
Condition: Improper/Lack of Maintenance
Due 7 October 2015
Resolved 7 October 2015
Resolution: The crew reset the fault returning the smoke alarm to operational status.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 October 2015 Resolved
2550 Due to the above objective evidence, the Captain of the Port questions the adequacy of the implementation of the vessel’s safety management system under the International Safety Management (ISM) code. During the full term SMC verification audit recommend paying particular attention to the above deficiencies. 74 SOLAS (2014) IX/3.1 ac
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 March 2016
Resolved 8 October 2015
Resolution: Class has addressed issue to satisfaction of USCG