HORIZON ARMONIA is a 2008 tank ship. The Coast Guard has recorded 19 inspections since 2008, most recently in May 2026, along with 6 deficiencies — 2 with no resolution recorded — and 6 operational controls.

Records from 2008 to 2026. Most recent: inspection, 4 May 2026.

Built
2008
Last inspected
4 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9407354 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
990721
Flag
LIBERIA
—
Maury page id
psix-990721

Inspections, by type

…with no type recorded7
Years with a record 10 calendar years (2008–2026)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29828 - Convention (Subpart B), Gross Ton
50327 - Dead Weight, Metric Ton
60644 - Displacement, Metric Ton
13429 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

4 May 2026 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8361295
11 October 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8017992
22 December 2023 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7841799
10 December 2023 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7839532
9 December 2023 COC-CHEM & TVE Renew · COE-Administrative · PSC B
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7836176
28 June 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7489858
19 April 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7430765
6 July 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6993741
30 September 2018 COE-Offshore · Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6549506
18 March 2014 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4817261
19 July 2012 PI Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4383753
19 July 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4384473
18 July 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4380832
18 July 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4383702
19 November 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3894947
10 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3889071
9 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4255206
31 October 2010 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3876412
24 November 2008 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3368325

Deficiency record · 6

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2026 No resolution recorded
In tankers, electrical equipment, cables, and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those accepted by the organization. PSCO observed starboard side ESD cableing exposed and not longer explosion proof. 74 SOLAS II-1/45.11 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 14 October 2024 No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel had a failure of the remote engine control system while enroute to Port of New York and New Jersey. Vessel was unable to carry out repairs on Maine Engine governer while in the Port of New York and New Jersey. 74 SOLAS (20) I/11(a) 40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Lifeboat Equipment › Food Ration
Issued 18 March 2014 Resolved
Food rations shall be vacuum packed. Found 20 packages between port and starboard lifeboat which were not vacuum sealed. SOLAS 09 CH III Reg. 34 LSA Code Ch IV 4.1.5.1.18
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2014
Resolved 19 March 2014
Resolution: Received invoice from Liferafts Inc. Puerto Rico for the purchase of the 20 food rations.
Engineering › Steering Gear System › Piping
Issued 18 March 2014 Resolved
All steering gear components and rudder stock shall be sound and reliable construction. The fresh water piping system that cools this steering system's hydraulic fluid has excessive soft paces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2014
Resolved 20 March 2014
Resolution: ABS Class issued a condition of Class. See attach document.
Engineering › Steering Gear System › Power Unit
Issued 19 July 2012 Resolved
0936-Steering- Every ship shall be provided with a main steering gear to the satisfaction of the Administration. While transiting upriver the vessel experienced a steering loss due to phase failure of #2 steering gear caused by disconnected power cable in #2 steering gear distribution panel. SOLAS 74(am) II-1/29.
Action required: 705 - Other - as specified
Due 19 July 2012
Resolved 19 July 2012
Resolution: Reviewed, recieved, accepted class report from ABS attesting to the proper operation of the steering gear and all components pertaining to the steering casualty. Verified all cables and connections are tight and in good working order.
Construction/Loadline › Hull › Bottom Plating
Issued 19 November 2010 Resolved
Vessel experienced a grounding while operating in the Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2010
Resolved 19 November 2010
Resolution: Received, reviewed, and accepted class report from ABS stating the hull was examined and no signs of damage was noted.

Ownership record