Records from 2008 to 2021. Most recent: inspection, 14 May 2021.
Documentation record
Registered dimensions (L × B × D)33.0 ft × 10.0 ft × 5.0 ft
Registered tonnagegross 11 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYNCH'S BOAT MFG INC · LAKE HAVASU CITY, AZ, UNITED STATES · built 2007
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPOUGH, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
14 May 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7197016
15 August 2018
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6511782
21 June 2017
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6293042
29 June 2016
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5925163
3 June 2008
Plan Review "T" Boat · Construction Oversight · Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3364572
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 15 August 2018
Resolved
Each passenger ship transporting more than six passengers for hire equipped with a radiotelephone that does not exceed 250 watts, that operator must hold a marine radio operator permit. Operator must furnish marine radio operators permit. 47 CFR 80.159(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 18 October 2018
Resolution: Cleared via picture of test results for license.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 August 2018
Resolved
The employer shall provide an Employee Assistance Program for all crew members and display informational material, assistance hot lines, and company drug policy. The operator must furnish drug policy, hot line numbers, and informational material for display. 46 CFR 16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 17 September 2018
Resolution: Resolved via emailed pictures of posted drug policy on vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 August 2018
Resolved
A vessel must carry a first aid kit approved under approval series 160.041 or an equivalent kit. Several items in the kit were expired and must be replaced. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 4 September 2018
Resolution: Pictures of new medical supplies submitted via email.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 August 2018
Resolved
Inspection and maintenance of equipment shall be logged or otherwise documented. Operator instructed on type of log keeping. 46 CFR 185.702
Action required: 10 - Deficiency Rectified
Resolved 15 August 2018
Resolution: Operator instructed on types of entries that should be in log book. Operator had been keeping some records, but will consolidate what they have and keep more robust records.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 June 2016
Resolved
Provide valid COD.
Due 29 July 2016
Resolved 16 August 2016
Resolution: Received prood of COD.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 29 June 2016
Resolved
Provide valid FCC safety license.
Due 29 July 2016
Resolved 16 August 2016
Resolution: Received valid FCC cert.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 29 June 2016
Resolved
Provide proper operation of fireboy override test.
Due 29 July 2016
Resolved 4 August 2016
Resolution: Vsl rep able to operate override and shut down.
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 June 2016
Resolved
Conduct drills and record in log book.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2016
Resolution: Provided proof of drills.