PORT MACAU

PORT MACAU is a 2006 freight ship. The Coast Guard has recorded 13 inspections since 2008, most recently in November 2023, along with 9 deficiencies and 3 operational controls.

Records from 2008 to 2023. Most recent: inspection, 20 November 2023.

Built
2006
Last inspected
20 November 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9423475 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A2145
990985
Flag
MARSHALL ISLANDS
—
Maury page id
psix-990985

Inspections, by type

…with no type recorded3
Years with a record 8 calendar years (2008–2023)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it32415 - Convention (Subpart B), Gross Ton
58730 - Dead Weight, Metric Ton
67814 - Displacement, Metric Ton
19353 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

20 November 2023 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7827466
23 October 2023 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7813080
23 September 2019 ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6818489
18 September 2019 MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6814621
11 March 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6102991
2 March 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6091448
8 March 2014 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4806709
22 September 2011 PII Safety Exam · ISPS I Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4146829
21 September 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4146913
30 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3901086
13 November 2010 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3888010
10 December 2009 MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3644624
4 December 2008 MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3370541

Deficiency record · 9

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2019 Resolved
The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and enviormental conditions on board. Temporary repair and leak found on raw water supply pipe to CFW cooler, lower level. 74SOLAS(04 Cons) II-1 26.1 60ac
Action required: 60 - Rectify deficiencies prior to movement
Due 20 September 2019
Resolved 21 September 2019
Resolution: Crew made repairs to leaks, ABS attended vessel to attest to satisfaction of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2019 Resolved
The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and enviormental conditions on board. Found pinhole leak on fire main pipe IVO the forward engine room bulkhead, lower level. 74SOLAS(04Cons) II-1 26.1 60ac ABS issued dispensation for issue, extending deadline for 90 days.
Action required: 60 - Rectify deficiencies prior to movement
Due 20 September 2019
Resolved 29 December 2020
Resolution: Class provided a report of survey confirming rectification of deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2019 Resolved
Every steam pipe and every fitting connected there to through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stress to which it may be subjected. Found steam line leaking at flange IVO the forward engine room bulkhead on the lower level. 74SOLAS(04Cons) II-1 33.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2019
Resolved 21 September 2019
Resolution: Flange bolts replaced and flange cleaned to satisfaction of ABS attending surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 September 2019 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirments must be met; means shall be provided to control leaks of flammable liquids. Found oil soaked lagging on piping below oil purifier space and on piping below generators. 74SOLAS(04Cons) II-2 4.1.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2019
Resolved 21 September 2019
Resolution: Lagging and area cleaned to the satisfaction of attending ABS surveyor..
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2019 Resolved
The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and enviormental conditions on board. Found raw water pipe IVO engine room bulkhead severly corroded at flange. 74SOLAS(04Cons) II-1 26.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2019
Resolved 21 September 2019
Resolution: Weld on pipe found to be faulty. Weld corrected and hydrostatically tested by approved welder, to the satisfaction of attending ABS surveyor.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 18 September 2019 Resolved
In accordance with the vessels safety managment system, vessels crew did not report the following repairs/deficiencies: temporary repair on raw water pipe to CFW cooler, leak in steam pipe approx. one year old, leak in fire main IVO E/R forward bulkhead. 74SOLAS(04Cons) IX Reg. 5 ISM Code 2018 Part A 10.2.2 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2019
Resolved 21 September 2019
Resolution: Vessel's Master generated SMS Non-Conformity Report and made corrective actions in line with ISM.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 2 March 2017 Resolved
0750-Fire Prevention- MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. [name withheld] OF FUEL COMING FROM AROUND HFO SETTLING TANK. PSCO FOUND SATURATED PIPE LAGGING COMING OFF TANK VAPOR COLLECTION LINE. SOLAS 14 II-2/4.1.1 - 16a
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 11 March 2017
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.
Navigation › Collision/Grounding Avoidance › Radar
Issued 24 November 2010 Resolved
The radar was reported not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 November 2010
Resolved 28 November 2010
Resolution: Received, reviewed and accepted tech report stating that the radar was repaired, tested and found satisfactory.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 10 December 2009 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 10 December 2009
Resolved 14 December 2009
Resolution: Recieved proof of reciept of valid Flag State Endorsements for all crew in question.

Ownership record