Records from 2017 to 2023. Most recent: inspection, 20 November 2023.
Inspection history · 6
20 November 2023
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7827466
23 October 2023
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7813080
23 September 2019
ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6818489
18 September 2019
MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6814621
11 March 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6102991
2 March 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6091448
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2019
Resolved
The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and enviormental conditions on board. Temporary repair and leak found on raw water supply pipe to CFW cooler, lower level. 74SOLAS(04 Cons) II-1 26.1 60ac
Action required: 60 - Rectify deficiencies prior to movement
Due 20 September 2019
Resolved 21 September 2019
Resolution: Crew made repairs to leaks, ABS attended vessel to attest to satisfaction of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2019
Resolved
The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and enviormental conditions on board. Found pinhole leak on fire main pipe IVO the forward engine room bulkhead, lower level. 74SOLAS(04Cons) II-1 26.1 60ac
ABS issued dispensation for issue, extending deadline for 90 days.
Action required: 60 - Rectify deficiencies prior to movement
Due 20 September 2019
Resolved 29 December 2020
Resolution: Class provided a report of survey confirming rectification of deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2019
Resolved
Every steam pipe and every fitting connected there to through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stress to which it may be subjected. Found steam line leaking at flange IVO the forward engine room bulkhead on the lower level.
74SOLAS(04Cons) II-1 33.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2019
Resolved 21 September 2019
Resolution: Flange bolts replaced and flange cleaned to satisfaction of ABS attending surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 September 2019
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirments must be met; means shall be provided to control leaks of flammable liquids. Found oil soaked lagging on piping below oil purifier space and on piping below generators. 74SOLAS(04Cons) II-2 4.1.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2019
Resolved 21 September 2019
Resolution: Lagging and area cleaned to the satisfaction of attending ABS surveyor..
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2019
Resolved
The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and enviormental conditions on board. Found raw water pipe IVO engine room bulkhead severly corroded at flange. 74SOLAS(04Cons) II-1 26.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2019
Resolved 21 September 2019
Resolution: Weld on pipe found to be faulty. Weld corrected and hydrostatically tested by approved welder, to the satisfaction of attending ABS surveyor.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 18 September 2019
Resolved
In accordance with the vessels safety managment system, vessels crew did not report the following repairs/deficiencies: temporary repair on raw water pipe to CFW cooler, leak in steam pipe approx. one year old, leak in fire main IVO E/R forward bulkhead. 74SOLAS(04Cons) IX Reg. 5
ISM Code 2018 Part A 10.2.2 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2019
Resolved 21 September 2019
Resolution: Vessel's Master generated SMS Non-Conformity Report and made corrective actions in line with ISM.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 2 March 2017
Resolved
0750-Fire Prevention- MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. [name withheld] OF FUEL COMING FROM AROUND HFO SETTLING TANK. PSCO FOUND SATURATED PIPE LAGGING COMING OFF TANK VAPOR COLLECTION LINE. SOLAS 14 II-2/4.1.1 - 16a
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 11 March 2017
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.