HOKU is a 2008 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in April 2026, along with 25 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 29 April 2026.

Built
2008
Last inspected
29 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE7019
991094
Flag
UNITED STATES
Maury page id
psix-991094

Documentation record

Registered dimensions (L × B × D)37.1 ft × 13.2 ft × 6.1 ft
Registered tonnagegross 20 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNAIAD INFLATABLES OF NEWPORT · PORTSMOUTH, RI, UNITED STATES · built 2008
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

14 inspections, each with its date, unit and type; 25 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

29 April 2026 Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8358279
24 April 2025 Drydock Exam · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8121959
17 April 2024 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7896614
13 April 2023 Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7667663
29 July 2022 DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7519797
7 June 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7471144
10 November 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7348470
7 April 2021 Drydock Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7169333
2 July 2020 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6993766
19 March 2020 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6929670
17 April 2019 Drydock Exam · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6664991
25 April 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6399591
26 April 2017 Annual Inspection · DAPI Audit · Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6134793
23 April 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5886133

Deficiency record · 25

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 02 Marlin Type 1 life jackets installed on vessel (Model 320RT for Adults and Model 321RT for Child size) have a malfunctioning spring-loaded tab on the snap hook of the safety strap. The spring-loaded tabs fail to spring back,(return to closed position) after depressing to secure snap hook in place. Renewal required for all affected Lot #'s. Vessel has 21 serviceable adult life jackets on board, therefore passenger count shall be reduced to 19 passengers + 02 required crew, until affected life jackets are replaced with serviceable Type 1 life jackets. 46 CFR 176.808(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2026
Resolved 16 July 2026
Resolution: New Type 1 jackets installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2026 Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10 for annual maintenance and recharging of extinguishers. Owner must provide satisfactory evidence of the required servicing to the marine inspector. Portable fire extinguishers installed on vessel expire the annual servicing requirements on 01May2026. Provide annual servicing records no later than 01May2026. Failure to meet servicing requirements will result in prohibiting the vessel to operate while carrying passengers. 46 CFR 176.810(b)(1)(2)
Action required: 705 - Other - as specified
Due 1 May 2026
Resolved 1 May 2026
Resolution: Fire bottle servicing completed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 April 2023 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked "First-Aid Kit". A first-aid kit must be easily visible and readily available to the crew. First aid kit is incomplete. Provide USCG-approved kit or a kit that complies with the list in 46 CFR 160.041. 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2023
Resolved 24 April 2023
Resolution: New first aid kit provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 April 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2023
Resolved 24 April 2023
Resolution: Updated nav pubs provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 April 2023 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke signals. A red hand flare distress signal may be substituted for any of the hand orange smoke distress signals. Vessel's hand orange smoke distress signals are expired. Vessel has eight red hand flare distress signals and is required to have 4 hand orange smoke signals in order to meet the regulation. Vessel restricted to a Lakes/Bays/Sounds route or 30 min runs. 46 CFR 180.68
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2023
Resolved 24 April 2023
Resolution: Proper amount of flares provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 April 2023 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Life ring buoys on board vessel has worn Type II retroreflective material. Add/replace retroreflective type material on life ring bouy. 46 CFR 185.604(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2023
Resolved 24 April 2023
Resolution: Retro tape provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 April 2023 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Several life jackets had worn appropriate retroreflective material. Provide appropriate markings to the satisfaction of the attending marine inspector. 46 CFR 185.604(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2023
Resolved 24 April 2023
Resolution: Retro tape provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 July 2022 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Personnel in supervisory position has not received supervisory training. Provide proof of completed EAP training for all supervisory personnel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2022
Resolved 9 August 2022
Resolution: Supervisory personnel provided proof of training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 June 2022 Resolved
A flammable vapor detection system must provide a visual and audible alarm at the operating station. The flammable vapor detector in the enclosed space that holds the gasoline tank is inoperable. Repair or replace flammable vapor detector. 46CFR182.480(d)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2022
Resolution: New flammable detector provided.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 7 June 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The first-aid kit is expired. Replace expired medication. 46CFR184.710
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 7 July 2022
Resolution: New first aid kit provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 June 2022 Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. The life float is not marked on both sides with the maximum capacity or the vessel’s name. Properly mark the life float. 46CFR185.604(e)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 7 July 2022
Resolution: Life float properly marked with capacity and vessel name.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 June 2022 Resolved
A red warning sign at the switch must state that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one complete change of air in the space served. The warning sign is not red. Replace with correct warning sign. 46CFR182.460(e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 7 July 2022
Resolution: Red warning sign provided.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 June 2022 Resolved
Employers must ensure that they and their crewmembers meet the requirements of this part. The employer has failed to fully implement a drug and alcohol testing program as required by 46CFR16. A DAPI audit is required. 46CFR16.203(a)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 7 July 2022
Resolution: DAPI audit scheduled.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 June 2022 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. The vessel’s stern navigation light is extinguished. Vessel is restricted to daytime operations only. 46CFR183.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 July 2022
Resolution: Operational nav lights provided.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 7 June 2022 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2), except that a VHF radiotelephone installation without DSC capability is permitted until one year after the Coast Guard notifies the Commission that shore-based sea area A1 coverage is established. Vessels in this category must not operate more than 20 nautical miles from land. The vessel’s VHF radio is inoperable. Vessel is shall not operate more than 1,000 feet from shore. 47CFR80.905(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 June 2022
Resolution: Cable from VHF to antenna replaced. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 7 April 2021 Resolved
EPIRB battery expired. Provide valid EPIRB battery.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2021
Resolution: New EPIRB provided with NOAA registration.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 April 2021 Resolved
Bilge high water alarm visual and audible not operational. Provide working bilge visual and audible high water alarms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2021
Resolution: New bilge high water alarms provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 April 2021 Resolved
Automatic bilge pump did not have light indicating operation at the helm. Provide automatic bilge pump light when pump is operating at the helm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2021
Resolution: New auto bilge light indicator provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 April 2021 Resolved
Navigation stern light not operational. Provide operational navigation stern light. Prior to night time ops.
Action required: 705 - Other - as specified
Resolved 28 April 2021
Resolution: Light operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2021 Resolved
Speaker wire used as electrical conductor. Remove speaker wire and replace with proper electrical conductor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 7 April 2021
Resolution: Speaker wire removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 April 2021 Resolved
Gasoline fuel tank space blower did not have sign stating time to be operated prior to stating engine at helm. Ventilation of spaces containing fuel tanks for gasoline must meet table in 182.460. Measure space, provide proper signage, and ensure interlock starts blower before engine starter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 28 April 2021
Resolution: Signage provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 March 2020 Resolved
4 red flares were missing. Provide in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2020
Resolved 2 July 2020
Resolution: 4 red flares provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 March 2020 Resolved
Lifefloat covering was unsatisfactory. Repair/renew in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2020
Resolved 2 July 2020
Resolution: Lifefloat repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 March 2020 Resolved
Fuel supply lines from tank to filter were unsatisfactory. Renew lines in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2020
Resolved 2 July 2020
Resolution: Fuel supply lines renewed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 March 2020 Resolved
Radio Safety Certificate was expired. Provide in accordance with 46 CFR 184.502.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2020
Resolved 2 July 2020
Resolution: Radio Safety Certificate provided.

Ownership record