MAURY USCG vessel records
← All vessels

CSC AUSPICIOUS

CSC AUSPICIOUS is a tank ship. The Coast Guard has recorded 7 inspections since 2016, most recently in January 2025, along with 2 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 24 January 2025.

Built
Not recorded
Last inspected
24 January 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 January 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9406374
991943
Flag
HONG KONG
Maury page id
psix-991943

Documentation record

Tonnage as PSIX records it29593 - Simplified, Gross Ton
29593 - Convention (Subpart B), Gross Ton
12466 - Simplified, Net Ton
45851 - Dead Weight, Ton
57669 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

24 January 2025 COC-TVE Renew · PSC B
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 8069253
10 March 2023 PSC B · COC-TVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7646615
26 December 2021 PSC B · COC-TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7372419
27 August 2018 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6523797
6 August 2018 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6498463
1 September 2016 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 5993901
19 August 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5977635

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 6 August 2018 Resolved
Fire fighters outfit shall consist of protective clothing material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. During the fire drill PSCO observed two fire fighting outfits with torn and wasted protective material under the arms and along the heels. SOLAS74(04 CONS)II-2/10.1 / FSS Code CH.3.2.1.1.1 - 10c (corrected on spot)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 August 2018
Resolution: Vessel removed the two worn fire fighting outfits from service and replaced with two new sets already on board.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 August 2018 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter diameter and is at least 25.4 millimeters long. PSCO found all vapor connection flanges without permanent studs. 46CFR.2001(j) - 40a/c
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 August 2018
Resolution: Received Class Survey Report of corrected vapor flange studs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.