MAURY USCG vessel records
← All vessels

KIRBY 11528

Built
2009
Last inspected
4 March 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 4 March 2024
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 14 calendar years (2009–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

991959
Flag
UNITED STATES
Maury page id
psix-991959

Documentation record

Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2009
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 22 January 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton
735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT. W. D. NUNLEY Towing Vessel · MISLE 1055286 · 1 April 2014 · activity 5084971

Inspection history · 16

4 March 2024 Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7873722
30 March 2021 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7165104
10 April 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6938029
29 January 2019 Drydock Exam · COI Inspection · Internal Structural Exam · Examination of Repairs · Cargo Tank Internal · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6616966
6 April 2018 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6389059
14 March 2017 Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6105464
13 April 2016 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5852361
8 April 2015 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5099574
1 April 2014 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5084971
7 January 2014 Examination of Repairs · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4776496
18 July 2013 Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4654261
17 September 2012 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4443438
15 June 2012 MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4347516
6 July 2011 Annual Inspection · Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4071424
11 June 2010 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3762949
23 March 2009 Cargo Tank Internal · Internal Structural Exam · Hull Examination · Initial Certification · MTSA Verification · Initial Construction-Excluding Oversight
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3464574

Deficiency record · 5

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 January 2019 Resolved
For all vessels except those limited on their Certificate of Inspection to river routes only, the minimum midship section modulus must be at least 100 percent of that which is necessary to meet the bending moment developed under a full load condition in still water, using a permissible bending stress of 12.74 kN/cm^2 (1.30 t/cm^2, 8.25 Ltf/in^2). Inspector sighted bilge knuckle longitudinally for fairness, and discovered approximate 10' long x 4' section of bilge knuckle in way of the STBD side mid-body that has an obvious loss of radius on both the vertical and horizontal axis due to indentation, which severely reduces longitudinal strength. Conduct repairs to satisfaction of attending marine inspector, or provide analysis from Professional Engineer that proves longitudinal strength not affected and meets ABS standards for hull integrity.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 February 2019
Resolution: Attended vessel and conducted a 1.5 PSI air test in cargo void with no leaks noted.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 18 July 2013 Resolved
Prove close gauging (wipers) do not leak within 30 days. Vessel prohibited from carrying cargoes requiring VCS until inspected to the satisfaction of attending CG Marine Inspector. 46CFR39-20-3
Action required: 705 - Other - as specified
Due 18 August 2013
Resolved 29 July 2013
Resolution: Observed air test and no leaks detected.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 18 July 2013 Resolved
Place vapor line diagram in transfer procedures. 33CFR155.750
Action required: 705 - Other - as specified
Due 18 August 2013
Resolved 29 July 2013
Resolution: Observed vapor line diagram posted near cargo pump.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 18 July 2013 Resolved
Prove cargo hose FMT 353 has been tested IAW 33CFR156.170 33CFR156.170
Action required: 705 - Other - as specified
Due 25 July 2013
Resolved 31 July 2013
Resolution: Received scanned copy of satisfactory hose test record.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 July 2013 Resolved
Paint nav lights equip flat or matt black within 30 days to the satisfaction of the attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 18 August 2013
Resolved 29 July 2013
Resolution: Observed new paint.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.