← All vessels
CLAM
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southwest District (CGD-SW) · Other hulls named CLAM
CLAM is a 2008 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2008, most recently in April 2025, along with 49 deficiencies, 5 operational controls and 1 casualty investigation in 2018.
Records from 2008 to 2025. Most recent: inspection, 22 April 2025.
- Built
- 2008
- Last inspected
- 22 April 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 49 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2018
Identity
1217122
WDE9007
992038
Flag
UNITED STATES
—
Maury page id
psix-992038
Inspections, by type
…with no type recorded1
Years with a record
15 calendar years (2008–2025)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)61.2 ft × 21.3 ft × 7.2 ft
Registered tonnagegross 62 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALLEN MARINE INC · SITKA, AK, UNITED STATES · built 2008
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portTIBURON, CA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 29 April 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it62 - Simplified, Gross Ton
50 - Simplified, Net Ton
50 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
22 April 2025
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8116849
11 February 2025
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8076461
4 February 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8074787
3 July 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7947594
18 April 2023
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7670461
24 January 2023
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7624719
1 June 2022
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7464833
5 May 2021
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7188406
11 March 2021
Drydock Exam · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7153549
1 February 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7134191
20 August 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7037411
11 August 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7014598
3 September 2019
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6802465
31 January 2019
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6618278
27 June 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6457906
27 June 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6494466
29 May 2018
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6422898
22 December 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6327942
26 July 2017
Annual Inspection · Administrative Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6219569
16 February 2017
Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6089624
17 January 2017
Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6072335
25 May 2016
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5886476
5 March 2014
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4809156
16 May 2012
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4312544
28 January 2011
Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3935323
23 March 2009
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3438223
9 December 2008
Inclining Experiment · Construction Oversight · Deadweight Survey · Plan Review "T" Boat
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3377186
Deficiency record · 49
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 April 2025
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Marine Inspector identified a lack of alcohol testing devices on board (alcohol test swabs), in addition to the absence of an employee list indicating personnel enrolled in the on board Drug and Alcohol Program. Provide evidence of sufficient drug and alcohol testing devices, and of a comprehensive drug and alcohol program to the satisfaction of the Marine Inspector.
46 CFR 4.06-15(a)(1)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 April 2025
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Bottom of fire extinguisher bracket near fire hose station wasted. Conduct repairs to the satisfaction of the Marine Inspector.
46 CFR 181.520
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 April 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Marine Inspector identified that broken door latches on the port side vessel leading to the engine room and storage void. Conduct repairs to the satisfaction of the Marine Inspector.
46 CFR 177.100
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2025
Resolved
Each...ring life buoy must be marked with Type II retroreflective material...The arrangement...must be as specified by IMO Resolution A.658(16). Marine Inspector identified that the retroreflective material on the ring life buoy was weathered and peeling. Conduct repairs to the satisfaction of the Marine Inspector.
46 CFR 185.604(i)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 February 2025
Resolved
1) A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. The vessel has not completed a drydock examination within the last two years. Conduct satisfactory drydock examination prior to the carriage of passengers. 46 CFR 176.600(c)(1)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 3 July 2024
Resolved
A hatch cover must:Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. 03 hatches found to be missing chain attached to hatch, Laz port/stbd and stbd engine room hatch.
46 CFR 179.360(b)(2)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2024
Resolved
Electrical equipment on a vessel must be installed and
maintained to; protect passengers, crew, other persons
,and the vessel from electrical hazards, including fire
caused by or originating in electrical equipment, and
electrical shock. Missing outlet box cover in STBD side
main seating are.
46 CFR 183.200
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 3 July 2024
Resolved
A vessel under 46 CFR 175.110(c) requirements must conduct a training program to address firefighting proficiency,emergency egress and must include; Training in the use and location of firefighting equipment and general firefighting knowledge and egress for each membr.
46 CFR 185.420
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 July 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels who: Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. No records of random drug testing information was on board vessel.
46 CFR 16.230(a)(1)
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 18 April 2023
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: (1) Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Vessel is missing proof of enrollment in random drug testing procedures, personnel, and testing facilities. Provide enrollment and mandatory testing information satisfactory to Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 June 2022
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Starboard bilge pump in ballast tank space is inoperable.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 June 2022
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel operator could not produce certificate for servicing of pre-engineered fire extinguishing system.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 1 June 2022
Resolved
Each connection to a conductor must be made with an enclosure. Oil sump pumps on both propulsion engines found to be connected with twist method (starboard) and automotive connection (port). Reconnect conductors using marine grade connections that meet UL486A and utilize a heat shrink that insulates wiring as required for hazardous locations.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 1 June 2022
Resolved
Each battery must be secured to protect against shifting with roll and pitch of the vessel. Generator start battery found unsecured.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 1 June 2022
Resolved
Connections to battery terminals with permanent type connectors. Temporary type clamps are prohibited. Generator start battery has wing nut on positive terminal.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 June 2022
Resolved
A vessel must comply with the applicable requirements for any radio installation as set forth in 47 CFR part 80. Vessel has VHF DSC that has not been programmed with MMSI. Program MMSI into radio.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 June 2022
Resolved
A vessel must comply with the applicable requirements for any radio installations including requirements for installation certificates to be issued by the FCC as set forth in 47 CFR part 80. Vessel has expired radiotelephony certificate.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Marine Inspector found cardboard box placed near transformer creating a potential fire hazard. Operator removed during inspection.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 5 May 2021
Resolved
"On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level." 46 CFR 182.530
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 May 2021
Resolved
"Protect passengers, crew, other persons, and the vessel from electrical hazards." 46 CFR 183.200
Cover for electrical outlet in cabin.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 May 2021
Resolved
"The frame or support of each semi-portable fire extinguisher must be attached to a bulkhead or deck." 46 CFR 181.500
Install bracket onboard for extra fire extinguishers. Install before bringing extinguishers back on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2021
Resolved
"Each life jacket must be marked with Type I retroreflective material." 46 CFR 185.604
Apply new tape on two life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 5 May 2021
Resolved
"At each initial and subsequent inspection for certification the operator shall be prepared to test the steering systems of the vessel and make available for inspection to the extent necessary to determine that they are in sutiable condition and fit for the service intended." 46 CFR 176.814
Primary steering second nut to lock in, both port and starboard side.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 February 2021
Resolved
A vessel exposed to salt water more than three months in any 12 month period must undergo a drydock examination and internal structural exam at least once every two years. Operator did not make vessel available for January 2021 drydock.
46 CFR 176.600(c)(1)
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 August 2020
Resolved
A FIRE PUMP MUST BE ABLE TO WITHSTAND NO LESS THAN 189 LITERS (50 GALLONS) PER MINUTE AT A PRESSURE OF NOT LESS THAN 414 KPA (60 PSI) AT THE PUMP OUTLET. THE SEA VALVE WAS FOUND TO BE INEFFECTIVE RESULTING IN AN INOPERABLE FIRE PUMP.
46 CFR 181.300 (b)
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 20 August 2020
Resolved
A VESSEL MUST COMPLY WITH THE APPLICABLE REQUIREMENTS FOR ANY RADIO AND EPIRB INSTALLATIONS, INCLUDING THE REQUIREMENTS FOR A STATION LICENSE AND INSTALLATION CERTIFICATES TO BE ISSUED BY THE FCC, AS SET FORTH IN 47 CFR 80. DISCOVERED VESSEL'S FCC STATION & SAFETY LICENSES WERE EXPIRED.
46 CFR 184.502
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 August 2020
Resolved
EACH DISPOSABLE HYDROSTATIC RELEASE UNIT MUST BE MARKED WITH AN EXPIRATION DATE OF TWO YEARS AFTER THE DATE ON WHICH THE UNIT IS INSTALLED. DISCOVERED THAT THE DISPOSABLE HYDROSTATIC RELEASE UNIT ATTACHED TO THE VESSEL'S IBA EXPIRED.
46 CFR 185.740 (2)(b)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 August 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 20 August 2020
Resolved
WIRES AND CABLES SHOULD BE INSTALLED IN AN ORGANIZED MANNER WITH METAL SUPPORTS SPACED NOT MORE THAN 610 MILLIMETERS (24 INCHES) APART. DISCOVERED NUMEROUS INSUFFICIENT SUPPORTS FOR THE WIRES AND CABLES ONBOARD.
46 CFR 183.340
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 August 2020
Resolved
A VESSEL MUST CARRY ADEQUATE AND UP-TO-DATE DATE CHARTS OF LARGE ENOUGH SCALE TO MAKE SAFE NAVIGATION POSSIBLE, U.S. COAST PILOT AND COAST GUARD LIGHT LIST. DISCOVERED THAT THE VESSEL'S CHART AND COAST GUARD LIGHT LIST WAS OUTDATED WITH MISSING ITS U.S. COAST PILOT ONBOARD.
46 CFR 184.420 (a)
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 20 August 2020
Resolved
THE NUMBER OF PENETRATIONS IN A WATERTIGHT BULKHEAD MUST BE MINIMIZED AND SEALED WITH A VALVE OR COCK. DISCOVERED IN THE BATTERY SPACE FOUND ON THE BRIDGE WITH MULTIPLE PENETRATIONS; ONE PENETRATION WAS FOUND WITHOUT A VALVE OR COCK TO PREVENT WATER FROM ENTERING THE VESSEL.
46 CFR 179.320
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 September 2019
Resolved
Each survival craft must be: stowed so that when the vessel sinks the survival craft floats free and if inflatable, inflates automatically. Vessels life float was improperly installed with 02 hydrostatic release mechanisms. Properly install hydrostatic release on the life float.
46 CFR 180.120(a)(2)
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 September 2019
Resolved
Any vessel of at least five net tons wholly owned by a citizen or citizens of the United States is eligible for documentation under this part. Vessels Certificate of Documentation was expired. Renew vessels Certificate of Documentation and properly post on board.
46 CFR 67.5
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2019
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessels port side oil transfer pump had loose, unconnected and dead-end wires. Remove or properly connect wires associated with transfer pump.
46 CFR 182.100
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 January 2019
Resolved
The owner or managing operator shall make a vessel available for dry dock examinations as required by 46 CFR 176.600. The vessel is past due as of 01FEB2019 for a required dry dock examination. 46 CFR 176.600(c)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 June 2018
Resolved
Vessel lost power to both maine engines while underway. Require a tech report attesting to proper operations of main engines.
Construction/Loadline › Structures › Superstructure
Issued 29 May 2018
Resolved
Two bridge windows were found to be cracked. 46 CFR 177.1030
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 29 May 2018
Resolved
Two additional fire extinguishers required for dangerous material transports are not mounted.
Engineering › Bilge Water Management System › Pump
Issued 29 May 2018
Resolved
Starboard engine room and gen space bilge pumps inoperable.
Operations/Management › Vessel Activity › Other
Issued 26 July 2017
Resolved
Vessel has overdue USER FEE balance with USCG FINCEN; operator required to settle debt with FINCEN. 46 CFR 2.10-101
Engineering › Bilge Water Management System › Pump
Issued 26 July 2017
Resolved
Vessel's bilge pump in #2 void inoperable upon inspection; operator must provide proof of properly operating bilge pump in #2 void. - 46 CFR 182.500
Engineering › Bilge Water Management System › Not Operational
Issued 26 July 2017
Resolved
Vessels bilge pump indicator light in #2 void inoperable.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 March 2014
Resolved
Replace expired items in first aid kit as per 46 CFR 184.710.
Navigation › Piloting/Steering › Marine Charts
Issued 5 March 2014
Resolved
Provide current charts and U.S. Coast Pilot as per 46 CFR 184.420.
Communications › Audible Communications › Bell
Issued 5 March 2014
Resolved
Provide a bell as per 33 CFR 83.33.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 May 2012
Resolved
Provide ammonia inhalants for first aid kit.
Electrical › Electric Generation Source (service) › Panelboard
Issued 16 May 2012
Resolved
Provide and properly install "HERTZ" meter for onboard generator
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 16 May 2012
Resolved
Properly seperate child lifejackets in the starboard passenger compartment
Lifesaving › Lifejacket/PFD (Type II) › Quantity
Issued 9 December 2008
Resolved
Provide all required PFD's prior to carrying passengers.
Casualty record · 1
27 June 2018Routine · role: Involved in a Marine Casualty · activity 6494466
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.