Records from 2016 to 2025. Most recent: inspection, 22 April 2025.
Inspection history · 22
22 April 2025
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8116849
11 February 2025
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8076461
4 February 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8074787
3 July 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7947594
18 April 2023
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7670461
24 January 2023
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7624719
1 June 2022
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7464833
5 May 2021
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7188406
11 March 2021
Drydock Exam · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7153549
1 February 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7134191
20 August 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7037411
11 August 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7014598
3 September 2019
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6802465
31 January 2019
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6618278
27 June 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6457906
27 June 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6494466
29 May 2018
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6422898
22 December 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6327942
26 July 2017
Annual Inspection · Administrative Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6219569
16 February 2017
Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6089624
17 January 2017
Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6072335
25 May 2016
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5886476
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 April 2025
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Marine Inspector identified a lack of alcohol testing devices on board (alcohol test swabs), in addition to the absence of an employee list indicating personnel enrolled in the on board Drug and Alcohol Program. Provide evidence of sufficient drug and alcohol testing devices, and of a comprehensive drug and alcohol program to the satisfaction of the Marine Inspector.
46 CFR 4.06-15(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 20 May 2025
Resolution: Received satisfactory Drug & Alcohol documents.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 April 2025
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Bottom of fire extinguisher bracket near fire hose station wasted. Conduct repairs to the satisfaction of the Marine Inspector.
46 CFR 181.520
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 6 May 2025
Resolution: Received satisfactory photo from operator.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 April 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Marine Inspector identified that broken door latches on the port side vessel leading to the engine room and storage void. Conduct repairs to the satisfaction of the Marine Inspector.
46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 29 April 2025
Resolution: Received satisfactory photos of repair.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2025
Resolved
Each...ring life buoy must be marked with Type II retroreflective material...The arrangement...must be as specified by IMO Resolution A.658(16). Marine Inspector identified that the retroreflective material on the ring life buoy was weathered and peeling. Conduct repairs to the satisfaction of the Marine Inspector.
46 CFR 185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 29 April 2025
Resolution: Received satisfactory photos of repair.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 February 2025
Resolved
1) A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. The vessel has not completed a drydock examination within the last two years. Conduct satisfactory drydock examination prior to the carriage of passengers. 46 CFR 176.600(c)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2025
Resolution: Vessel completed satisfactory credit dry dock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 3 July 2024
Resolved
A hatch cover must:Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. 03 hatches found to be missing chain attached to hatch, Laz port/stbd and stbd engine room hatch.
46 CFR 179.360(b)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2024
Resolved 6 November 2024
Resolution: Deficiency corrected to the satisfaction of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2024
Resolved
Electrical equipment on a vessel must be installed and
maintained to; protect passengers, crew, other persons
,and the vessel from electrical hazards, including fire
caused by or originating in electrical equipment, and
electrical shock. Missing outlet box cover in STBD side
main seating are.
46 CFR 183.200
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2024
Resolved 6 November 2024
Resolution: Deficiency corrected to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 3 July 2024
Resolved
A vessel under 46 CFR 175.110(c) requirements must conduct a training program to address firefighting proficiency,emergency egress and must include; Training in the use and location of firefighting equipment and general firefighting knowledge and egress for each membr.
46 CFR 185.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2024
Resolved 6 November 2024
Resolution: Deficiency corrected to the satisfaction of the MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 July 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels who: Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. No records of random drug testing information was on board vessel.
46 CFR 16.230(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2024
Resolved 28 August 2024
Resolution: Operator corrected deficiency to the satisfaction of MI.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 18 April 2023
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: (1) Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Vessel is missing proof of enrollment in random drug testing procedures, personnel, and testing facilities. Provide enrollment and mandatory testing information satisfactory to Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 5 May 2023
Resolution: Received satisfactory list of crew members enrolled in DAPI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 June 2022
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Starboard bilge pump in ballast tank space is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2022
Resolved 10 June 2022
Resolution: Received video of bilge pump in operation. Sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 June 2022
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel operator could not produce certificate for servicing of pre-engineered fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2022
Resolved 21 June 2022
Resolution: Recieved certification from owner.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 1 June 2022
Resolved
Each connection to a conductor must be made with an enclosure. Oil sump pumps on both propulsion engines found to be connected with twist method (starboard) and automotive connection (port). Reconnect conductors using marine grade connections that meet UL486A and utilize a heat shrink that insulates wiring as required for hazardous locations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2022
Resolved 10 June 2022
Resolution: Oil sump pump wiring was reconnected using marine grade connections that meet UL486A and utilize a heat shrink.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 1 June 2022
Resolved
Each battery must be secured to protect against shifting with roll and pitch of the vessel. Generator start battery found unsecured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2022
Resolved 10 June 2022
Resolution: Secured generator start battery with cargo tie down.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 1 June 2022
Resolved
Connections to battery terminals with permanent type connectors. Temporary type clamps are prohibited. Generator start battery has wing nut on positive terminal.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2022
Resolved 10 June 2022
Resolution: Replaced wing nut with hex nut on generator starting battery.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 June 2022
Resolved
A vessel must comply with the applicable requirements for any radio installation as set forth in 47 CFR part 80. Vessel has VHF DSC that has not been programmed with MMSI. Program MMSI into radio.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2022
Resolved 10 June 2022
Resolution: Vessel's MMSI has been programmed into DSC VHF radio. Sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 June 2022
Resolved
A vessel must comply with the applicable requirements for any radio installations including requirements for installation certificates to be issued by the FCC as set forth in 47 CFR part 80. Vessel has expired radiotelephony certificate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2022
Resolved 10 June 2022
Resolution: Vessel has new radiotelephony safety certificate.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Marine Inspector found cardboard box placed near transformer creating a potential fire hazard. Operator removed during inspection.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 1 June 2022
Resolution: Operator removed box during inspection.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 5 May 2021
Resolved
"On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level." 46 CFR 182.530
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 13 May 2021
Resolution: Provided video evidence of audio and visual working high water level alarm.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 May 2021
Resolved
"Protect passengers, crew, other persons, and the vessel from electrical hazards." 46 CFR 183.200
Cover for electrical outlet in cabin.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 13 May 2021
Resolution: Provided photo of covering for electrical outlet.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 May 2021
Resolved
"The frame or support of each semi-portable fire extinguisher must be attached to a bulkhead or deck." 46 CFR 181.500
Install bracket onboard for extra fire extinguishers. Install before bringing extinguishers back on board.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 13 May 2021
Resolution: Removed additional fire extinguishers from the CLAM.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2021
Resolved
"Each life jacket must be marked with Type I retroreflective material." 46 CFR 185.604
Apply new tape on two life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 21 May 2021
Resolution: Provided photo evidence of new Type I reflective material on two life jackets onboard the CLAM.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 5 May 2021
Resolved
"At each initial and subsequent inspection for certification the operator shall be prepared to test the steering systems of the vessel and make available for inspection to the extent necessary to determine that they are in sutiable condition and fit for the service intended." 46 CFR 176.814
Primary steering second nut to lock in, both port and starboard side.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 13 May 2021
Resolution: Provided photo evidence of Bowma-Torq Grade 8 Head cap & Bowma-Grip prevailing torque-type locking nut.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 February 2021
Resolved
A vessel exposed to salt water more than three months in any 12 month period must undergo a drydock examination and internal structural exam at least once every two years. Operator did not make vessel available for January 2021 drydock.
46 CFR 176.600(c)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2021
Resolution: Vessel has completed inspection for credit drydock.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 August 2020
Resolved
A FIRE PUMP MUST BE ABLE TO WITHSTAND NO LESS THAN 189 LITERS (50 GALLONS) PER MINUTE AT A PRESSURE OF NOT LESS THAN 414 KPA (60 PSI) AT THE PUMP OUTLET. THE SEA VALVE WAS FOUND TO BE INEFFECTIVE RESULTING IN AN INOPERABLE FIRE PUMP.
46 CFR 181.300 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2020
Resolution: Crew provided video of sat operation of fire pump.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 20 August 2020
Resolved
A VESSEL MUST COMPLY WITH THE APPLICABLE REQUIREMENTS FOR ANY RADIO AND EPIRB INSTALLATIONS, INCLUDING THE REQUIREMENTS FOR A STATION LICENSE AND INSTALLATION CERTIFICATES TO BE ISSUED BY THE FCC, AS SET FORTH IN 47 CFR 80. DISCOVERED VESSEL'S FCC STATION & SAFETY LICENSES WERE EXPIRED.
46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 26 September 2020
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 August 2020
Resolved
EACH DISPOSABLE HYDROSTATIC RELEASE UNIT MUST BE MARKED WITH AN EXPIRATION DATE OF TWO YEARS AFTER THE DATE ON WHICH THE UNIT IS INSTALLED. DISCOVERED THAT THE DISPOSABLE HYDROSTATIC RELEASE UNIT ATTACHED TO THE VESSEL'S IBA EXPIRED.
46 CFR 185.740 (2)(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 1 October 2020
Resolution: Operator sent out picture to MI with updated disposable hydrostatic release unit.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 August 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 1 October 2020
Resolution: Operator sent a picture to MI with updated/valid battery for its life ring.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 20 August 2020
Resolved
WIRES AND CABLES SHOULD BE INSTALLED IN AN ORGANIZED MANNER WITH METAL SUPPORTS SPACED NOT MORE THAN 610 MILLIMETERS (24 INCHES) APART. DISCOVERED NUMEROUS INSUFFICIENT SUPPORTS FOR THE WIRES AND CABLES ONBOARD.
46 CFR 183.340
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 1 October 2020
Resolution: Operator sent pictures to MI exhibiting metal supports spaced not more than 24 inches in all spaces MI identified during inspection.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 August 2020
Resolved
A VESSEL MUST CARRY ADEQUATE AND UP-TO-DATE DATE CHARTS OF LARGE ENOUGH SCALE TO MAKE SAFE NAVIGATION POSSIBLE, U.S. COAST PILOT AND COAST GUARD LIGHT LIST. DISCOVERED THAT THE VESSEL'S CHART AND COAST GUARD LIGHT LIST WAS OUTDATED WITH MISSING ITS U.S. COAST PILOT ONBOARD.
46 CFR 184.420 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 1 October 2020
Resolution: Operator sent a photograph to MI exhibiting a valid/current navigiatonal chart.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 20 August 2020
Resolved
THE NUMBER OF PENETRATIONS IN A WATERTIGHT BULKHEAD MUST BE MINIMIZED AND SEALED WITH A VALVE OR COCK. DISCOVERED IN THE BATTERY SPACE FOUND ON THE BRIDGE WITH MULTIPLE PENETRATIONS; ONE PENETRATION WAS FOUND WITHOUT A VALVE OR COCK TO PREVENT WATER FROM ENTERING THE VESSEL.
46 CFR 179.320
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 1 October 2020
Resolution: Operator sent a photograph to MI exhbiting filled penetrations in bulkhead of the bridge's battery room filled with cock.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 September 2019
Resolved
Each survival craft must be: stowed so that when the vessel sinks the survival craft floats free and if inflatable, inflates automatically. Vessels life float was improperly installed with 02 hydrostatic release mechanisms. Properly install hydrostatic release on the life float.
46 CFR 180.120(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2019
Resolved 27 September 2019
Resolution: Hydrostatic Release was corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 September 2019
Resolved
Any vessel of at least five net tons wholly owned by a citizen or citizens of the United States is eligible for documentation under this part. Vessels Certificate of Documentation was expired. Renew vessels Certificate of Documentation and properly post on board.
46 CFR 67.5
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2019
Resolved 27 September 2019
Resolution: Vessel Rep renewed COD.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2019
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessels port side oil transfer pump had loose, unconnected and dead-end wires. Remove or properly connect wires associated with transfer pump.
46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2019
Resolved 27 September 2019
Resolution: Deadend wires were properly caped and secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 January 2019
Resolved
The owner or managing operator shall make a vessel available for dry dock examinations as required by 46 CFR 176.600. The vessel is past due as of 01FEB2019 for a required dry dock examination. 46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2019
Resolved 20 May 2019
Resolution: DD Completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 June 2018
Resolved
Vessel lost power to both maine engines while underway. Require a tech report attesting to proper operations of main engines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2018
Resolved 29 June 2018
Resolution: Technician serviced engines. Replaced blown fuse and battery terminal connections. Three full speed tests were conducted on maine engines. All tests were satisfactory.
Construction/Loadline › Structures › Superstructure
Issued 29 May 2018
Resolved
Two bridge windows were found to be cracked. 46 CFR 177.1030
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2018
Resolved 20 May 2019
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 29 May 2018
Resolved
Two additional fire extinguishers required for dangerous material transports are not mounted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2018
Resolved 20 May 2019
Resolution: Brackets installed.
Engineering › Bilge Water Management System › Pump
Issued 29 May 2018
Resolved
Starboard engine room and gen space bilge pumps inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2018
Resolved 18 July 2018
Operations/Management › Vessel Activity › Other
Issued 26 July 2017
Resolved
Vessel has overdue USER FEE balance with USCG FINCEN; operator required to settle debt with FINCEN. 46 CFR 2.10-101
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 17 August 2017
Resolution: Operator paid overdue FINCEN debts, and the accounts have been closed.
Engineering › Bilge Water Management System › Pump
Issued 26 July 2017
Resolved
Vessel's bilge pump in #2 void inoperable upon inspection; operator must provide proof of properly operating bilge pump in #2 void. - 46 CFR 182.500
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2017
Resolved 29 July 2017
Resolution: Bilge pump operable in #2 void.
Engineering › Bilge Water Management System › Not Operational
Issued 26 July 2017
Resolved
Vessels bilge pump indicator light in #2 void inoperable.
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 22 December 2017
Resolution: Operator provided email proof of corrected deficiency.