INDUSTRIAL URSULA is a 2007 public freight. The Coast Guard has recorded 19 inspections since 2016, most recently in August 2026, along with 7 deficiencies and 2 operational controls.
Records from 2016 to 2026. Most recent: inspection, 20 August 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it9618 - Convention (Subpart B), Gross Ton 4260 - Convention (Subpart B), Net Ton 12742 - Dead Weight, Ton 17972 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 September 2023Resolved
All electrical appartus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner.
Control panel in the steering gear room has been mnanually cut to crudely install a small fan and prvide a non-certified safe ventilation. Both cuts rsult in an undue exposure of wiring and leads PSCO to believe there is an overheating issue in the steering panel. Recitficaiton expected during drydock in Europe.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 October 2023
Resolved 26 November 2023
Resolution: Class survey sent and reviewed. Satisfactory repairs have been made.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 25 March 2022Resolved
Means of escape shall be provided so that persons on board can safely and swiftly escape to the lifeboat and liferaft embarkation deck. Safe passage to lifeboat was inhibited by wasted loading platford. 74SOLAS(04)II-2/13.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2022
Resolved 7 November 2022
Resolution: Received class report attesting to rectification of deficiency
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 25 March 2022Resolved
No change shall be made in the structural arrangements, machinery equipment and other items covered by the survey, without the sanction of teh administration. The ship was using cargo wash water tank as a temporary sewage holding tank without approval. 74SOLAS(20)11
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2022
Resolved 7 November 2022
Resolution: Received class report attesting to rectification of deficiency
Oil filtering equipment shall be of a design approved by the Administration and shall be such as will ensure that any oil mixture discharged into the sea after passing through the system has an oil content not exceeding 15 pp,. When operationally testing the oily water separator , the OWS failed to stop discharge overboard when the oil content meter detected over 15 ppm. MARPOL ANNEX I REG. 14.6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2016
Resolution: Vessel submitted class report attesting to repair.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 21 October 2016Resolved
0799-The fixed fire detection shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature, or other phenomena associated with the incipient fires to which the detector is designed to respond. Flame detectors were tested with a flame torch that had an open flame approximately 12 inches. 74 SOLAS '04 II-2/7.3.2.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2016
Resolution: Vessel submitted class report attesting to repair.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 21 October 2016Resolved
0628-Each liferaft or group of liferafts shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the Code so that each floats free and, if inflatable, inflates automatically when the ship sinks. Hydrostatic release unit for the starboard liferaft was installed inverted. 74 SOLAS '14 iii/13.4.2.
Action required: 705 - Other - as specified
Resolved 26 October 2016
Tubrocharger for the main propulsion engine failed, causing a loss of propulsion.
Action required: 705 - Other - as specified
Resolved 3 November 2016
Resolution: Vessel submitted class report attesting to repair and proper operation of equipment.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.