MAURY USCG vessel records
← All vessels

EVRIDIKI

EVRIDIKI is a 2008 tank ship. The Coast Guard has recorded 9 inspections since 2017, most recently in March 2026, along with 6 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 30 March 2026.

Built
2008
Last inspected
30 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 March 2026
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9358929
992268
Flag
BAHAMAS, THE
Maury page id
psix-992268

Documentation record

Tonnage as PSIX records it42048 - Convention (Subpart B), Gross Ton
22309 - Convention (Subpart B), Net Ton
73740 - Dead Weight, Metric Ton
89381 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

30 March 2026 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8334546
15 March 2026 PSC B · COC-TVE Renew
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8319331
9 March 2026 COE-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8334096
10 June 2024 PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7926762
15 February 2022 PSC B · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7396424
22 December 2019 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6874357
5 September 2018 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6533296
13 March 2017 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6104066
9 February 2017 Deficiency Check · Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6085696

Deficiency record · 6

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2026 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed more than 5 electrical breakers installed at an amperage higher than the designed amperage raring in the ECR and EDG spaces. 74SOLAS(04) II-1/40/1.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2026
Resolved 30 March 2026
Resolution: PSCO received Class (BV) report attesting to the rectification of deficiency.
Deck/Cargo › Inert Gas System › Scrubber Tower
Issued 20 February 2017 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. IGS is leaking IG into space and soft patches on the scrubber body. SOLAS74(2014 CONS.) I/11(a) 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2017
Resolution: Received scanned copy of BV class report attesting to the repair. See "documents" for class report.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 15 February 2017 Resolved
Cargo pump #1 and #2 have leaking mechanical seals and fittings allowing cargo to enter pump room. 74SOLAS(2014 CONS ED.) 1/11(a) - 60ac
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2017
Resolution: Agent has provided a copy of class report from BV attesting to the rectification of the deficiency. See class report in "documents".
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 15 February 2017 Resolved
Inert gas system is leaking IG into space and there are several pin hole leaks and soft patches on the scrubber. 74SOLAS(2014 CONS ED.) 1/11(a) - 60ac
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2017
Resolution: Agent has provided a copy of class report from BV attesting to the rectification of the deficiency. See class report in "documents".
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 15 February 2017 Resolved
Three of the vessel's VCS pins were not permanently affixed. 46CFR39.2001(j) - 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 March 2017
Resolution: Received Class Survey attesting to the repairs of the IG system piping.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 15 February 2017 Resolved
MSD has pinhole leaks and several soft patches on the body and piping. 74Solas(2014Cons)1/11a - 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 March 2017
Resolution: Received satisfactory Class Survey.

Ownership record