ATLANTIS ALEXANDRIA is a 2008 tank ship. The Coast Guard has recorded 15 inspections since 2016, most recently in May 2026, along with 2 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 3 May 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it29305 - Convention (Subpart B), Gross Ton 13134 - Convention (Subpart B), Net Ton 59151 - Displacement, Metric Ton 49999 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 September 2024Resolved
Doors and door frames in "A" class divisions, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkhead in which the doors are situated. "A" boundary self-closing door from stairway into bridge does not meet full "A" boundary requirement, door has pass-through holes and missing parts.
74 SOLAS (20) II-2/9.4.1.1.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2024
Resolved 24 September 2024
Resolution: Received sat class report.
Construction/Loadline › Structures › Deck Plating
Issued 8 June 2017Resolved
Deck plating on the safe access to the bow was found with clamps that were unsecured, wasted, or missing causing many to shift under foot and which causes an unnecessary trip hazard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 June 2017
Resolution: Received Class documentation attesting to adequate repairs and renewal of the wasted securing clamps for the safe access to the bow.