Records from 2009 to 2026. Most recent: inspection, 6 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 33
6 March 2026
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8314980
13 January 2026
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8295467
6 March 2025
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8089180
27 February 2024
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7868010
25 January 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7855662
2 March 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7643729
9 August 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7528021
9 March 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7403243
3 February 2022
Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7390446
15 September 2021
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7302546
12 May 2021
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7194964
26 March 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7199910
8 March 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7150260
17 October 2020
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7084542
21 September 2020
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7062175
15 May 2020
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6961721
20 March 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6929464
22 January 2020
Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6893700
29 May 2019
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6703877
17 May 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6688952
6 May 2019
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6678488
5 May 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6681361
18 March 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6645010
25 February 2019
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6631647
12 July 2018
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6476894
25 April 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6387793
23 January 2018
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6341911
23 October 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6293825
7 April 2017
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6119863
6 April 2017
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6124000
13 March 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6100870
25 April 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5861840
5 January 2016
Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5791510
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2024
Resolved
Each ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Retro-reflective tape was found wasted. Renew in kind
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: Ring buoy had new SOLAS tape and repaired IAW 835.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2024
Resolved
Each lifeline on a ring life buoy must: Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Current lifeline for the life ring buoy is not dark color.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: New line was installed IAW 835.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2024
Resolved
Each floating water-light must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Water-light is cracked and found un-serviceable. Renew and prove proper operation.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2024
Resolved 7 March 2024
Resolution: Waterlight is operational. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 February 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Anchor light
not properly operating.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: Witnessed anchor light operational.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 February 2024
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter and Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter. Only four distress signals were onboard the vessel. Provide additional distress signals.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: Vessel had correct type and amount of flares IAW 835.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 February 2024
Resolved
t each initial and subsequent inspection for certification, the owner or managing operator must have the vessel ready for inspection of its fire protection equipment, including the following: (1) Inspection of each portable fire extinguisher to check for excessive corrosion and general condition. Found excessive corrosion on upper pilothouse portable extinguisher. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: Vessel had new fire ext. installed at new approved location inside the pilot house.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 February 2024
Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter fire-hose is required by § 181.320(b). Prove 02 spanner wrenches for fire station.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2024
Resolved 7 March 2024
Resolution: Vessel has required spanner wrenches.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 February 2024
Resolved
Each vessel must be equipped with at least two operable
portable battery lights. No portable lights provided during the inspection.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: Vessel has 02 operational flash lights.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 27 February 2024
Resolved
Watertight hatches must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: or “WATERTIGHT HATCH—KEEP CLOSED”, unless such markings are deemed unnecessary by the cognizant [name withheld] on board were not properly marked.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2024
Resolved 7 March 2024
Resolution: Crew painted all deck hatches IAW 835.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 February 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Renew expired items.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2024
Resolved 7 March 2024
Resolution: Vessel has up to date first aid kit IAW 835.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 27 February 2024
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part. Emergency drills were not conducted every three months and logged. Conduct fire and man overboard drill during the COI inspection prior to carrying passengers.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 27 February 2024
Resolution: Witnessed MOB and fire drill. Master properly logged emergency drills to include: Location, people present, lessons learned, and description.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 January 2024
Resolved
A vessel is inspected for compliance with the standards required by this sub-chapter. Make proper repair to fractured welds as marked in Port and STBD lazzerette spaces.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 February 2024
Resolution: Welds were gouged and re-welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 January 2024
Resolved
A vessel is inspected for compliance with the standards required by this sub-chapter. Make repairs on pipe for stbd raw water shaft flushing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 February 2024
Resolution: New pipe was installed and properly working as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2023
Resolved
Life preservers shall be of first-class workmanship and shall be free from any defects materially affecting their appearance or service-ability. Found 02 Adult sized life jackets wasted. Vessel restricted to 49 total persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 March 2023
Resolution: 02 Life jackets renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 March 2023
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Portside fwd void suction foot was found corroded. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2023
Resolved 13 March 2023
Resolution: Suction strainer renewed in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 2 March 2023
Resolved
§ 182.445 Fill and sounding pipes for fuel tanks:When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. Bonding wire missing on both fuel tanks fill flexible section.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2023
Resolved 13 March 2023
Resolution: Conductors installed between flexible fuel fill hose on both tanks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 March 2023
Resolved
There must be a means of accurately determining the
amount of fuel in each fuel tank either by sounding,
through a separate sounding pipe or a fill pipe, or by
an installed marine type fuel gauge. No means provided.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2023
Resolved 13 March 2023
Resolution: Manual gauge sticks properly marked and stored onboard the vessel for use.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 2 March 2023
Resolved
§ 185.510 Emergency instructions: The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Post emergency instructions at the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2023
Resolved 13 March 2023
Resolution: Emergency instructions posted on the bridge console made available to the Master.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 March 2022
Resolved
Piping used in vital systems must: Be composed of ferrous materials except when nonmetallic piping materials are permitted by 182.720 or nonferrous metallic piping materials permitted by 182.730. Fire pump discharge hose burst during operational test. MI noted flexible hose is not rated or installed IAW 46 CFR 182.720(c).
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2022
Resolution: Flexible hose meeting CFR 182.720(c) was installed on the fire pump discharge and tested to the satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 March 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or marine operator to have the vessel ready for inspection of lifesaving equipment. Life ring water light is damaged and and wrong batteries installed. Renew water light.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2022
Resolved 23 March 2022
Resolution: Waterlight renewed and properly installed in the bracket.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 March 2022
Resolved
Maintain drug and alcohol program IAW 46 CFR 16.401. Hotline numbers not posted in common space and master could not prove supervisory and general crew member awareness training.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2022
Resolved 23 March 2022
Resolution: Hotline numbers properly posted in common space and crewmember awareness training conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements. MI noted high jacket water on starboard main engine while underway. Make effective repairs and prove proper operation.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2022
Resolution: J/W pump was renewed. Satisfactory sea trials were conducted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 September 2021
Resolved
Before getting underway or as soon as practicable there after the master of a vessel shall ensure that a suitable public announcements are made informing all passengers. During follow up inspection M/I noted no passenger orientation was being conducted.
Discussed, observed crew complete prior to getting underway to the satisfaction of the attending inspector.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 15 September 2021
Resolved 15 September 2021
Resolution: Completed to the satisfaction of the attending inspector.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 March 2021
Resolved
FCC Radiotelephony safety cert expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 March 2021
Resolution: FCC cert provided by FCC
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 March 2021
Resolved
fire drills are not properly logged.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2021
Resolution: Logged fire drill following inspection.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 March 2021
Resolved
Provide up to date Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2021
Resolution: Provided up to date pubs
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 March 2021
Resolved
Provide up to date light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2021
Resolution: Provided up to date pubs.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 March 2021
Resolved
Renew grab line for life ring buoy.
Action required: 705 - Other - as specified
Due 15 March 2021
Resolved 10 March 2021
Resolution: New lines installed
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 March 2021
Resolved
Renew life ring buoy waterlight line.
Action required: 705 - Other - as specified
Due 15 March 2021
Resolved 10 March 2021
Resolution: Renewed lines
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 March 2021
Resolved
Port main deck fire extinguisher horn is broken.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2021
Resolution: New ext. installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2021
Resolved
Install lock nut/ cotter pin for port and stbd tiller arm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2021
Resolution: New lock nuts installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2021
Resolved
Port FWD peak light is loose. properly secure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2021
Resolution: Light properly mounted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 March 2021
Resolved
Renew stbd rudder indicator with boat cable. MI found wired with drop cord.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 March 2021
Resolution: Boat cable installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2021
Resolved
Replace adult lifejack
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2021
Resolution: Life jacket installed and marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2021
Resolved
Conduct sufficient fire drills to make sure that crew is familiar with his or her duties.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2021
Resolution: Held training
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 October 2020
Resolved
Crew must be identified in log book for each run to ensure no CAPT or Crew is running more than 12 hrs.
Action required: 705 - Other - as specified
Due 18 October 2020
Resolved 18 October 2020
Resolution: Owner provided log entry as discussed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 March 2020
Resolved
Fire boy shut downs not securing port or STBD engines when tested. Vessel will be conducting 15 min rounds and logging once completed until shut downs are fixed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2020
Resolved 25 March 2020
Resolution: Operator error was the cause of the system not properly operating.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 March 2020
Resolved
When testing fire pump gauge read 160 PSI and blew the discharge hose off of the pump due to improper hose fitting. Fitting wasnt barbed. Three addition fitting were ID'd for replacement.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2020
Resolution: New fittings installed and system tested.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 March 2020
Resolved
VHF radio for shore side not operational. The vessel doesnt have life floats as per requlation becuase they have comms with a shore base facility. Fix shore side VFH or install life floats. Vessel was operating like this since hurricane season when the VHF radio shore side was damaged.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2020
Resolution: A temp VHF has been installed and tested.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 March 2020
Resolved
VHF Radio MIC missing transmit button. This is one of two VHFs on the bridge. Other radio test SAT.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 April 2020
Resolution: New mic installed
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 March 2020
Resolved
Ring buoy life lines wasted. Replace all lines to float light , grab lines, and throw line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 April 2020
Resolution: New life ring and lines installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 March 2020
Resolved
Remove gear from Childs lifejacket storage box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2020
Resolution: All gear removed and owner is going to build a new divider.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2020
Resolved
Hydrulic hose needs new fittings due to improper connections on the suction side.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 April 2020
Resolution: Port and Stbd Hydrulic fitting replaced with proper SAE fiiting and are no longer slip on. Photos provided by o/o as objective evidence during the COVID 19 period.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 20 March 2020
Resolved
No logged MOB and Fire drills. Master stated they normally do drills when we are on board. Conduct drills and log monthly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2020
Resolution: Drills conducted and logged by crew. MOB and Fire Drill.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 January 2020
Resolved
Reconfigure sea water intake for hydralic oil cooling.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 January 2020
Resolved 20 March 2020
Resolution: New suction pipe installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2019
Resolved
Exhaust flex joint removed and unapproved exhaust pipe installed. Install exhaust as per approved plans.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2019
Resolved 28 June 2019
Resolution: Exhaust for port and STBD MDE installed back to original.
Documentation › Certificates/Documents › Permit, Other
Issued 25 April 2018
Resolved
Radio Operators Permit not issued to CAPT
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 12 July 2018
Resolution: Radio operators permmit obtained
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 25 April 2018
Resolved
Three fuel lines leaking off governor
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2018
Resolved 25 April 2018
Resolution: Tightened and tested. Vessel crew to check for leaks while doing engine room rounds.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 April 2018
Resolved
Testing strips out of date
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 12 July 2018
Resolution: New test strips provided from drug and alcohol consortium
Communications › Audible Communications › Horn/Whistle
Issued 25 April 2018
Resolved
Horn not sounding, hand held provided as temp.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 12 July 2018
Resolution: Clean out horn air inlet.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2018
Resolved
First aid kit expired meds and missing meds. Provide approved 160.041 kit
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 12 July 2018
Resolution: New first aid kit placed on vessel.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 25 April 2018
Resolved
All flares expire in Jun 2018
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 25 April 2018
Resolution: Installed new red rocket flares 6 needed installed 8
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 25 April 2018
Resolved
MOB Lifejacket harness improperly connnected to MOB platform. Harness cant be connected to MOB Platform. Attach to vsl and demonstrate for CG.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 12 July 2018
Resolution: New line install same day as inspection.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 April 2018
Resolved
False bilge alarms while underway. Port crash and STBD fwd alarms would not clear.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2018
Resolved 25 April 2018
Resolution: exercised bilge alarms.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Waste Heat Recovery
Issued 7 April 2017
Resolved
UNKNOWN issue until, MDE overheat is the report and owner wants to replace with in kind engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2017
Resolution: Replaced port engine with new. Unknown issue with old port engine dropping RPMs
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 March 2017
Resolved
51 Lifejackets failed inspection due to break down of foam material.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2017
Construction/Loadline › Hull › Bottom Plating
Issued 13 March 2017
Resolved
Make repairs to fractures welds were indicatted in fwd compartment frames 3&4 (portside) and frames 4 in fwd compartment stbd side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 16 March 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 March 2017
Resolved
first aid kit expired
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2017
Resolved 16 March 2017