MISS BRENDA

MISS BRENDA is a 2008 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 2016, most recently in March 2026, along with 58 deficiencies and 14 casualty investigations between 2009 and 2021.

Records from 2009 to 2026. Most recent: inspection, 6 March 2026.

Built
2008
Last inspected
6 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 March 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE7312
992479
Flag
UNITED STATES
Maury page id
psix-992479

Documentation record

Registered dimensions (L × B × D)48.0 ft × 22.5 ft × 6.0 ft
Registered tonnagegross 54 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCUSTOM STEEL BOATS INC · MERRITT, NC, UNITED STATES · built 2008
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portDAVIS SHORE, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Simplified, Gross Ton
43 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

33 inspections, each with its date, unit and type; 58 deficiencies with the resolution recorded against each; 14 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 33

6 March 2026 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8314980
13 January 2026 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8295467
6 March 2025 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8089180
27 February 2024 COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7868010
25 January 2024 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7855662
2 March 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7643729
9 August 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7528021
9 March 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7403243
3 February 2022 Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7390446
15 September 2021 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7302546
12 May 2021 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7194964
26 March 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7199910
8 March 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7150260
17 October 2020 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7084542
21 September 2020 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7062175
15 May 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6961721
20 March 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6929464
22 January 2020 Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6893700
29 May 2019 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6703877
17 May 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6688952
6 May 2019 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6678488
5 May 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6681361
18 March 2019 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6645010
25 February 2019 COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6631647
12 July 2018 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6476894
25 April 2018 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6387793
23 January 2018 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6341911
23 October 2017 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6293825
7 April 2017 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6119863
6 April 2017 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6124000
13 March 2017 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6100870
25 April 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5861840
5 January 2016 Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5791510

Deficiency record · 58

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2024 Resolved
Each ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Retro-reflective tape was found wasted. Renew in kind
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: Ring buoy had new SOLAS tape and repaired IAW 835.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2024 Resolved
Each lifeline on a ring life buoy must: Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Current lifeline for the life ring buoy is not dark color.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: New line was installed IAW 835.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2024 Resolved
Each floating water-light must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Water-light is cracked and found un-serviceable. Renew and prove proper operation.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2024
Resolved 7 March 2024
Resolution: Waterlight is operational. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 February 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Anchor light not properly operating.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: Witnessed anchor light operational.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 February 2024 Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter and Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter. Only four distress signals were onboard the vessel. Provide additional distress signals.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: Vessel had correct type and amount of flares IAW 835.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 February 2024 Resolved
t each initial and subsequent inspection for certification, the owner or managing operator must have the vessel ready for inspection of its fire protection equipment, including the following: (1) Inspection of each portable fire extinguisher to check for excessive corrosion and general condition. Found excessive corrosion on upper pilothouse portable extinguisher. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: Vessel had new fire ext. installed at new approved location inside the pilot house.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 February 2024 Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter fire-hose is required by § 181.320(b). Prove 02 spanner wrenches for fire station.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2024
Resolved 7 March 2024
Resolution: Vessel has required spanner wrenches.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 February 2024 Resolved
Each vessel must be equipped with at least two operable portable battery lights. No portable lights provided during the inspection.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 7 March 2024
Resolution: Vessel has 02 operational flash lights.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 27 February 2024 Resolved
Watertight hatches must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: or “WATERTIGHT HATCH—KEEP CLOSED”, unless such markings are deemed unnecessary by the cognizant [name withheld] on board were not properly marked.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2024
Resolved 7 March 2024
Resolution: Crew painted all deck hatches IAW 835.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 February 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Renew expired items.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2024
Resolved 7 March 2024
Resolution: Vessel has up to date first aid kit IAW 835.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 27 February 2024 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part. Emergency drills were not conducted every three months and logged. Conduct fire and man overboard drill during the COI inspection prior to carrying passengers.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 27 February 2024
Resolution: Witnessed MOB and fire drill. Master properly logged emergency drills to include: Location, people present, lessons learned, and description.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 January 2024 Resolved
A vessel is inspected for compliance with the standards required by this sub-chapter. Make proper repair to fractured welds as marked in Port and STBD lazzerette spaces.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 February 2024
Resolution: Welds were gouged and re-welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 January 2024 Resolved
A vessel is inspected for compliance with the standards required by this sub-chapter. Make repairs on pipe for stbd raw water shaft flushing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 February 2024
Resolution: New pipe was installed and properly working as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2023 Resolved
Life preservers shall be of first-class workmanship and shall be free from any defects materially affecting their appearance or service-ability. Found 02 Adult sized life jackets wasted. Vessel restricted to 49 total persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 March 2023
Resolution: 02 Life jackets renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 March 2023 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Portside fwd void suction foot was found corroded. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2023
Resolved 13 March 2023
Resolution: Suction strainer renewed in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 2 March 2023 Resolved
§ 182.445 Fill and sounding pipes for fuel tanks:When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. Bonding wire missing on both fuel tanks fill flexible section.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2023
Resolved 13 March 2023
Resolution: Conductors installed between flexible fuel fill hose on both tanks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 March 2023 Resolved
There must be a means of accurately determining the amount of fuel in each fuel tank either by sounding, through a separate sounding pipe or a fill pipe, or by an installed marine type fuel gauge. No means provided.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2023
Resolved 13 March 2023
Resolution: Manual gauge sticks properly marked and stored onboard the vessel for use.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 2 March 2023 Resolved
§ 185.510 Emergency instructions: The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Post emergency instructions at the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2023
Resolved 13 March 2023
Resolution: Emergency instructions posted on the bridge console made available to the Master.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 March 2022 Resolved
Piping used in vital systems must: Be composed of ferrous materials except when nonmetallic piping materials are permitted by 182.720 or nonferrous metallic piping materials permitted by 182.730. Fire pump discharge hose burst during operational test. MI noted flexible hose is not rated or installed IAW 46 CFR 182.720(c).
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2022
Resolution: Flexible hose meeting CFR 182.720(c) was installed on the fire pump discharge and tested to the satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 March 2022 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or marine operator to have the vessel ready for inspection of lifesaving equipment. Life ring water light is damaged and and wrong batteries installed. Renew water light.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2022
Resolved 23 March 2022
Resolution: Waterlight renewed and properly installed in the bracket.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 March 2022 Resolved
Maintain drug and alcohol program IAW 46 CFR 16.401. Hotline numbers not posted in common space and master could not prove supervisory and general crew member awareness training.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2022
Resolved 23 March 2022
Resolution: Hotline numbers properly posted in common space and crewmember awareness training conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements. MI noted high jacket water on starboard main engine while underway. Make effective repairs and prove proper operation.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2022
Resolution: J/W pump was renewed. Satisfactory sea trials were conducted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 September 2021 Resolved
Before getting underway or as soon as practicable there after the master of a vessel shall ensure that a suitable public announcements are made informing all passengers. During follow up inspection M/I noted no passenger orientation was being conducted. Discussed, observed crew complete prior to getting underway to the satisfaction of the attending inspector.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 15 September 2021
Resolved 15 September 2021
Resolution: Completed to the satisfaction of the attending inspector.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 March 2021 Resolved
FCC Radiotelephony safety cert expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 March 2021
Resolution: FCC cert provided by FCC
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 March 2021 Resolved
fire drills are not properly logged.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2021
Resolution: Logged fire drill following inspection.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 March 2021 Resolved
Provide up to date Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2021
Resolution: Provided up to date pubs
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 March 2021 Resolved
Provide up to date light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2021
Resolution: Provided up to date pubs.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 March 2021 Resolved
Renew grab line for life ring buoy.
Action required: 705 - Other - as specified
Due 15 March 2021
Resolved 10 March 2021
Resolution: New lines installed
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 March 2021 Resolved
Renew life ring buoy waterlight line.
Action required: 705 - Other - as specified
Due 15 March 2021
Resolved 10 March 2021
Resolution: Renewed lines
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 March 2021 Resolved
Port main deck fire extinguisher horn is broken.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2021
Resolution: New ext. installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2021 Resolved
Install lock nut/ cotter pin for port and stbd tiller arm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2021
Resolution: New lock nuts installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2021 Resolved
Port FWD peak light is loose. properly secure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2021
Resolution: Light properly mounted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 March 2021 Resolved
Renew stbd rudder indicator with boat cable. MI found wired with drop cord.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 March 2021
Resolution: Boat cable installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2021 Resolved
Replace adult lifejack
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2021
Resolution: Life jacket installed and marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2021 Resolved
Conduct sufficient fire drills to make sure that crew is familiar with his or her duties.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2021
Resolution: Held training
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 October 2020 Resolved
Crew must be identified in log book for each run to ensure no CAPT or Crew is running more than 12 hrs.
Action required: 705 - Other - as specified
Due 18 October 2020
Resolved 18 October 2020
Resolution: Owner provided log entry as discussed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 March 2020 Resolved
Fire boy shut downs not securing port or STBD engines when tested. Vessel will be conducting 15 min rounds and logging once completed until shut downs are fixed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2020
Resolved 25 March 2020
Resolution: Operator error was the cause of the system not properly operating.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 March 2020 Resolved
When testing fire pump gauge read 160 PSI and blew the discharge hose off of the pump due to improper hose fitting. Fitting wasnt barbed. Three addition fitting were ID'd for replacement.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2020
Resolution: New fittings installed and system tested.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 March 2020 Resolved
VHF radio for shore side not operational. The vessel doesnt have life floats as per requlation becuase they have comms with a shore base facility. Fix shore side VFH or install life floats. Vessel was operating like this since hurricane season when the VHF radio shore side was damaged.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2020
Resolution: A temp VHF has been installed and tested.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 March 2020 Resolved
VHF Radio MIC missing transmit button. This is one of two VHFs on the bridge. Other radio test SAT.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 April 2020
Resolution: New mic installed
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 March 2020 Resolved
Ring buoy life lines wasted. Replace all lines to float light , grab lines, and throw line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 April 2020
Resolution: New life ring and lines installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 March 2020 Resolved
Remove gear from Childs lifejacket storage box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2020
Resolution: All gear removed and owner is going to build a new divider.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2020 Resolved
Hydrulic hose needs new fittings due to improper connections on the suction side.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 April 2020
Resolution: Port and Stbd Hydrulic fitting replaced with proper SAE fiiting and are no longer slip on. Photos provided by o/o as objective evidence during the COVID 19 period.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 20 March 2020 Resolved
No logged MOB and Fire drills. Master stated they normally do drills when we are on board. Conduct drills and log monthly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2020
Resolution: Drills conducted and logged by crew. MOB and Fire Drill.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 January 2020 Resolved
Reconfigure sea water intake for hydralic oil cooling.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 January 2020
Resolved 20 March 2020
Resolution: New suction pipe installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2019 Resolved
Exhaust flex joint removed and unapproved exhaust pipe installed. Install exhaust as per approved plans.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2019
Resolved 28 June 2019
Resolution: Exhaust for port and STBD MDE installed back to original.
Documentation › Certificates/Documents › Permit, Other
Issued 25 April 2018 Resolved
Radio Operators Permit not issued to CAPT
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 12 July 2018
Resolution: Radio operators permmit obtained
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 25 April 2018 Resolved
Three fuel lines leaking off governor
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2018
Resolved 25 April 2018
Resolution: Tightened and tested. Vessel crew to check for leaks while doing engine room rounds.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 April 2018 Resolved
Testing strips out of date
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 12 July 2018
Resolution: New test strips provided from drug and alcohol consortium
Communications › Audible Communications › Horn/Whistle
Issued 25 April 2018 Resolved
Horn not sounding, hand held provided as temp.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 12 July 2018
Resolution: Clean out horn air inlet.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2018 Resolved
First aid kit expired meds and missing meds. Provide approved 160.041 kit
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 12 July 2018
Resolution: New first aid kit placed on vessel.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 25 April 2018 Resolved
All flares expire in Jun 2018
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 25 April 2018
Resolution: Installed new red rocket flares 6 needed installed 8
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 25 April 2018 Resolved
MOB Lifejacket harness improperly connnected to MOB platform. Harness cant be connected to MOB Platform. Attach to vsl and demonstrate for CG.
Action required: 705 - Other - as specified
Due 25 May 2018
Resolved 12 July 2018
Resolution: New line install same day as inspection.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 April 2018 Resolved
False bilge alarms while underway. Port crash and STBD fwd alarms would not clear.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2018
Resolved 25 April 2018
Resolution: exercised bilge alarms.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Waste Heat Recovery
Issued 7 April 2017 Resolved
UNKNOWN issue until, MDE overheat is the report and owner wants to replace with in kind engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2017
Resolution: Replaced port engine with new. Unknown issue with old port engine dropping RPMs
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 March 2017 Resolved
51 Lifejackets failed inspection due to break down of foam material.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2017
Construction/Loadline › Hull › Bottom Plating
Issued 13 March 2017 Resolved
Make repairs to fractures welds were indicatted in fwd compartment frames 3&4 (portside) and frames 4 in fwd compartment stbd side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 16 March 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 March 2017 Resolved
first aid kit expired
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2017
Resolved 16 March 2017

Casualty record · 14

2 February 2009Routine · role: Involved in a Marine Casualty · activity 3416041
22 March 2009Routine · role: Involved in a Marine Casualty · activity 3438802
31 March 2009Routine · role: Involved in a Marine Casualty · activity 3444148
3 April 2009Routine · role: Involved in a Marine Casualty · activity 3448584
19 May 2009Routine · role: Involved in a Marine Casualty · activity 3481135
23 May 2009Routine · role: Involved in a Marine Casualty · activity 3493161
7 April 2010Routine · role: Involved in a Marine Casualty · activity 3714832
1 May 2010Routine · role: Involved in a Marine Casualty · activity 3729645
2 July 2015Routine · role: Involved in a Marine Casualty · activity 5923975
6 April 2017Routine · role: Involved in a Marine Casualty · activity 6124000
5 May 2019Routine · role: Involved in a Marine Casualty · activity 6681361
17 May 2019Routine · role: Involved in a Marine Casualty · activity 6688952
15 May 2020Routine · role: Involved in a Marine Casualty · activity 6961721
26 March 2021Routine · role: Involved in a Marine Casualty · activity 7199910
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.