MAURY USCG vessel records Sign in
← All vessels

ENSCO 8500

ENSCO 8500 is a mobile offshore drilling unit. The Coast Guard has recorded 8 inspections since 2009, most recently in October 2014, along with 3 deficiencies.

Records from 2009 to 2014. Most recent: inspection, 27 October 2014.

Built
Not recorded
Last inspected
27 October 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8768787 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
992604
Flag
LIBERIA
—
Maury page id
psix-992604

Inspections, by type

…with no type recorded1
Years with a record 5 calendar years (2009–2014)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it5813 - Simplified, Net Ton
19377 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

27 October 2014 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5012889
9 May 2014 COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4854086
6 July 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4369987
30 August 2011 Deficiency Check · NPV Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4131481
26 August 2011 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4127738
1 February 2011 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3933830
7 September 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3886528
28 January 2009 In-Service Inspection · COC-MODU Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3401755

Deficiency record · 3

Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 20 May 2014 Resolved
Stairways which penetrate more than a single deck should be surrounded by "A" class divsion. Fie Doors installed do not match manufacture approval series for "A" class doors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2014
Resolved 7 January 2015
Resolution: ABS, attended and verified that all stairwell self closing fire doors have been replaced with new A-60 Fire doors that are fitted with a proper latching mechanism. All supporting and relevant documentation reviewed to the satisfation of the ABS inspector
Engineering › Electric Propulsion System › Auto Transformer Circuitry
Issued 30 August 2011 Resolved
Prior to conducting drilling operations correct correct the single point failure in the Power Management System that prevents the overcurrent/overfrequency from isolating affected generator prior to tripping the reverse power relay on un-affected generators (to meet DP-2) Make necessary corrections to FEMA, operations and maintenance publications.
Action required: 705 - Other - as specified
Resolved 12 October 2011
Resolution: Electrical engineering proposed modification to PMS reviewed and approved by ABS engineering and CG inspector. ABE surveyor attended vessel and witnessed satisfactory testing. Deficiency Cleared.
Engineering › Bilge Water Management System › Valve
Issued 7 February 2011 Resolved
Prove proper operation of al manual operated bilge valves in each column.
Due 21 February 2011
Resolved 14 February 2011

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.