04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 6 November 2024
Resolved
On a vessel of at least 26ft in length, a visual and
audible alarm must be provided at the operating
station to indicate a high water level in normally
unmanned spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2024
Resolved 6 November 2024
Resolution: fixed audible high water alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 November 2024
Resolved
The name of a vessel must be marked or painted in
clearly legible letters and numbers. Ring buoy needs
to be marked with vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2024
Resolved 6 November 2024
Resolution: Life bouy has been marked with vessel name.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 November 2022
Resolved
FCC Safety Certificate expired Sept 2022. Must renew FCC Safety Certificate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2022
Resolved 1 December 2022
Resolution: New FCC Safety Certificate was issued
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 January 2022
Resolved
Stern NAV light was found not working. Must make repairs & test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2022
Resolution: Installed new bulb and tighten all connections.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 11 January 2022
Resolved
Aft life float is faded and almost black on the entire top. Must clean/repaint life float.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 4 February 2022
Resolution: Repainted life float
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 January 2022
Resolved
Life ring buoy was faded and grab line was dry rotted. Must repaint life ring and replace grab line or replace life ring entirely.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 24 January 2022
Resolution: Brand new life ring onboard vessel
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 January 2022
Resolved
First aid kit was found missing several items. Must replace all missing items to meet requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 4 February 2022
Resolution: New first aid kit that meets 46 CFR 160.041
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 11 January 2022
Resolved
Due to weather, un able to get vessel underway to conduct MOB and Fire drills. Must conduct drills in the next 30 days.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 24 January 2022
Resolution: Conducted MOB and fire drills, SAT
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 January 2022
Resolved
Fire pump is showing 45-50 psi at discharge side of pump on guage. Requirement is 60 psi. Hose seams to have good psi with approx 40 foot stream at the nozzle. Make repairs to system to achieve the 60 psi requirement.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 24 January 2022
Resolution: Replaced gauge and tighten bolts on sea strainer lid
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 December 2021
Resolved
Vessel was caught operating with passengers when not cleared from drydock repairs. Both port and starboard hatches were found laying on deck and not sealed and bolted to deck making them non watertight hatches. Must seal and bolt down hatches to make watertight prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 December 2021
Resolution: Both hatche rings were sealed and bolted to deck.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 December 2021
Resolved
Vessel was found operating with passengers when not cleared from drydock repairs. Port MDE raw water through hull valve was found not repaired. Valve only closes around 60 percent. Make repairs to valve to where it closes 100 percent prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 December 2021
Resolution: Bent the valve handle so it would clear the frame. Test SAT.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 November 2021
Resolved
Dig out all rot on deck core around both port and STBD fwd cabin hatches for further inspection.
Vessel plans on re decking the vessel next month. Vessel will make permmanent repairs then.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2021
Resolved 28 January 2022
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 16 September 2021
Resolved
EPIRB failed testing sequence. Found the battery expired on May, 2021. Vessel restircted to 3 miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2021
Resolved 1 October 2021
Resolution: Bought new EPRIB, registered and tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 September 2021
Resolved
03 lifefloats found with missing or faded lettering of vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2021
Resolved 23 September 2021
Resolution: 03 lifefloats inspected, found with vessel's name and passenger capacities re-stenciled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 September 2021
Resolved
Lifering found with missing or faded lettering of vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2021
Resolved 23 September 2021
Resolution: Lifering inspected, found with vessel's name re-stenciled.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 September 2021
Resolved
02 floatlights found extinguished.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2021
Resolved 23 September 2021
Resolution: Inspected all floatlights, 03 new floatlights found functional and properly attached to lifefloats.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 21 January 2021
Resolved
STBD side bilge visual indicators not working. Must conduct repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengiers.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 21 January 2021
Resolved 21 January 2021
Resolution: Replaced both lights with new lights. Tested SAT
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 21 January 2021
Resolved
STBD side aft high water alarm not working. Make repairs and test to the satisfaction on attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 21 January 2021
Resolved 21 January 2021
Resolution: Replaced alarm with new alarm. Tested SAT
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 January 2021
Resolved
Fire pump would only reach 40 PSI instead of the 60 PSI required. Conduct repairs and test to the satisfaction of the attending CG Marine Inspector prior to carrying passengers
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 21 January 2021
Resolved 21 January 2021
Resolution: Crew did not know they had to raise the RPM's on the STBD engine to make the water pressure increase on the fire pump. Raised RPM's and reached 65 psi. Test SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 January 2021
Resolved
Vessel is missing 1 of the 4 required fire extinguishers. Must add 1 new CG approved fire extinguisher priort to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 21 January 2021
Resolved 21 January 2021
Resolution: Bought new fire extinguisher, all SAT
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 January 2021
Resolved
Stern light was not working and missing the lens. Make repairs and test to the satisfaction of attendiing CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 21 January 2021
Resolved 21 January 2021
Resolution: Entire stern light was replaced with new, Test SAT
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 January 2021
Resolved
2 of the 3 required life floats are damaged and deemed non repairable. Each life float is 22 passenger so passerger count is reduced to 41 to meet the 50 percent required until 2 new life floats are installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 25 January 2021
Resolution: Replaced both life floats with new
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 January 2021
Resolved
Aft life float light is not working. Vessel restricted to daylight hour of operation only until fixed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 25 January 2021
Resolution: Replaced light with new, tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 January 2021
Resolved
Middle life float light is not working properly. Make repair to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 25 January 2021
Resolution: Replaced light with new, Tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 January 2021
Resolved
Middle life float has 1 paddle that is wasted and must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 21 January 2021
Resolution: Brought on a used paddle that was in good condition
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 January 2021
Resolved
front life float needs labeling with the vessels name and passenger count.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 21 January 2021
Resolution: Labeled life float with passenger count and vessels name
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 January 2021
Resolved
Vessel had paper copy of chart with no corrections on it. Garmin GPS was did not have the latest softwhere update. Must make all chart corrections on paper chart since print date or update GPS to lastest softwhere update.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 26 February 2021
Resolution: All Captains have electronic charts on their phone that company pays for. Verified access to charts while in airplane mode (no internet). All SAT
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 January 2021
Resolved
MOB and fire drills are not being logged correctly. Must make new log and start logging all required info for both MOB and fire drills.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 26 February 2021
Resolution: Made new logs that has all required info
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 January 2021
Resolved
Vessel does not have a crew training manual as required. Must make new log for Crew Training and log all info as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 26 February 2021
Resolution: Made new log that has all required info
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 January 2021
Resolved
Strainer for fire pump was leaking water. Must make repairs to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 26 February 2021
Resolution: Installed new seal, all SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2020
Resolved
19 adult PFD are wasted/missing. Renew prior to carrying full passenger count.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2021
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 29 April 2020
Resolved
COD is expired. Provide up to date COD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2020
Resolution: COD was valid, but was lost, owner provided new COD.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 April 2020
Resolved
Life ring buoy grab line are wasted, line and strobe missing. Renew all.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2020
Resolution: New life ring was provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2020
Resolved
Engine room starboard side bilge pump auto is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2020
Resolution: Float switch was renewed and tested all sat.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 29 April 2020
Resolved
Both Fireboy shutdown audible alarm is inoperable. Repair/Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2020
Resolution: New fire boy head unit was provided and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2020
Resolved
All child PFD need new retro.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: All PFDs have received new retro.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 April 2020
Resolved
Middle life float is dark from sun damage. Paint and repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2020
Resolution: Life float has been cleaned and repaired.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 April 2020
Resolved
Anchor light switch is inoperable. Repair/Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2020
Resolution: Anchor light switch was replaced and tested all sat.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 29 April 2020
Resolved
Post radio emergency broadcast placard near VHF.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2020
Resolution: New emergency VHF proceedures placard was provided and posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2020
Resolved
First aid kit is missing. Provide CG approved kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2020
Resolution: New CG approved first aid kit was provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 April 2020
Resolved
Provide up to date light list, coast pilot and tide tables.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2020
Resolution: All required navigation publications were provided.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 December 2018
Resolved
EPIRB hydrostatic release is expired. Provide new release prior to operating beyond 3nm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 December 2018
Resolution: Renewed
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 18 December 2018
Resolved
Fire pumps are not operational. Replace or repair. vessel is restricted to not more than 49 passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 December 2018
Resolution: Repaired or Replaced
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 18 December 2018
Resolved
1 BII fire extinguisher is discharged. Renew or recharge prior to operating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2018
Resolution: Renewed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 December 2018
Resolved
All fire extinguishers must be inspected annually. Provide proof of inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 January 2019
Resolution: Proof of inspection Provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2018
Resolved
Port engine raw water hose after pump is cut almost in two. Renew
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 December 2018
Resolution: Renewed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 December 2018
Resolved
Anchor and stern light are extinguished. Repair/Replace prior to night operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 January 2019
Resolution: Repaired/Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 December 2018
Resolved
27 Adult PFD's are wasted. Passenger count is restricted to not more than 101.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 January 2019
Resolution: Renewed
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 18 December 2018
Resolved
Port steering compartment high level alarm visual is extinguished. Repair/Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 January 2019
Resolution: Repaired/Renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2018
Resolved
Marking for port fuel shut-off value is missing. Replace
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 January 2019
Resolution: ReplaceD
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 18 December 2018
Resolved
Ground in stbd, aft steering compartment is disconnected. Re-attach.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 January 2019
Resolution: Re-attached
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 December 2018
Resolved
Bilge automatic light is not visible from operating station. Provide alternate arrangement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 January 2019
Resolution: Provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 December 2018
Resolved
Provide Coast Pilot and light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 January 2019
Resolution: provided
Fire Fighting › Fire Pumps › Impeller
Issued 19 May 2017
Resolved
Vessel fire pump is inoperable. Replace/repair, Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2017
Resolution: New pump was installed and tested. All sat.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 19 May 2017
Resolved
Vessel COD is expired. Renew COD prior to any operations.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 June 2017
Resolution: New COD was aquired.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 19 May 2017
Resolved
27 adult PFDs are not servicable. Replace PFD prior to carrying more than 100 Passengers
Action required: 705 - Other - as specified
Resolved 2 June 2017
Resolution: NEw PFDs were provided and marked. All sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 May 2017
Resolved
FCC Safety Radio Certificate is expired. Renew.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 2 June 2017
Resolution: New Certificate was provided.
Lifesaving › Lifefloat › Painter
Issued 19 May 2017
Resolved
#3 life float painter line is wasted, renew.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 2 June 2017
Resolution: New Painter was installed.
Navigation › Piloting/Steering › US Coast Pilot
Issued 19 May 2017
Resolved
Vessel navigation publications are out of date. Provide up-to-date pubs and charts.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 2 June 2017
Resolution: New Nav Pubs and charts were provided.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 19 May 2017
Resolved
Vessel drill logs and maintenance logs were not complete. Create new logs that capture the required information.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 2 June 2017