Inspection history · 24
30 March 2026
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8329245
28 April 2025
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8108692
10 July 2024
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7941912
1 November 2023
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7812764
8 June 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7696150
17 May 2022
Administrative Inspection · Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7452234
16 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7451829
18 November 2020
Initial Certification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7302846
22 October 2014
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5009859
18 October 2012
Administration
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 4466876
4 February 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3675408
1 February 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3675361
16 November 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2821984
8 November 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2821626
7 September 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2191078
6 November 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 659113
4 November 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 422377
4 November 1998
Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 804321
10 December 1997
Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 780461
23 October 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 781378
5 September 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 659115
26 August 1997
Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1120564
14 August 1997
Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1119224
22 August 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 881029
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 March 2026
Resolved
Vessels of 12 meters or more in length but less than 50 meters require an all-round light. MI observed missing all-round light. Provide all-round light.
705c: Vessel restricted to daylight operations and limited to 2nm of visibility.
33CFR83.22(b)(v)
Action required: 705 - Other - as specified
Resolved 9 April 2026
Resolution: Vsl Rep emailed photo of working all around light. Light appeared to be tinted but confirmed via plaque on light of visibilty of 2NM.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 March 2026
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or approved cabinet when not in use. MI observed wasted corners on cabinet used for storage. Remove or Replace.
46CFR142.225
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 9 April 2026
Resolution: Vsl Rep sent pictures of removed wasted Flammable Locker from the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 March 2026
Resolved
Towing vessels of 65 feet or less in length must carry at least the minimum number of portable fire extinguishers set forth in table 142.230(a). MI observed 02 extinguishers requiring recharge and a wasted mounting bracket. Provide required number of extinguishers in approved mounting brackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 9 April 2026
Resolution: Fire Extingusher Bracket was replaced with new bracket.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 30 March 2026
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. MI observed failed gasket on pilothouse securing hatch. Replace gasket.
46CFR144.320(b)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 9 April 2026
Resolution: Vsl Rep emailed pictures of a new gasket installed around the weathertight door to the bridge.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 April 2025
Resolved
No later than July 22, 2019, the owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part and include recordkeeping procedures. Health and safety was not present.
46 CFR 140.500(a) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 19 May 2025
Resolution: Health and Safety plan is now onboard the vessel.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 April 2025
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 19 May 2025
Resolution: Vessel replaced vent cover.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 July 2024
Resolved
Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. MI observed the sight glass for the port fuel tank missing guards or protection from breakage.
46CFR144.405
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 15 July 2024
Resolution: Add stainless 1/8 wire top to bottom on fuel sight glass for protection.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 July 2024
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. MI observed the engine room intake vent cover to be deteriorated and the exhaust vent for the engine room to have no cover for closing. Repair engine room intake cover and install engine room exhaust vent cover to satisfaction of MI.
46CFR144.605
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 16 August 2024
Resolution: Received email photos of newly fabricated canvas ventilation covers installed on vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 July 2024
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move and must be either:A flammable liquid storage cabinet that satisfies UL 1275 or a flammable liquid storage cabinet that satisfies FM Approvals Standard 6050. MI observed flammable liquids being stored on the open deck. Provide approved type storage cabinet of sufficient size meeting either of the specific requirements.
46CFR142.225
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 15 July 2024
Resolution: Flammable storage cabinet installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2024
Resolved
All portable fire extinguishers on board the vessel must be inspected or tested at least once every 12 months, as prescribed in paragraphs (a)(1) through (8) of this section. MI observed the portable fire extinguisher located starboard side on deck did not have annual servicing conducted along with the pin to be wasted and seized. Additionally, portable fire extinguisher located in the pilot house had inadequate mounting bracket for the size of the extinguisher.
46CFR142.240(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 19 July 2024
Resolution: Pye Barker serviced extinguisher and installed adequate bracket for pilot house.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2024
Resolved
Each lifebuoy on a towing vessel must: Be approved under approval series 160.050 or 160.150. MI observed the lifebuoy on the starboard side of the pilot house to have a deteriorated grab line and insufficient retro-reflective tape. Repair grab line and install new retro-reflective tape where needed to the satisfaction of MI.
46CFR141.360(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 7 August 2024
Resolution: Lifebuoy replaced with new.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 June 2023
Resolved
Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition.
Marine Inspector observed that 04 bulkhead penetrations in the vessel forepeak were not sealed/watertight.
46 CFR 140.610(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2023
Resolved 5 July 2023
Resolution: Through hole fittings were sealed properly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 May 2022
Resolved
Except as provided in paragraph (a)(8) of this section, each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the following: The system draws power from two sources. Switchover from the primary source to the secondary source may be either manual or automatic.
The fire detection system emergency battery power source was inoperable when tested.
46 CFR 142.330
Action required: 10 - Deficiency Rectified
Due 26 May 2022
Resolved 26 May 2022
Resolution: A third party technician attended the vessel and replaced the battery. The fire detection was tested and operated under two sources of power.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 May 2022
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. Hand-held red flare distress signals, approved under approval series 160.021 or 160.121, and hand-held rocket-propelled parachute red flares, approved under approval series 160.036 or 160.136, are acceptable as both day and night signals.
Found unapproved distress signals onboard.
46 CFR 141.375
Action required: 10 - Deficiency Rectified
Due 26 May 2022
Resolved 26 May 2022
Resolution: The operator replaced the unapproved distress signals with hand-held red flare distress signals, approved under approval series 160.021.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 May 2022
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route.
Identified a wasted weathertight door at the entrance to the deckhouse on the main deck and missing gasket material at the stern entrance to the engine room.
Replace the weathertight door at the entrance to the deckhouse and replace the gaskets in the engine room hatch.
46 CFR 144.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2022
Resolved 14 July 2022
Resolution: The operator purchased a new weathertight door and the door was installed on the deckhouse. The weathertight gaskets were renewed on the engine room stern entrance.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 May 2022
Resolved
Each towing vessel must carry on board and maintain the following: Marine charts or maps of the areas to be transited, published by the National Ocean Service (NOS), the ACOE, or a river authority that satisfy the following requirements: (i) The charts or maps must be of a large enough scale and have enough detail to make safe navigation of the areas possible. The charts or maps must be either - (A) Current editions or currently corrected editions, if the vessel engages in towing exclusively on navigable waters of the U.S., including Western Rivers; or (B) Currently corrected editions, if the vessel engages in towing seaward of navigable waters of the U.S. or more than three nautical miles from shore on the Great Lakes.
Nautical charts required for intended voyage were not onboard.
33 CFR 164.72
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2022
Resolved 2 June 2022
Resolution: MI attended the vessel and verified all nautical charts for the intended voyage were onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 May 2022
Resolved
A COI may be suspended and withdrawn or revoked by the cognizant Officer in Charge, Marine Inspection at any time for noncompliance with the requirements of this subchapter.
Upon administrative review, the vessel is not permitted to operate outside of Routes and Conditions dictated in COI unless a new COI is issued for a Lakes, Bays, and Sounds route which is the designated route the vessel intends to operate on in Tampa Bay, FL.
46 CFR 136.215(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2022
Resolved 26 May 2022
Resolution: USCG Sector St. Petersburg completed a COI on the vessel and issued a full term certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 May 2022
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date.
Upon administrative review, MI found vessel to be past due date for annual inspection. Vessel was required to complete annual inspection by 18FEB21 and 18FEB22. COI is no longer valid.
46 CFR 137.200
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2022
Resolved 26 May 2022
Resolution: USCG Sector St. Petersburg completed a COI on the vessel and issued a full term certificate.
Navigation
Issued 26 August 1997
Resolved
PROVIDE PROPER SIZE BELL.
Condition: Unknown
Due 26 August 1997
Resolved 26 August 1997
Documentation
Issued 26 August 1997
Resolved
PROVIDE OIL DISCHAGE PLACARD.
Condition: Unknown
Due 26 August 1997
Resolved 26 August 1997
Documentation
Issued 26 August 1997
Resolved
PROVIDE RADIO OPERATORS PERMIT.
Condition: Unknown
Due 26 August 1997
Resolved 26 August 1997
Electrical
Issued 14 August 1997
Resolved
PROVIDE COVERS AND GUARDS ON LIGHTING FIXTURES IN ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Accommodation/Occupational Safety
Issued 14 August 1997
Resolved
PROVIDE WASTE MANAGEMENT PLAN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 November 1997
Resolved 14 November 1997
Construction/Loadline
Issued 14 August 1997
Resolved
PROVIDE POLLUTION DISCHARGE PLACARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 November 1997
Resolved 14 November 1997
Electrical
Issued 14 August 1997
Resolved
PROVIDE COVERS FOR ELECTRICAL JUNCTION BOXES (02) IN FOR OVERHEAD OF ENGINEROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997