Records from 2017 to 2026. Most recent: inspection, 30 January 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 20
30 January 2026
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8304007
20 February 2025
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8082477
3 February 2025
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8074102
11 December 2023
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7837707
13 March 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7650253
17 January 2023
Administrative Inspection · Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7624161
12 May 2022
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7386663
27 January 2022
Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7386659
14 October 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7332483
4 May 2021
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7189291
24 January 2020
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6895727
24 January 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6895756
13 March 2019
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6642098
19 June 2018
Administrative Inspection · DAPI Audit · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6437845
12 March 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6370055
3 March 2018
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6375837
11 December 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6322489
19 October 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6316020
16 May 2017
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6176423
5 January 2017
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6066320
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 February 2025
Resolved
A vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less than 24 inches in diameter. Marine Inspector found hole located in 24" ring life buoy. Vessel needsd new 24 inch ring life buoy.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: Vessel replaced with new ring life buoy. all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 February 2025
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—(1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and(2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel only had 6 red hand held flares on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: Vessel procured additional pyrotechnics and placed on board vessel.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 January 2024
Resolved
For fixed gas fire extinguishing systems..;the owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Marine Inspector was notified by owner that fire service company had not supplied servicing report. Supply report to Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2024
Resolved 7 February 2024
Resolution: Vessel owner supplied fire servicing report. MI reviewed and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2024
Resolved
Each life jacket must be marked with Type 1 retroreflective material. Marine Inspector found 01 life jacket with retro material in disrepair. Replace retro material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 7 February 2024
Resolution: Vessel owner supplied pictures of new retro tape. MI reviewed and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2022
Resolved
Vessel has only 6 adult life jackets in working condition.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2022
Resolved 16 May 2022
Resolution: Owner put new child lifejackets onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 January 2022
Resolved
Forward railing loose. Tighten railing. Cleared on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 February 2022
Resolution: Handrail repaired on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2021
Resolved
Satisfactory evidence of required annual servicing for the fire protection equipment must be provided. Yearly maintenance for the Fire Boy and portable extinguishers was not completed. Provide evidence of servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2021
Resolution: Annual servicing document provided (see documents).
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 6 May 2021
Resolved
The Stability Letter must be kept onboard the vessel and be readily available. The Stability Letter was not on vessel. Locate the Stability Letter and place on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 24 May 2021
Resolution: Vessel owner was mailed a copy of the stability letter on record.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2021
Resolved
An exposed hazard such as rotating machinery must be properly protected by a cover, guard or rail. Rotating machinery in the engine compartment did not have a guard. Provide proof of guard installation that would prevent personnel injury in the engine compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2021
Resolution: Machinery guards installed in engine compartment (see documents).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 May 2021
Resolved
A hatch exposed to the weather must be weathertight. Gasket on center compartment hatch was failing. Restore gasket to maintain weathertight protection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 17 May 2021
Resolution: Repaired gasket was viewed over FaceTime, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2020
Resolved
Port fuel tank vent pipe grounding wire broken.
Action required: 10 - Deficiency Rectified
Due 27 February 2020
Resolved 27 February 2020
Resolution: Stripped and reattached wire to through hull fitting.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 January 2020
Resolved
First aid kit contained expired medicines and excessive moisture causing mold.
Action required: 10 - Deficiency Rectified
Due 27 February 2020
Resolved 27 February 2020
Resolution: Replaced first kit with USCG approved assembly. 46 CFR 160.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 24 January 2020
Resolved
Radio emergency broadcast instructions placard faded and unable to be read.
Action required: 10 - Deficiency Rectified
Due 27 February 2020
Resolved 27 February 2020
Resolution: Replaced radio broadcast placard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 March 2019
Resolved
FCC Station license and FCC Safety Certificate not provided.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2019
Resolution: Appropriate FCC certificates were provided
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 June 2018
Resolved
registration has expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2018
Resolved 20 June 2018
Resolution: Vessel provided registration.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 19 June 2018
Resolved
Extinguishers have not been serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2018
Resolved 19 June 2018
Resolution: Extinguishers have been serviced.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 12 March 2018
Resolved
Vessel is missing 2 adult PFD> Renew. Vsl is restricted to not more than 10 pass.
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 26 March 2018
Resolution: New jackets were provided.
Lifesaving › Lifebuoys › Serviceable
Issued 12 March 2018
Resolved
life ring is wasted. replace.
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 19 June 2018
Resolution: Vessel installed new lifering.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 March 2018
Resolved
life ring strobe is missing. provide w 3-6' lanyard
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 19 June 2018
Resolution: Vessel installed new line for waterlight.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 March 2018
Resolved
STBD nav light is extinguished. repair/renew
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 26 March 2018
Resolution: New nav light was installed and tested all sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 March 2018
Resolved
first aid kit is missing contents. provide new kit or renew contents. 46 CFR 160.041
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 26 March 2018
Resolution: New first aid kit was provided.
Documentation › Logs/Records › Logbook (official)
Issued 12 March 2018
Resolved
provide new log for drills and safety maintenance.
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 26 March 2018
Resolution: new logs were created.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 January 2017
Resolved
COMPLETE A CREDIT ANNUAL EXAM TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR VESSEL ANNUAL EXAM IS OVERDUE AS OF 18DEC16
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2017
Resolved 16 May 2017
Resolution: New to Zone/Annual Exam conducted by Sector Maryland-NCR.