FAIRPLAYER is a 2008 freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in February 2025, along with 8 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2025. Most recent: inspection, 7 February 2025.

Built
2008
Last inspected
7 February 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 February 2025
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9371579
992845
Flag
NETHERLANDS
Maury page id
psix-992845

Documentation record

Tonnage as PSIX records it15027 - Convention (Subpart B), Gross Ton
4508 - Convention (Subpart B), Net Ton
21600 - Displacement, Ton
12673 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 8

7 February 2025 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8076556
3 February 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8073573
27 January 2025 PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8069549
14 February 2020 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6896936
29 January 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6896944
2 October 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6270872
4 May 2017 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6128888
6 October 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6013250

Deficiency record · 8

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 27 January 2025 Resolved
This company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. PSCOs observed DG Starboard side was inoperable as of 12DEC2024. Crew made proper notifications to company on 14DEC2024 but no actions taken by company to notify class or flag. Vessel also had inoperable boiler notified to company but notifications were not made to class or flag. After reviewing overdue maintenance multiple items were waiting for company response including PV valve steering gear from January 2024, Gyro compass inoperable steering gear room, leaking ram from free fall lifeboat and other items over due by 30+ days.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2025
Resolved 31 January 2025
Resolution: SEE ATTACHED DOCUMENTS
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 27 January 2025 Resolved
All ships of 500 gross tonnage and upwards shall, in addition to meeting the requirements of paragraph 2.3, with the exception of paragraphs 2.2.3 and 2.3.5, and the requirements of paragraph 2.4, have: A gyro-compass heading repeater, or other means, to supply heading information visually at the emergency steering position if provided. PSCE identified 02 gyro-compass repeaters in steering gear room to be unreadable.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2025
Resolved 31 January 2025
Resolution: SEE ATTACHED DOCUMENTS
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 January 2025 No resolution recorded
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at lease two generating sets. PSCO observed that the port side generator was taken off the vessel at a previous port of call. The vessel currently operating on M/E Generator.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 February 2025 — due date passed with no resolution recorded
Resolution: SEE ATTACHED DOCUMENTS
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 27 January 2025 Resolved
Every ship shall be provided with documentary evidence, to the satisfaction of the Administration, of its fitness to operate with periodically unattended machinery spaces. PSCO observed that there were no written procedures for swapping from the status MANNED to UNMANNED in MMS.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 February 2025
Resolved 31 January 2025
Resolution: SEE ATTACHED DOCUMENTS
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 January 2025 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and constructed adequate for the service for which they are intended... The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. PSCE observed main boiler was inoperable and covered with cardboard and tape. By 07FEB2025.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 February 2025
Resolved 7 February 2025
Resolution: SEE ATTACHED DOCUMENTS
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 January 2025 Resolved
The ring, lines and letter shall be painted in white or yellow on a dark ground... They shall also be permanently marked on the sides of the ships... The marks shall be plainly visible. PSCO observed the deck line painted the same color as the rest of the vessel.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 January 2025
Resolved 27 January 2025
Resolution: SEE ATTACHED DOCUMENTS
Lifesaving › Lifeboat › Carriage Requirement
Issued 6 October 2016 Resolved
The lifeboat engine shall be capable of operating not less than five minutes after starting from cold with the lifeboat out of the water. During exam stern free fall lifeboat was unable to start.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2016
Resolution: Received, reviewed and accepted class report stating that the life proper started.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 6 October 2016 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The six man embakation ladder was not readily available.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 May 2017
Resolution: PSCO's observed presence and proper location of the embarkation ladder for the 6 man liferaft.

Ownership record