MAURY USCG vessel records Sign in
← All vessels

GO ADVENTURER

GO ADVENTURER is a 2011 freight ship. The Coast Guard has recorded 21 inspections since 2010, most recently in February 2026, along with 4 deficiencies and 1 casualty investigation in 2025.

Records from 2010 to 2026. Most recent: inspection, 23 February 2026.

Built
2011
Last inspected
23 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9643087 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDM7780
993157
Flag
UNITED STATES
368237180
Maury page id
psix-993157

Inspections, by type

…with no type recorded1
Years with a record 11 calendar years (2010–2026)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Registered dimensions (L × B × D)169.0 ft × 46.0 ft × 15.0 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)169.0 ft × 46.0 ft × 15.0 ft
ITC tonnagegross 970 / net 291
BuilderMASTER BOAT BUILDERS INC · BAYOU LA BATRE, AL, UNITED STATES · built 2011
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 28 October 2025 · expires 30 November 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it970 - Convention (Subpart B), Gross Ton
97 - Regulatory (Subpart C or D), Gross Ton
291 - Convention (Subpart B), Net Ton
878 - Displacement, Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM7780MMSI 368237180 · active · compulsorily equipped · granted 4 February 2022, expires 4 February 2032
WDH2193MMSI 367509140 · cancelled · compulsorily equipped · granted 9 November 2013, cancelled 13 April 2023 · licensed under a name not among this hull’s recorded names (not shown)
WDF9818MMSI 367509140 · cancelled · compulsorily equipped · granted 8 November 2011, cancelled 4 November 2013 · licensed under a name not among this hull’s recorded names (not shown)
WDF9687MMSI 367507770 · cancelled · compulsorily equipped · granted 25 October 2011, cancelled 7 November 2011 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 21

23 February 2026 MARPOL Annex VI Survey · MARPOL Annex II Examination · MARPOL Annex V Examination · Annual Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8318899
7 November 2025 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8265659
10 June 2025 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8156681
8 May 2025 Administrative Inspection · In-Service Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8131056
1 May 2025 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8127568
14 April 2025 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8112386
12 December 2024 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8052971
29 November 2024 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8041173
25 June 2024 ORV Letter of Designation · Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7934324
30 May 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7923562
4 April 2024 ORV Letter of Designation
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7889973
5 March 2024 In-Service Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · Administrative Inspection · Exemption · MARPOL Annex IV Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7874629
10 August 2023 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7759763
7 March 2022 Construction Oversight · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7407393
16 December 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7369137
17 November 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7353123
18 September 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6553500
14 June 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6175968
24 February 2016 Ballast Water Examination · MTSA Verification · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5820932
9 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4204885
1 March 2010 Construction Oversight · Ballast Water Examination · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3687791

Deficiency record · 4

01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 23 February 2026 Resolved
33 CFR 151.25 (d) Entries shall be made in the oil record book on each occasion. Multiple missing entry's in ORB, provide training to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2026
Resolved 18 March 2026
Resolution: Training conducted, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 13 May 2025 Resolved
Each vessel must have a permanently exhibited, for the guidance of the master and crew members, general arrangement plans. Vessel’s Fire and Safety Plan contained several errors regarding location and type of equipment physically stored onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2025
Resolution: Attended vessel to verify correction of item locations in comparison to fire control plan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 May 2025 Resolved
Where pressure-indicating gauges are used, they must be chosen to be compatible with the pressure to be indicated. The size of the visual display, the fineness of graduations, and the orientation of the display will be considered. In no case must the upper range of the gauge be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. Gauges did not reflect the required no less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2025
Resolution: Vessel rep [name withheld], provided photo documentation of new gauges.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 May 2025 Resolved
Internal combustion engine exhausts, boiler and galley uptakes, and similar sources of ignition shall be kept clear of and suitably insulated from any woodwork or other combustible matter. Exhaust turbochargers for both generators were not installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2025
Resolution: Vessel rep [name withheld], provided photo documentation of lagging on turbo chargers.

Casualty record · 1

14 April 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8112386
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.