PEARL MIST
PEARL MIST is a 2014 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in May 2026, along with 28 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 4 May 2026.
- Built
- 2014
- Last inspected
- 4 May 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 28 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9412701
V7RM9
993382
Flag
MARSHALL ISLANDS
Maury page id
psix-993382
Inspections, by type
…with no type recorded4
Years with a record
9 calendar years (2016–2026)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it5109 - Convention (Subpart B), Gross Ton
1681 - Convention (Subpart B), Net Ton
700 - Dead Weight, Ton
1681 - Convention (Subpart B), Net Ton
700 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 21
4 May 2026
Administrative Inspection · COC-CVE Annual · PSC A · Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8358333
5 May 2025
PSC A · COC-CVE Annual
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8121044
6 May 2024
COC-CVE Annual · PSC A
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7907161
3 May 2023
COC-CVE Annual · PSC A
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7677181
12 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7557306
2 May 2022
PSC B · COC-CVE Initial
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7442364
27 September 2019
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6822256
28 August 2019
COC-CVE Quarterly
Type not classified · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6796115
26 March 2019
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6648845
20 August 2018
COC-CVE Quarterly
Type not classified · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6513031
25 July 2018
Type not recorded
No type recorded · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6491165
12 March 2018
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6368513
18 July 2017
COC-CVE Quarterly · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6212788
11 May 2017
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6143940
28 March 2017
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6112774
16 February 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6089766
12 January 2017
Ballast Water Examination · ISPS II Exam · Deficiency Check · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6069731
15 October 2016
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6022887
1 July 2016
Type not recorded
No type recorded · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 5931269
21 April 2016
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5859098
26 January 2016
Ballast Water Examination · ISPS III Exam · COC-CVE Quarterly · NPV Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5803583
Deficiency record · 28
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 May 2026
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. During the life raft deployment, as the cradle opened, the stainless steel wire used for the hand brake parted and was thrown on deck. This action rendered the self lowering cable inoperable.
Cite: 74 SOLAS 20 III/20.2
Code: 17bc
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 May 2026
Resolved
The arrangements for the ready availability of water supply shall be in passenger ships of 1,000 gross tonnage and upwards such that at least one effective jet of water is immediately available from any hydrant in an interior location and so as to ensure the continuation of the output of water by the automatic starting of one required fire pump. PSCO observed a lack of ready availability of water supply due to the fire fighting pump being placed in manual mode. This was listed as a part of the vessel's procedures.
Cite: 74 SOLAS 20 II-2/10.2.1.2
Code: 17bc
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 4 May 2026
Resolved
Fire detection and fire alarm systems, shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed a glove covering the smoke detector in the potable water pump room.
Cite: 74 SOLAS 20 II-2/14.2.1.1.2
Code: 17bc
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 May 2026
Resolved
Openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed fire door 110 unable to latch closed.
Cite: 74 SOLAS 20 II-2/9.4.1.1.1
Code: 16bc
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 May 2026
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed materials improperly stowed in potable water tank space that does not have active fire suppression.
Cite: 74 SOLAS 20 II-2/9.2.2.3.2.2
Code: 16bc
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 May 2026
Resolved
Fire doors in main vertical one bulkheads, galley boundaries and stairway enclosrues, the approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10 s from the beginning of their movement. PSCO observed the starboard forward dining room door that was located in main vertical zone to close in less than 10 seconds.
Cite: 74 SOLAS II-2/9.4.1.1.5.2
Code: 16bc
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 May 2025
Resolved
All Life-saving appliances and arrangements shall comply with the applicable requirements of the code. All life-saving applilances shall be fitted with retro-reflective material where it will assist in detection. Portside lifeboat missing some retro-reflective material (4 pieces) from the outboard facing side.
74SOLAS20 III/34
LSA Code 1.2.2.2.7
10c
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 6 May 2024
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Stairwell guide located on deck 05 center stair was not familiar with their emergency duties.
74 SOLAS 20 III/19.2.1
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2024
Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights, not less than two of these shall also be provided with lifebuoy self-activating smoke signals and be capable of quick release from the navigation bridge. Self-igniting light on lifebuoy on deck 5 aft port deck was inoperable.
74 SOLAS 20 III/7.1.3
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 May 2023
Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. The following doors failed to close upon testing: 4/10, 4/11, FSD 3T and 31, Cabin 339, and Bridge Entry Door. 74 SOLAS 20 II-2/9.4.1.1.2.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 May 2023
Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks of passenger ships, the minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 9.1 and 9.2. Engine control room is listed as a category 10 space. Space has numerous combustibles stored in it and no fire suppression is installed. 74 SOLAS 20 II/2/9.2.2.3.1.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 May 2023
Resolved
Fixed fire-extinguishing systems shall be installed having due regard to the fire growth potnetial of the protected spaces. Cold garbage storage room nozzles ampules were empty and not in working order. 74 SOLAS 20 II-2/10.1.1.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 3 May 2023
Resolved
A ship must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuouss place in each machinery space, or at the bilge and ballast pump control station. Oil discharge placard missing from both bunker stations. 33CFR155.450
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 3 May 2023
Resolved
The steering gear compartments arrangements shall include handrails and grating or other nonslip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. Steering gear compartment missing non-stick surfaces in way of steering gear and steering gear controls. 74 SOLAS 04 II-1/29.13.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2023
Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Combustible waste receptacles found in galley and outside garbage cold storage room. 74 SOLAS 20 II-2/4.4.2.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 May 2023
Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. FSD 1/7 in galley leading to chemical stores failed to close and latch. 74 SOLAS 20 II-2/9.4.1.1.2
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2022
Resolved
07113- Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. When tested, of 06 total section valves, 4, 5, and 6 did not correctly indicate on bridge panel. Section valves 1, and 2 could not be tested at time of exam. 74 SOLAS 20 II-2/14.2.1.2 - 17ac
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 May 2022
Resolved
07105- Closure times for fire doors in main vertical zone bulkheads shall be no more than 40 seconds and no less than 10 seconds from the beginning of their movement. Fire screen door MV closed in under 10 seconds. 74 SOLAS 20 II-2/9.4.1.1.5.2 - 16ac
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 May 2022
Resolved
07105- Doors shall be self closing. Two fire doors in crew mess found with inoperable latches. 74 SOLAS 20 II-2/9.4.1.1.5.1. 16ac
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 May 2022
Resolved
07109- Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler, fire detection and fire alarm systems of an approved type complying with the requirements of the Fire Safety Code in all control stations, accommodation and service spaces, including corridors and stairways. Sprinkler head in Fire Locker No. 2, Deck 5, Aft, blocked by overhead framing. 74 SOLAS 20 II-2/10.6.1- 16ac
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Compliance (COC)
Issued 26 March 2019
Resolved
CG002- Certificates & Documentation- Foreign vessels of countries which are signatory to the International Convention for the Safety of Life at Sea, 1974, are issued a Certificate of Compliance(CG-3585). Vessels Certificate of Compliance expired 12MAR2019 and the vessel embarked 161 passengers in Port Everglades on 16MAR2019.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Compliance (COC)
Issued 26 March 2019
Resolved
CG002- Certificates & Documentation- Each vessel subject to inspection under this part shall undergo an initial inspection for certification before being put into service. After being put into service—(1)each passenger vessel, nautical school vessel, and small passenger vessel allowed to carry more than 12 passengers on a foreign voyage shall be inspected at least once a year. Vessels Certificate of Compliance expired 12MAR2019 and the vessel embarked U.S. passengers in Port Everglades on 16MAR2019.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 March 2018
Resolved
0750 - A Class divisions formed by bulkheads and decks shall be constructed as to be able of preventing the passage of smoke and flame. Fire screen door 3Q on deck three has a two inch corroded penetration in door coaming compromising fire integrity. SOLAS Cons. 2014 II-2/3
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 12 March 2018
Resolved
2035 - Fire control plans shall be kept up to date. Emergency exit displayed on fire control plan in Assembly Area I leads directly to the bridge. SOLAS Cons. 2014 II-2/15.2.4
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 18 July 2017
Resolved
Main and emergency switch boards shall be arranged to give easy access as may be needed with nonconducting mats provided at the rear of the switchboards. Area behind switch board used as storage space and no mat provided. - SOLAS 2009 II-1/45.2
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 18 July 2017
Resolved
Fixed fire detection and fire alram system installation shall be suitable for the nature of the space and fire growth potential. Storage of combustible materials in the space behind dyers without fire detection or supression. - SOLAS 2009 II-2/7.1.1
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 13 January 2017
Resolved
0750 - Fire Prevention - Flammable liquids must be stowed in cat (14) spaces. Aft mooring deck located on deck 2 (cat 5) found with a large quantity of flammable liquids. 3 flammable liquid lockers found with more than daily use quantities and storage was not reflected on fire control plan. 74SOLAS(2014 con.)CH II-2/9.2.2.3.2.2(14)
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 26 January 2016
Resolved
0750-The approximate time of closure for hinged fire doors shall be no more than 40 seconds and no less than 10 seconds from the beginning of their movement with the ship in upright position. 03 fire screen door foun to close outside the allowed closure time. - SOLAS 74 cons 14 II-2/19.4.1.1.5.3 - 10c
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,