PEARL MIST is a 2014 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in May 2026, along with 28 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 4 May 2026.

Built
2014
Last inspected
4 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9412701
993382
Flag
MARSHALL ISLANDS
Maury page id
psix-993382

Inspections, by type

…with no type recorded4
Years with a record 9 calendar years (2016–2026)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it5109 - Convention (Subpart B), Gross Ton
1681 - Convention (Subpart B), Net Ton
700 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 21

4 May 2026 Administrative Inspection · COC-CVE Annual · PSC A · Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8358333
5 May 2025 PSC A · COC-CVE Annual
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8121044
6 May 2024 COC-CVE Annual · PSC A
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7907161
3 May 2023 COC-CVE Annual · PSC A
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7677181
12 September 2022 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7557306
2 May 2022 PSC B · COC-CVE Initial
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7442364
27 September 2019 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6822256
28 August 2019 COC-CVE Quarterly
Type not classified · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6796115
26 March 2019 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6648845
20 August 2018 COC-CVE Quarterly
Type not classified · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6513031
25 July 2018 Type not recorded
No type recorded · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6491165
12 March 2018 ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6368513
18 July 2017 COC-CVE Quarterly · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6212788
11 May 2017 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6143940
28 March 2017 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6112774
16 February 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6089766
12 January 2017 Ballast Water Examination · ISPS II Exam · Deficiency Check · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6069731
15 October 2016 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6022887
1 July 2016 Type not recorded
No type recorded · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 5931269
21 April 2016 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5859098
26 January 2016 Ballast Water Examination · ISPS III Exam · COC-CVE Quarterly · NPV Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5803583

Deficiency record · 28

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 May 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. During the life raft deployment, as the cradle opened, the stainless steel wire used for the hand brake parted and was thrown on deck. This action rendered the self lowering cable inoperable. Cite: 74 SOLAS 20 III/20.2 Code: 17bc
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2026
Resolved 4 May 2026
Resolution: PSCO witnessed replacement of the stainless steel wire before departing the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 May 2026 Resolved
The arrangements for the ready availability of water supply shall be in passenger ships of 1,000 gross tonnage and upwards such that at least one effective jet of water is immediately available from any hydrant in an interior location and so as to ensure the continuation of the output of water by the automatic starting of one required fire pump. PSCO observed a lack of ready availability of water supply due to the fire fighting pump being placed in manual mode. This was listed as a part of the vessel's procedures. Cite: 74 SOLAS 20 II-2/10.2.1.2 Code: 17bc
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2026
Resolved 4 May 2026
Resolution: Training was given to the engineering crew to instruct them to ensure the fire fighting pump remains in automatic mode.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 4 May 2026 Resolved
Fire detection and fire alarm systems, shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed a glove covering the smoke detector in the potable water pump room. Cite: 74 SOLAS 20 II-2/14.2.1.1.2 Code: 17bc
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2026
Resolved 4 May 2026
Resolution: Glove was removed from the smoke detector.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 May 2026 Resolved
Openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed fire door 110 unable to latch closed. Cite: 74 SOLAS 20 II-2/9.4.1.1.1 Code: 16bc
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 4 May 2026
Resolution: Adjustments were made to the door to allow it to latch closed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 May 2026 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed materials improperly stowed in potable water tank space that does not have active fire suppression. Cite: 74 SOLAS 20 II-2/9.2.2.3.2.2 Code: 16bc
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 6 May 2026
Resolution: All combustibles removed from space, confirmed by attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 May 2026 Resolved
Fire doors in main vertical one bulkheads, galley boundaries and stairway enclosrues, the approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10 s from the beginning of their movement. PSCO observed the starboard forward dining room door that was located in main vertical zone to close in less than 10 seconds. Cite: 74 SOLAS II-2/9.4.1.1.5.2 Code: 16bc
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 5 May 2026
Resolution: Adjustments were made to the door to slow the closing time.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 May 2025 Resolved
All Life-saving appliances and arrangements shall comply with the applicable requirements of the code. All life-saving applilances shall be fitted with retro-reflective material where it will assist in detection. Portside lifeboat missing some retro-reflective material (4 pieces) from the outboard facing side. 74SOLAS20 III/34 LSA Code 1.2.2.2.7 10c
Action required: 10 - Deficiency Rectified
Due 5 May 2025
Resolved 5 May 2025
Resolution: The vessels crew was able to replace the missing retro-reflective material and was in good working order prior to our departure from the vessel.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 6 May 2024 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Stairwell guide located on deck 05 center stair was not familiar with their emergency duties. 74 SOLAS 20 III/19.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 May 2024
Resolution: Crew member was trained on the spot and their emergency duties were switched.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2024 Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights, not less than two of these shall also be provided with lifebuoy self-activating smoke signals and be capable of quick release from the navigation bridge. Self-igniting light on lifebuoy on deck 5 aft port deck was inoperable. 74 SOLAS 20 III/7.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 May 2024
Resolution: Battery replaced
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 May 2023 Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. The following doors failed to close upon testing: 4/10, 4/11, FSD 3T and 31, Cabin 339, and Bridge Entry Door. 74 SOLAS 20 II-2/9.4.1.1.2.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 June 2023
Resolved 3 May 2023
Resolution: Witnessed satisfactory close of doors after crew made adjustments.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 May 2023 Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks of passenger ships, the minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 9.1 and 9.2. Engine control room is listed as a category 10 space. Space has numerous combustibles stored in it and no fire suppression is installed. 74 SOLAS 20 II/2/9.2.2.3.1.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2023
Resolved 1 June 2023
Resolution: Vessel sent sufficient evidence that the space was cleared of combustibles in the space.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 May 2023 Resolved
Fixed fire-extinguishing systems shall be installed having due regard to the fire growth potnetial of the protected spaces. Cold garbage storage room nozzles ampules were empty and not in working order. 74 SOLAS 20 II-2/10.1.1.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 June 2023
Resolved 3 May 2023
Resolution: Witnessed satisfactory replacement.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 3 May 2023 Resolved
A ship must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuouss place in each machinery space, or at the bilge and ballast pump control station. Oil discharge placard missing from both bunker stations. 33CFR155.450
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 June 2023
Resolved 3 May 2023
Resolution: New placard was mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 3 May 2023 Resolved
The steering gear compartments arrangements shall include handrails and grating or other nonslip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. Steering gear compartment missing non-stick surfaces in way of steering gear and steering gear controls. 74 SOLAS 04 II-1/29.13.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2023
Resolved 18 May 2023
Resolution: Vessel sent photographic evidence, adding grating and non stick floor paint to steering gear/steering gear control area.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2023 Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Combustible waste receptacles found in galley and outside garbage cold storage room. 74 SOLAS 20 II-2/4.4.2.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2023
Resolved 18 May 2023
Resolution: Vessel sent photographic evidence of employing non combustible waste recepticles in galley and cold storage room.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 May 2023 Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. FSD 1/7 in galley leading to chemical stores failed to close and latch. 74 SOLAS 20 II-2/9.4.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 June 2023
Resolved 3 May 2023
Resolution: Witnessed satisfactory closing of door.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2022 Resolved
07113- Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. When tested, of 06 total section valves, 4, 5, and 6 did not correctly indicate on bridge panel. Section valves 1, and 2 could not be tested at time of exam. 74 SOLAS 20 II-2/14.2.1.2 - 17ac
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2022
Resolved 6 May 2022
Resolution: Witnessed satisfactory test of ALL 6 section valves. ALL Sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 May 2022 Resolved
07105- Closure times for fire doors in main vertical zone bulkheads shall be no more than 40 seconds and no less than 10 seconds from the beginning of their movement. Fire screen door MV closed in under 10 seconds. 74 SOLAS 20 II-2/9.4.1.1.5.2 - 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 6 May 2022
Resolution: Witnessed satisfactory closure times for FSD MV. ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 May 2022 Resolved
07105- Doors shall be self closing. Two fire doors in crew mess found with inoperable latches. 74 SOLAS 20 II-2/9.4.1.1.5.1. 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 6 May 2022
Resolution: Verified that latches were replaced. ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 May 2022 Resolved
07109- Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler, fire detection and fire alarm systems of an approved type complying with the requirements of the Fire Safety Code in all control stations, accommodation and service spaces, including corridors and stairways. Sprinkler head in Fire Locker No. 2, Deck 5, Aft, blocked by overhead framing. 74 SOLAS 20 II-2/10.6.1- 16ac
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 6 May 2022
Resolution: Vessel removed overhead framing that blocked the sprinkler head. Overhead framing now 21 cm from head. ALL SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Compliance (COC)
Issued 26 March 2019 Resolved
CG002- Certificates & Documentation- Foreign vessels of countries which are signatory to the International Convention for the Safety of Life at Sea, 1974, are issued a Certificate of Compliance(CG-3585). Vessels Certificate of Compliance expired 12MAR2019 and the vessel embarked 161 passengers in Port Everglades on 16MAR2019.
Action required: 10 - Deficiency Rectified
Due 26 March 2019
Resolved 7 May 2022
Resolution: Closing old deficiency. Vessel has received valid COC 06MAY2022 after 2 years of not operating.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Compliance (COC)
Issued 26 March 2019 Resolved
CG002- Certificates & Documentation- Each vessel subject to inspection under this part shall undergo an initial inspection for certification before being put into service. After being put into service—(1)each passenger vessel, nautical school vessel, and small passenger vessel allowed to carry more than 12 passengers on a foreign voyage shall be inspected at least once a year. Vessels Certificate of Compliance expired 12MAR2019 and the vessel embarked U.S. passengers in Port Everglades on 16MAR2019.
Action required: 10 - Deficiency Rectified
Due 27 March 2019
Resolved 27 March 2019
Resolution: COC Exam was completed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 March 2018 Resolved
0750 - A Class divisions formed by bulkheads and decks shall be constructed as to be able of preventing the passage of smoke and flame. Fire screen door 3Q on deck three has a two inch corroded penetration in door coaming compromising fire integrity. SOLAS Cons. 2014 II-2/3
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 10 April 2018
Resolution: Class report received attesting to crop and renew of corroded area.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 12 March 2018 Resolved
2035 - Fire control plans shall be kept up to date. Emergency exit displayed on fire control plan in Assembly Area I leads directly to the bridge. SOLAS Cons. 2014 II-2/15.2.4
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 10 April 2018
Resolution: Class report attesting to escape route on fire control plan changed to satisfy emergency exit requirements.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 18 July 2017 Resolved
Main and emergency switch boards shall be arranged to give easy access as may be needed with nonconducting mats provided at the rear of the switchboards. Area behind switch board used as storage space and no mat provided. - SOLAS 2009 II-1/45.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 18 August 2017
Resolution: Provided pictures of storage removed and mat added.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 18 July 2017 Resolved
Fixed fire detection and fire alram system installation shall be suitable for the nature of the space and fire growth potential. Storage of combustible materials in the space behind dyers without fire detection or supression. - SOLAS 2009 II-2/7.1.1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 18 July 2017
Resolution: Corrected on the spot.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 13 January 2017 Resolved
0750 - Fire Prevention - Flammable liquids must be stowed in cat (14) spaces. Aft mooring deck located on deck 2 (cat 5) found with a large quantity of flammable liquids. 3 flammable liquid lockers found with more than daily use quantities and storage was not reflected on fire control plan. 74SOLAS(2014 con.)CH II-2/9.2.2.3.2.2(14)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 16 February 2017
Resolution: Area was cleared from additional flammable materials and dry powder fire extinguisher added near paint locker on deck.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 26 January 2016 Resolved
0750-The approximate time of closure for hinged fire doors shall be no more than 40 seconds and no less than 10 seconds from the beginning of their movement with the ship in upright position. 03 fire screen door foun to close outside the allowed closure time. - SOLAS 74 cons 14 II-2/19.4.1.1.5.3 - 10c
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 January 2016
Resolved 26 January 2016
Resolution: the fire screen doors were repaired during the COC exam.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.