MAURY USCG vessel records Sign in
← All vessels

AXIOS STAR

AXIOS STAR is a 2008 tank ship. The Coast Guard has recorded 18 inspections since 2008, most recently in June 2026, along with 6 deficiencies and 6 operational controls.

Records from 2008 to 2026. Most recent: operational control imposed, 12 June 2026.

Built
2008
Last inspected
12 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9407366 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
993493
Flag
LIBERIA
—
Maury page id
psix-993493

Inspections, by type

…with no type recorded5
Years with a record 10 calendar years (2008–2026)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29828 - Convention (Subpart B), Gross Ton
60731 - Displacement, Metric Ton
49996 - Dead Weight, Metric Ton
13429 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 18

12 June 2026 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8403131
19 May 2026 Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8376363
6 November 2025 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8261576
1 November 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8261739
28 November 2023 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7830360
22 August 2019 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6790463
26 May 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6694319
2 May 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6675519
12 September 2018 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6538787
11 April 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6384511
24 August 2017 MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6248689
11 July 2017 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6205362
9 June 2017 NPV Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6170460
5 June 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6166519
28 September 2016 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6011254
14 August 2015 COC-CHEM & TVE Renew · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5215732
23 February 2011 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3950838
29 December 2008 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3385809

Deficiency record · 6

Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 20 August 2015 Resolved
2550-Maintenance of ship & equipment-A ship is subject to the control by officers when there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to the safety of ships. PSCO discovered port & starboard side liferafts stowed w/ the painter line attached to the cradle rendering the float free arrangement inoperative.-74 SOLAS XI-1/4.1
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2015
Resolved 21 August 2015
Resolution: ABS surveyor boarded vessel and verified proper float free arrangement of port and starboard liferafts. Additionally vessel''s superintendent boarded and provided training to the ship''s crew on how to properly stow and secure the vessel''s liferafts.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 20 August 2015 Resolved
0610-Lifeboats-Chemical tankers and gas carriers carrying cargoes emitting toxic vapours or gases shall carry, lifeboats with a self-contained air support system complying with the requirements of section 4.8 of the Code. PSCO discovered the air regulator valve knob in the starboard side lifeboat stripped rendering the lifeboats air support system inoperative.-74 SOLAS III/31.1.6 & LSA Code 4.8
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2015
Resolved 21 August 2015
Resolution: An ABS surveyor boarded the vessel and verified that the air regulator valve was properly repaired. The knob and spindle valve were provided with a safety pin, the starboard lifeboat''s air support system is now operational.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 20 August 2015 Resolved
1410-Propulsion Main Engine-Means shall be provided to control leaks of flammable liquids. PSCO observed an oil leak on the ships main engine #1 fuel pump. Vessel is prohibited from using this fuel pump until the leak has been properly repaired.-74 SOLAS II-2/4.1
Action required: 705 - Other - as specified
Due 3 September 2015
Resolved 21 August 2015
Resolution: An ABS surveyor boarded the vessel and verified that the main engine #1 fuel pump was overhauled by the vessel''s crew. No evidence of an oil leak from the main engine #1 was observed during this visit.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 14 August 2015 Resolved
1410-Propulsion Main Engine-After any survey of the ship has been completed, no change shall be made in the structural arrangements, machinery, equipment, etc. PSCO observed jacket water leak on the #2 cylinder on the main engine.-74 SOLAS I/11
Action required: 705 - Other - as specified
Due 20 September 2015
Resolved 24 August 2015
Resolution: During the attendance period the surveyor carried out a visual examination of the main engine #2 cylinder including its jacket water system, it was noticed that was noticed that the main engine was operating within its normal parameter.
Lifesaving › Inflatable Liferafts › Float Free
Issued 14 August 2015 Resolved
0628-Stowage of Liferafts-Each liferaft or group of liferafts shall be stowed with a float free arrangement complying with the requirements of the paragraph 4.1.6 of the Code. PSCO observed the painter lines on both port and starboard side liferafts attached directly to the deck welded cradle, preventing the proper operation of the float free arrangement.-74 SOLAS III/13.4.2
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2015
Resolved 20 August 2015
Resolution: The ship’s crew corrected the painter arrangements on the spot in accordance with manufacturers installation instructions.
Documentation › Certificates/Documents › IOPP Certificate
Issued 14 August 2015 Resolved
1799-Other After any survey of the ship has been completed, no change shall be made in the structure, equipment, systems, fittings, arrangements or material covered by the survey, w/o the sanction of the administration. Vessel has a slop tank designated as a residual tank (cap. 99 cubic meters) that is used for tank washing residues & not listed under section 6.2 of the IOPP-MARPOL Annex I/6.4.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 August 2015
Resolved 21 August 2015
Resolution: An ABS surveyor boarded the above mentioned vessel and verified the approved onboard tanks in relationship to the residual tank. Upon completion of the research, the IOPP Form B was amended in order to reflect the additional compartment.

Ownership record