Records from 2016 to 2026. Most recent: inspection, 17 February 2026.
Inspection history · 16
17 February 2026
PSC B
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8310746
26 March 2025
PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8100330
5 March 2024
PSC B
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7874193
18 June 2023
PSC B
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7715424
23 January 2023
Ballast Water Examination · PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7625986
12 July 2022
ISPS Exam · Ballast Water Examination · PSC B
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7502711
25 January 2022
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7385120
1 December 2021
Ballast Water Examination · PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7357756
16 June 2021
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7227689
5 May 2021
Ballast Water Examination · PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7186699
6 October 2020
PSC B · Ballast Water Examination · ISPS Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7069827
11 October 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6827928
2 November 2018
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6573682
26 September 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6545368
15 August 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6236899
3 August 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5958918
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 1 December 2021
Resolved
Refractory door on the incinerator was missing the gasket, vessel crew did not have proper temperature rated gasket adhesive.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 January 2022
Resolution: Received manufacturer and class reports attesting to proper incinerator operation without a gasket installed on teh refractory door.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 5 May 2021
Resolved
CARGO PORTS AND OTHER OPENINGS IN THE SIDES OF SHIPS BELOW THE FREEBOARD SHALL BE FITTED WITH DOORS SO DESIGNED AS TO ENSURE WATERTIGHTNESS.
SIDE CARGO RAMP GASKET HAS OBVIOUS LIGHT LEAK AND GAP OF APPROX. 3MM, BELOW THE FREEBOARD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2021
Resolution: Vessel received condition from class to sail to next port for repair verification.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2021
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGERTO THE SHIP OR PERSONS ON BOARD.
PSCO OBSERVED EVIDENCE OF CHARRING AND COMPROMISE OF INCINERATOR INSULATION.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 June 2021
Resolution: Reviewed rectified class condition.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 September 2018
Resolved
CODE: 0715 - The function of fixed fire detection and fire alarm system shall be periodically tested to the satisfaction of the administration by means of equipment producing hot air at the appropriate temperature or other phenomena associated with incipient fires to which the detector is designed to respond.
Vessel does not have equipment to test heat and flame detectors.
74SOLAS(04)II-2/7.2.3; 40A/C
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 October 2018
Resolved 7 November 2018
Resolution: Equipment to test heat and flame detectors has been on board vessel since 2013, a new testing equipment of infrared flame detector and UV flame detector was also provided, and function of testing equipment was carried out and found in good condition.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 September 2018
Resolved
CODE: 0900 - The machinery and other associated piping shall be of a design and construction adequate for the service for when they are constructed as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards.
Incinerator has a 7cm crack on upper right corner, 3cm crack on upper left and 2cm crack on lower left corners of housing on lower door.
73SOLAS(04)II-1/26.1 - 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 October 2018
Resolved 7 November 2018
Resolution: The cracks in the corners of the vessel's incinerator were confirmed to be satisfactory grinded off and welded. Sastifactory operational test of generator was conducted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 September 2018
Resolved
CODE: 0900 - After survey of the ship has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items without the sanction of the Administration.
STBD anchor wash line has an unauthorized patch. The Master and C/E were unaware of repair.
74SOLAS(04)I/11 - 40A/C
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 October 2018
Resolved 7 November 2018
Resolution: The starboard anchor wash line was confirmed that the holed part of the line was repaired by welding. A general examination of the repair was conducted with satisfactory results.