EVGENIA S is a 2008 tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in May 2026, along with 4 deficiencies and 2 operational controls.
Records from 2016 to 2026. Most recent: inspection, 13 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it29605 - Convention (Subpart B), Gross Ton 46610 - Dead Weight, Metric Ton 56257 - Displacement, Metric Ton 11921 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
13 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 13
13 May 2026Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8372371
20 April 2026PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8349970
11 June 2024PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7932311
18 August 2022COC-CHEM Renew
Type not classified · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7534056
29 March 2020COC-CHEM & TVE Renew · Administrative Inspection · PSC B
...The manual shall have a standard format in compliance with appendix 4 to this Annex. (Appendix 4, section 4.5). P & A Manual is missing update regarding persistent floaters. (MEPC.315(74))
MARPOL II/14.1
50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2026
Resolved 13 May 2026
Resolution: PSC NOLA received a P&A Manual update from RINA satisfying the requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 April 2026Resolved
Each survival craft shall be stowed fully equipped as required by this chapter and the Code. PSCO's observed a leak in the Port Side lifeboat self contained air support system. Vessel's crew rectified onboard.
74 SOLAS (cons.) III/13.4, LSA Code 4.8
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 April 2026
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 June 2024Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarms systems. Smoke detector in purifier space did not work
74SOLAS(20)II-2/14.2.1.1.2
17C Cleared
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2024
Resolved 11 June 2024
Resolution: Fire alarm replaced.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 2 May 2019Resolved
In accordance with The Code means shall be provided for measuring the cargo temperature. Vessel's cargo temperature measuring system displays a "IO terminal Bus 1 ground fail" and the crew was not able to identify the source of that alarm. SOLAS (2014) VII/10.1 IBC Code (2016) CH. 7.1.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2019
Resolved 3 May 2019
Resolution: Vessel's Classification Society provided report from surveyor detailing the crews' actions and the vessel's plan moving forward.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.