Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
2156 - Convention (Subpart B), Gross Ton
1338 - Convention (Subpart B), Net Ton
Maury page id
psix-994267
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 24
18 June 2025Deficiency Check · Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8153517
26 February 2025Bulk Liquid Transfer Monitor
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8085779
22 October 2024Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8022704
22 June 2024Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7950523
28 November 2023MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7830303
30 June 2023Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7727324
30 May 2023Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7700423
28 November 2022Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7601745
13 July 2021Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7591749
15 October 2020MTSA/ISPS Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7078333
7 October 2020Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7073497
21 September 2020Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7062549
2 September 2020Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7048055
29 April 2020Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6945666
9 January 2020Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6886061
16 July 2019MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6751611
11 September 2018Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6537624
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 November 2022Resolved
Ventilation intakes to machinery should be so arranged as to prevent the flow of cargo vapor. STBD pump engine room ventilation was missing gasket material on inboard door. 46CFR38.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 December 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 November 2022Resolved
Remote manual shutdown station shall be conspicuously marked. Remote pump shutdown station has sign that is faded and no longer readable. Re-paint or replace sign to properly identify shutdown station. 46CFR32.50-35(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 December 2022
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 October 2020Resolved
(a) Each cargo tank of a tankship must be equipped with an intrinsically safe high-level alarm and a tank overfill alarm.
(b) If installed after July 23, 1990, the high-level alarm and tank overfill alarm required by paragraph (a) must -
(2) Activate an alarm in the event of loss of power to the alarm system.
When power was cut to the high/overfill alarm panel, no alarm sounded or was visually present.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2020
Resolved 24 November 2020
Resolution: [name withheld] attended vessel and confirmed alarm functions properly.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 July 2019Resolved
(2) Activate an alarm in the event of loss of power to the alarm system.
High and overfill level alarm panel fail to activate an alarm when it lost power.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 July 2019
Resolution: The Alarm was visible in the panel.