MAURY USCG vessel records
← All vessels

CAPE TAFT

CAPE TAFT is a 2008 tank ship. The Coast Guard has recorded 32 inspections since 2016, most recently in April 2026, along with 5 deficiencies and 7 operational controls.

Records from 2016 to 2026. Most recent: inspection, 20 April 2026.

Built
2008
Last inspected
20 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 April 2026
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9401221
994316
Flag
MARSHALL ISLANDS
Maury page id
psix-994316

Documentation record

Tonnage as PSIX records it42010 - Convention (Subpart B), Gross Ton
73711 - Dead Weight, Metric Ton
89321 - Displacement, Metric Ton
22454 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

32 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; 7 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

20 April 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8352722
1 April 2026 COE-Administrative
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8340385
31 March 2026 COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8338567
13 February 2026 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8310105
10 February 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8308675
7 January 2026 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8291655
11 February 2025 COC-CHEM & TVE Annual
Type not classified · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8073154
14 November 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8035062
27 March 2024 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7886548
25 March 2024 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7884767
11 March 2024 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7874927
6 March 2024 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7875037
6 March 2024 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7875147
1 February 2024 PSC B · COE-Administrative · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7855812
31 January 2024 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7855545
23 March 2023 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7649162
16 January 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7378993
2 December 2021 Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7361103
25 February 2021 COC-CHEM & TVE Annual · PSC B · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7144350
6 October 2020 In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7073922
16 July 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7008066
15 January 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6888115
3 January 2020 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6880290
13 June 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6712851
22 April 2019 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6665936
18 April 2019 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6665701
12 August 2018 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6508858
8 August 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6504469
30 July 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6220818
17 March 2017 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6106837
17 February 2017 COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6086468
5 August 2016 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5959887

Deficiency record · 5

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2023 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect, e.g. in compartments assigned principally to accumulator batteries, in paint lockers, acetylene stores or similar spaces, unless the Administration is satisfied that such equipment is: appropriately certified for safe usage in the dusts, vapours or gases likely to be encountered. Explosion proof light fixture found on deck three of cargo pump room had a broken electrical fitting and was not explosion proof.
Action required: 10 - Deficiency Rectified
Due 23 March 2023
Resolved 24 March 2023
Resolution: Vessel replaced explosion proof light fixture.
14 - Pollution Prevention › 148 - Ballast Water › Ballast water report
Issued 2 December 2021 Resolved
Vessel incorrectly completed the NBIC ballast water report stating a drydock had been completed when in fact it was a UWILD.
Action required: 10 - Deficiency Rectified
Due 2 December 2021
Resolved 2 December 2021
Resolution: Vessel submitted new NBIC email to correct error.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 August 2018 Resolved
The High-level Alarm must activate visable and audible alarm so that is can be seen and heard on the vessel where cargo transfer is controlled. Vessel did not have a functioning visable high level alarm. 46CFR 39.2007(c)(3)
Action required: 10 - Deficiency Rectified
Due 12 August 2018
Resolved 12 August 2018
Resolution: Vessel repaired light
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 August 2018 Resolved
The High level alarm and the overfill alarm must be identified in black letters at least 2 inches high on white background with the legends "High Level Alarm" and "Tank Overfill Alarm". Both alarms were in red lettering. 46CFR39.2007(c)(2)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 12 August 2018
Resolved 12 August 2018
Resolution: Painted in black letters
Lifesaving › Inflatable Liferafts › Painter
Issued 5 August 2016 Resolved
All four liferafts were found on an assembly arrangement which prohibits them from a float free arangement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2016
Resolved 6 August 2016
Resolution: Vessel installed painter line properly after direction from the attending Coast Guard Marine Inspector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.