MAURY USCG vessel records
← All vessels

STOLT SNELAND

STOLT SNELAND is a 2008 tank ship. The Coast Guard has recorded 20 inspections since 2016, most recently in August 2026, along with 6 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 5 August 2026.

Built
2008
Last inspected
5 August 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 August 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9352212
994318
Flag
CAYMAN ISLANDS
Maury page id
psix-994318

Documentation record

Tonnage as PSIX records it25884 - Convention (Subpart B), Gross Ton
55675 - Displacement, Metric Ton
44080 - Dead Weight, Metric Ton
13427 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

20 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

5 August 2026 PSC B · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8449023
25 July 2025 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8193736
13 February 2024 Administrative Inspection · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7863967
1 February 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7630615
19 December 2022 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7610799
16 December 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7610356
24 February 2022 Appeal
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7401218
15 December 2021 Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7365204
22 August 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7039418
21 August 2020 MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7039007
17 August 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7035187
19 March 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6929118
28 October 2019 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6842889
16 May 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6679853
21 March 2018 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6376124
15 March 2018 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6372574
20 September 2017 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6270964
13 September 2017 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6265618
12 April 2017 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6122740
8 November 2016 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6035395

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 15 December 2021 Resolved
An audible alarm system independent of that required or automatic shutdown of cargo pumps shall be provided to operated on predetermined limits of low pressure in the inert gas main being reached. No audible alarm or independent shutdown observed.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 January 2022
Resolution: Class Report attesting to audible and visual alarms
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 15 December 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform to present regulations. Scrubber received shut down alarm. Vessel immediately conducted change over.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 December 2021
Resolution: Reviewed class report 19DEC21 that the scrubber system worked as designed and root cause of alarm was discovered.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 13 September 2017 Resolved
A tank overflow alarm must be audible and visible in that part of the deck where the containment systems are located and at the point where cargo loading is controlled on the tankship. The overflow alarm of the 3 starboard tank could not be seen or heard when tested. Rectify prior to cargo loading. 46CFR153.408(e) 16ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2017
Resolved 20 September 2017
Resolution: Received class report stating that the 3 starboard tank overflow alarm was repaired and tested successfully in the presence of the undersigned surveyor.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 13 September 2017 Resolved
A tank high level alarm must be seen and heard where cargo transfer is controlled and on the open deck. The high level alarm of the 1 port tank could not be seen or heard when tested. Rectify prior to cargo loading. 46CFR153.409(b) 16ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2017
Resolved 21 September 2017
Resolution: Received class report stating that the 1 port tank high level alarm is repaired and was successfully tested.
Communications › Visual Communication › Warning Sign (gangway)
Issued 13 September 2017 Resolved
A tank overflow must be identified with the legend “TANK OVERFLOW ALARM” in lettering as specified for the warning sign in 46CFR153.955. The tank overflow is identified in red letters. 46CFR153.408(d) 16ac
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 September 2017
Resolved 20 September 2017
Resolution: Received class report and pictures. The tank overflow alarm is identified in accordance with 46CFR153.408(d).
Communications › Visual Communication › Warning Sign (gangway)
Issued 13 September 2017 Resolved
The high level alarm must be marked as described in 46CFR153.408(c)(6). The high level alarm is marked in red letters. 46CFR153.409(d)/ 16 ac
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 September 2017
Resolved 20 September 2017
Resolution: Received class report and pictures. The high level alarm is identified in accordance with 46CFR153.409(d)

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.