MAURY USCG vessel records Sign in
← All vessels

PALAWAN STAR

PALAWAN STAR is a 2008 tank ship. The Coast Guard has recorded 18 inspections since 2009, most recently in March 2025, along with 9 deficiencies and 3 operational controls.

Records from 2009 to 2025. Most recent: inspection, 24 March 2025.

Built
2008
Last inspected
24 March 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9401233 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
994399
Flag
MARSHALL ISLANDS
—
Maury page id
psix-994399

Inspections, by type

…with no type recorded4
Years with a record 12 calendar years (2009–2025)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it42010 - Convention (Subpart B), Gross Ton
73802 - Dead Weight, Metric Ton
89327 - Displacement, Metric Ton
22454 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 18

24 March 2025 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8094580
25 March 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7884568
7 March 2024 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7873540
18 May 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7691446
25 March 2023 COC-CHEM & TVE Renew · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7657039
16 September 2021 COC-TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7313405
20 August 2019 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6789032
29 April 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6134987
8 August 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5965700
28 September 2015 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5730368
22 July 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4386210
22 July 2012 PI Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4386565
22 July 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4398047
10 January 2011 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3923896
24 January 2010 COC-CHEM Annual · MARPOL Annex VI Survey · Ballast Water Examination · ISPS III Exam · MARPOL Annex II Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3665803
14 March 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3431974
14 March 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3433646
18 January 2009 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · Deficiency Check · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3396031

Deficiency record · 9

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 March 2024 Resolved
After any survey of the ship...no change shall be made in structural arrangements , machinery, equipment and other items covered by survey without the sanction of the Administration. PSCO observed bent handrails on accomodation ladder, obstructing safe passage. 74 SOLAS (20) 1/11 - 40(a)(c)
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 March 2024
Resolution: Class (NKK) survey report provided attesting to repair of accomodation ladder by crew
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 22 July 2012 Resolved
0111/0135-Vessel is currently operating under an unattended machinery space. Due to the prior deficiency the vessel is not allowed to operate under an unattended machinery until the deficiency is rectified and cleared by class. Class has issued documentation voiding the UMS. SOLAS 09 (cons) I-10
Due 22 July 2012
Resolved 22 July 2012
Resolution: Class society provided an amended Class certificate voiding the UMS.
Engineering › Compressed Air System (start air) › Valve
Issued 22 July 2012 Resolved
0936- The number of consecutive automatic attempts which fail to produce start shall be limited to safeguard sufficient starting air pressure. Main air supply actuator is only operable by manual mode: and inoperable from bridge and engine control room. SOLAS 09 (cons) II-1/49.7. Rectified in 30 days.
Due 22 August 2012
Resolved 7 September 2012
Resolution: Received class report verifying that repairs have been completed.
Electrical › Lighting (service) › Grounding Conductor
Issued 10 January 2011 Resolved
1850; Main deck lights forward of the house must have grounding wires. Several lights on deck an on port bridge were found with broken or missing straps, 10/C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2011
Resolved 10 January 2011
Resolution: Discussed item with Captain, Chief Engineer and Electrician. Electrician replaced all missing wires and checked all other grounding wires.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 10 January 2011 Resolved
1830; Cargo Transfer procedures shall be in the format of and contain required information provided in 33 FCFR 155. Transfer procedures are missing required information, 10/C.
Action required: 705 - Other - as specified
Due 10 January 2011
Resolved 10 January 2011
Resolution: Discussed item with Captain and [name withheld] them a sample copy of transfer procedures as per 33 CFR.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 18 January 2009 Resolved
Inert gas system oxygen analyzer is indicating failure. Make repair and prove proper operation to Classification Society prior to conducting cargo operations. Provide copy of Class report to USCG New York prior to conducting cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2009
Lifesaving › Lifeboat › Propulsion Engine
Issued 18 January 2009 Resolved
Starboard side life boat engine will not remain running after start up. Make repair and prove proper operation to Classification Society prior to departing Port of New York. Provide copy of Class report to USCG New York prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2009
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 January 2009 Resolved
Oily water separator is not operating due to a malfunction of the oil monitoring device. Vessel is to retain all oily mixtures onboard for discharge to an approved reception facility until repair to the system is completed. Make permanent repair to the system, to the satisfaction of Classification Society, prior to departing Port of New York. Provide copy of Class report to USCG New York.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2009
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 18 January 2009 Resolved
Sprinkler head piping in inert gas generator space is showing signs of leaking/defective weld (2nd sprinkler head on right as you enter space). Make permanent repair to piping to the satisfaction of Classification Society by 18 FEB 2009.
Action required: 705 - Other - as specified
Due 18 February 2009
Resolved 19 January 2009

Ownership record