ANGEL NO.1 is a 2008 tank ship. The Coast Guard has recorded 4 inspections since 2018, most recently in August 2020, along with 4 deficiencies.

Records from 2018 to 2020. Most recent: inspection, 18 August 2020.

Built
2008
Last inspected
18 August 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 August 2020
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2018–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9434709
994700
Flag
PANAMA
Maury page id
psix-994700

Documentation record

Tonnage as PSIX records it8550 - Convention (Subpart B), Gross Ton
8550 - Simplified, Gross Ton
4055 - Simplified, Net Ton
13226 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

18 August 2020 PSC B · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7033209
11 June 2019 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6656888
14 June 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6444357
6 June 2018 ISPS II Exam · COC-TVE Renew · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6430999

Deficiency record · 4

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 18 August 2020 Resolved
Tankers shall be equipped with at least one portable instrument for measuring oxygen and one for measuring flammable vapour concentrations, together witha a suficient set of spare. Suitable means shall be provided for the calibration of such instruments. Multi-gas meters were not properly calibrated, and crew was unable to calibrate them when given the opportunity.
Action required: 10 - Deficiency Rectified
Resolved 18 August 2020
Resolution: Exam team returned to vessel and witnessed calibration of two portable instruments.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 August 2020 Resolved
Efficient guard rails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks. The port railing on main walkway access ladder is corroded. The starboard forward portable gangway support railing is corroded.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2020
Resolution: Received class report and photographs of railing repairs.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 18 August 2020 Resolved
After any survey of the ship under regulations 7,8,9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. Vessel is equiped with inert gas generator. During operational testing, I.G. system shut down unintentionally three times. Oxygen analyzer for I.G. system inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 December 2020
Resolution: Received class report. Vessel replaced O2 analyzer and tested satisfactorily.
Construction/Loadline › Markings › Load Line Mark
Issued 6 June 2018 Resolved
1, 1200, ICLL 66 Annex I/Reg. 8: The ring, lines, and letters shall be in white or yellow on a dark background or in black on a light background; markings of the portside loadline is painted the same color as the hull and not in white or black.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2018
Resolved 9 June 2018
Resolution: Received Class report and Loadline Painting evidence