MORNING CECILIE is a 2008 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in March 2026, along with 3 deficiencies.
Records from 2016 to 2026. Most recent: inspection, 4 March 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it60876 - Convention (Subpart B), Gross Ton 18263 - Convention (Subpart B), Net Ton 38562 - Displacement, Metric Ton 22699 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 12
4 March 2026PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8319639
21 April 2025Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8111596
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 April 2021Resolved
DOORS FITTED IN BOUNDRY BULKHEADS OF CATEGORY A SHALL BE SELF CLOSING AND NOT FITTED WITH HOLD BACK HOOKS. PSCO OBSERVED TWO HOLD BACK HOOKS ON THE TWO SELF CLOSING DOORS LEADING TO THE STEERING GEAR ROOM FROM GENERATOR SPACE IN ENGINEERING SPACE. 10C
Action required: 10 - Deficiency Rectified
Due 14 April 2021
Resolved 14 April 2021
Resolution: HOLD BACK DEVICES WERE REMOVED.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 July 2019Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship and all respects will remain fit to proceed to sea without danger to the ship or persons on board. The fixed water-based fire-extinguishing system in the engine room has a cracked weld on associated piping adjacent to the system's pump.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 October 2019
Resolution: Received class report and attended vessel to attest deficiency has been rectified.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 July 2019Resolved
Oil fuel pipes connected to a storage tank with a capacity of 500 liters shall be fitted with a valve capable of being closed from a safe position outside the space. The fuel tank in the EDG space was 975 litercapacity and did not have an emergency shut off.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 October 2019
Resolution: Received class report and attended vessel to attest deficiency has been rectified.