MARVIN G

MARVIN G is a 2009 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in May 2026, along with 15 deficiencies and 1 casualty investigation in 2017.

Records from 2016 to 2026. Most recent: inspection, 28 May 2026.

Built
2009
Last inspected
28 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE8540
994732
Flag
UNITED STATES
Maury page id
psix-994732

Documentation record

Registered dimensions (L × B × D)47.0 ft × 17.0 ft × 8.5 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderB & T WELDING LLC · BOOTHVILLE, LA, UNITED STATES · built 2009
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

28 May 2026 Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8354737
10 April 2025 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8109632
18 April 2024 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7881829
2 September 2023 Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7783039
23 March 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7619251
17 February 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7390562
2 March 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7138749
13 April 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6930948
19 February 2019 COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6618644
19 March 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6374669
15 August 2017 In-Service Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6241848
15 August 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6280230
6 April 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6119259
24 March 2016 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5838000

Deficiency record · 15

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 May 2025 Resolved
The engine head, block, and exhaust manifold must be water-jacketed and cool by water from a pump that operates whenever the engine is operating. The raw water pump on the port main engine was observed leaking at a rate of approximately one drop every two seconds while the engine was running. Repair to the satisfaction of attending MI. 46 CFR 182.420(a)(1) 60c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 May 2025
Resolution: Cleared on site by atttending MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to prevent electrical ignition of flammable vapors. The negative cable from the battery to the starter on the port main engine was found with a gash in the insulation, exposing the conductor. Repair to the satisfaction of attending MI. 46 CFR 182.200(d) 60c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 May 2025
Resolution: Cleared on site by atttending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 May 2025 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI found vessels generator inoperable. Demonstrate proper function to attending MI. 46 CFR 182.100 60c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 May 2025
Resolution: Cleared on site by atttending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2025 Resolved
A bilge pipe in a vessel of not more than 19.8 meters (65 feet) in length must be not less than 25 millimeters (1 inch) nominal pipe size. A bilge pipe in a vessel of more than 19.8 meters (65 feet) in length must be not less than 40 millimeters (1.5 inches) nominal pipe size. A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. MI's observed bilge foot located in Midship void to not be 3 times the area of the pipe. 46 CFR 182.510(b) 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 28 May 2025
Resolution: Cleared on site by atttending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 May 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. MI observed broken transfer frame on the STBD side of the midship void. 46 CFR 177.100 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 28 May 2025
Resolution: Cleared on site by atttending MI.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 September 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. It was reported that vessel was taking on water in stern void due to hull damage. Effect repairs to satisfaction of attending marine marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 October 2023
Resolution: Attended vessel drydocked, tested all repairs; test sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 March 2023 Resolved
A pre-engineering fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. The ships generator in the engine room did not shut down when the fire extinguishing system was tested. Make repairs to the pre-engineering fixed gas fire extinguishing system to the satisfaction of the MI. 46 CFR 181.420 (a)(3)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 March 2023
Resolution: Resolved to the satisfaction of the attending MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 March 2023 Resolved
Flexible nonmetallic hose meeting SAE standard J-1942 and permitted for use in piping installations in fuel oil service must be protected from mechanical damage and fabricated with an inner tube and a cover of synthetic rubber or other suitable material reinforced with wire braid. Port Main engine fuel oil return hose on inboard side of engine side was worn/chaffed through the outer cover exposing inner wire braid and fuel line to injectors on outboard side of engine was showed significant crease in outer jacket. Replace both with new hoses. 46 CFR 182.820(e)(3)(i)& (ii).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2023
Resolution: Resolved to the satisfaction of the attending MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 March 2023 Resolved
Flexible nonmetallic hose meeting SAE standard J-1942 and permitted for use in piping installations in lube oil service must be protected from mechanical damage and fabricated with an inner tube and a cover of synthetic rubber or other suitable material reinforced with wire braid. Port main engine oil cooling line for reduction gear was worn/chaffed through the outer cover exposing inner wire braid. Replace with new hose. 46 CFR 182.820(e)(3)(i)& (ii).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2023
Resolution: Resolved to the satisfaction of the attending MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 March 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Expansion tank for vessel's generator was missing cap. Re-cap 46 CFR 183.200(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2023
Resolution: Cleared to the satisfaction on the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 March 2023 Resolved
Electrical equipment exposed to corrosive environments must be of suitable construction and corrosion-resistant.Dirt and corrosion was found in the generator's windings. Clean housing for electrical windings. 46 CFR 183.210(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2023
Resolution: Resolved to the satisfaction of the attending MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 March 2021 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessels not more than 49 passengers and between 26-65 feet in lenght must have 1 fixed power pump and 1 portable hand pump, or 1 fixed hand pump and 1 portable hand pump. Vessels bilge pump was inoperable. Repair/replace bilge pump
Action required: 60 - Rectify deficiencies prior to movement
Due 16 March 2021
Resolved 3 March 2021
Resolution: Bilge pump replaced and operational test sat
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 2 March 2021 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Bilge/fire pump missing guard cover for pully and belt.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2021
Resolved 3 March 2021
Resolution: Guard installed over pulley and belt.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2021 Resolved
Each generator and motor must be designed for an ambient temperature of 50 °C (122 °F) except that: A generator or motor designed for 40 °C (104 °F) may be used in 50 °C (122 °F) ambient locations provided the generator or motor is derated to 80 percent of the full load rating, and the rating or setting of the overcurrent devices is reduced accordingly. Generator nameplate states it is designed for an ambient temperature 40 °C. Prior to operation of generator, Generator may be derated to 80% or provide a new nameplate from the manufacturer with the 50 °C ambient temperature rating.
Action required: 705 - Other - as specified
Due 16 March 2021
Resolved 3 March 2021
Resolution: Main circuit breaker changed to derate generator to 80%.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 15 August 2017 Resolved
Owner or operator shall make repairs to the extinguished CO2 system and prior to installation of manual pull, shall conduct test of manual pull cable in the presence of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 7 September 2017
Resolution: Installed new pre-engineered system FireBoy MA2, HFC-227ea cylinder and new, custom made 34 foot pull cable assembly. The pull cable was tested in the presence of the marine inspector.

Casualty record · 1

15 August 2017Routine · role: Involved in a Marine Casualty · activity 6280230
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.