← All vessels
ES SAKURA
ES SAKURA is a 2007 freight ship. The Coast Guard has recorded 16 inspections since 2009, most recently in December 2021, along with 10 deficiencies and 3 operational controls.
Records from 2009 to 2021. Most recent: operational control imposed, 25 December 2021.
- Built
- 2007
- Last inspected
- 25 December 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9374210 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EIY7
994848
Flag
PANAMA
—
Maury page id
psix-994848
Inspections, by type
…with no type recorded4
Years with a record
8 calendar years (2009–2021)
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it86824 - Displacement, Metric Ton
76596 - Dead Weight, Metric Ton
39737 - Convention (Subpart B), Gross Ton
25754 - Convention (Subpart B), Net Ton
76596 - Dead Weight, Metric Ton
39737 - Convention (Subpart B), Gross Ton
25754 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
25 December 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7372583
25 December 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7396261
22 March 2021
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7160604
10 March 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7153795
16 September 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6805762
6 July 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6469367
5 July 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6455530
26 June 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6456625
4 May 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6139010
12 October 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6012215
2 October 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6014049
28 February 2012
Deficiency Check · Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4247712
16 August 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4117588
15 August 2011
ISPS I Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4110339
13 August 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4110365
29 January 2009
ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3401850
Deficiency record · 10
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 July 2018
Resolved
(0700) Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO noted pinhole leak in fire main between cargo holds #4 and #5. 74SOLAS(04)II-2/14.2.1.2.
Fire Fighting › Fire Pumps › Pressure
Issued 12 October 2016
Resolved
0725-Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed that the emergency fire pump could not provide adequate pressure to fire mains on the starboard bridge wing and starboard bow. Have class witness adequate test- SOLAS 74(09cons)II-2/14.1.1 17ac
Fire Fighting › Fire Main › Condition
Issued 12 October 2016
Resolved
0725-Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed multiple pinhole leaks in the fire main located on the main deck between cargo holds #4 and #5. Have class attest to integrity of fire main- SOLAS 74(09cons)II-2/14.1.1 17ac
Lifesaving › Buoyant Smoke Signals › General
Issued 12 October 2016
Resolved
0650-Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights, not less than two of these shall also be provided with lifebuoy self-activating smoke signals located on port and starboard bridge wings. Therefore PSCO cannot determine compliance with LSA Code- SOLAS 74(09cons)III/7.1.3 LSA Code II/2.1.2 17ac
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 12 October 2016
Resolved
Each transfer pipe system must not leak under static liquid pressure at least 1 ½ times the maximum allowable working pressure. PSCO observed that the vessel tested their bunker lines to 1 times the maximum allowable working pressure. Prior to conducting bunker operations vessel must test bunker lines to 1 ½ times the maximum allowable working pressure- 33CFR156.170(c)(4)
Operations/Management › Pollution › Control of Discharge of Oil
Issued 15 August 2011
Resolved
1720-Control of oil Discharge - Any discharge into the sea of oily mixtures from a ship of 400GT and above shall be prohibited except when the oily mixture is processed through an oil filtering equipment. PSCO was informed by C/E that the vsl was discharging bilge water from the engine room wells through a installed bilge/ballast eductor system w/o first passing through OWS-MARPOL Annex I/15.
Documentation › Logs/Records › Oil Record Book
Issued 15 August 2011
Resolved
1710- Oil Record Book(ORB) - Each operation described in paragraph 2 of Regulation 17 shall be fully recorded without delay in the ORB. C/E admitted discharging overboard using the bilge/ballast pump as described in item #1. These operations were not recorded as required - MARPOL Annex I/17
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 15 August 2011
Resolved
2510-Safety & Environmental Policy- The company should ensure that the environmental policy is implemented and maintained at all levels of the organization both ship and shore based. Based on Items #1 & #2 the PSCO expanded the scope of the exam into the SMS and believes there is objective evidence that the C/E is disregarding the management polices set forth in PSMI-MN-08-00 - SOLAS74am IX/3
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 August 2011
Resolved
1745-15ppm Alarm Arrangements- Any ship 10000GT & above shall be fitted with Oil Filtering Equipment complying with paragraph 7 of MARPOL Reg 14. After review of the Oil Record Book (ORB) entries and stored data from the MEPC107(49) Oil Content Meter (OCM), the PSCO discovered numerous inconsistencies after 13Jan2011 between the ORB and the OCM data logger.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 15 August 2011
Resolved
1499- Other(Aux Machinery)- Each Bunker line transfer pipe must be tested annually and not leak under static liquid pressure at least 1.5 times the MAWP. Vessel conducted annual test however, air was used as a medium. Vessel is prohibited from conducting bunkering operations in U.S waters until bunker line is static liquid pressure tested and recorded (IAW 33CFR155.820). - 33CFR156.170
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.