← All vessels
DOLE WARI
DOLE WARI is a 2008 freight ship. The Coast Guard has recorded 27 inspections since 2009, most recently in July 2026, along with 15 deficiencies and 7 operational controls.
Records from 2009 to 2026. Most recent: operational control imposed, 30 July 2026.
- Built
- 2008
- Last inspected
- 30 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 15 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9399777 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6IF2
995077
Flag
BAHAMAS, THE
—
Maury page id
psix-995077
Inspections, by type
…with no type recorded9
Years with a record
7 calendar years (2009–2026)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it35556 - Dead Weight, Metric Ton
50187 - Displacement, Metric Ton
32984 - Convention (Subpart B), Gross Ton
13452 - Convention (Subpart B), Net Ton
32984 - Simplified, Gross Ton
13452 - Simplified, Net Ton
50187 - Displacement, Metric Ton
32984 - Convention (Subpart B), Gross Ton
13452 - Convention (Subpart B), Net Ton
32984 - Simplified, Gross Ton
13452 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
30 July 2026
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8450585
19 July 2026
Deficiency Check · PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8441546
19 July 2026
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8442420
1 February 2026
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8304574
17 January 2026
Deficiency Check · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8297717
6 July 2025
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8176352
10 March 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8091023
5 February 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8074994
23 December 2024
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8050285
16 June 2024
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7935758
20 March 2024
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7882506
20 June 2023
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7718683
22 April 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7673365
13 March 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7650406
7 December 2021
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7363693
14 May 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7199956
29 March 2021
Damage Survey · Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7164913
19 March 2021
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7159050
19 March 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7160415
16 March 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7155593
15 March 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7156510
12 March 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7154842
19 November 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6856235
6 February 2009
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3413331
6 February 2009
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3413354
5 February 2009
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3412889
4 February 2009
ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3412121
Deficiency record · 15
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 July 2026
Resolved
74 SOLAS (20) II-2/14.2.1.2: Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed no power to hypermist system control panel, rendering system non-operational.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 19 July 2026
Resolved
74 SOLAS (20) I/19.2.4.7: Ships fitted with AIS shall maintain AIS in operation at all times. PSCO observed AIS not functioning.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 July 2026
Resolved
74 SOLAS (20) I/11(b): After any survey of the ship, no change shall be made in structural arrangements without the sanction of the Administration. PSCO observed 05 fire doors that were not self-closing.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 July 2026
Resolved
74 SOLAS (20) III: Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. PSCO observed emergency lighting at embarkation stations non-operational.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 19 July 2026
Resolved
74 SOLAS (20) I/11(b): After any survey of the ship, no change shall be made in the structural arrangements, machinery, equipment without the sanction of the Administration. PSCO observed OWS 3-way valve sight glass unable to view and verify operation.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 January 2026
Resolved
In a ship which oil fuel is used, the arrangements for the storage, distribution and utliization of the oil fuel shall be such as to ensure the safety of the ship and persons onboard. / PSCO observed excessive oil accumulation in the engine room and around the main engine. SOLAS (20) II-2 reg 4.2.2. 16 ac
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 17 January 2026
Resolved
Systems and equipment, including associated back up arrangements, where applicable...to perform the functional requirements of regulations 19 & 20 shall conform to the appropriate performace stadards not inferior to those adopted by the organization. / PSCO observed faults on ships VDR test panel. SOLAS (20) V/ Reg 18.2 - 16 ac
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 6 April 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The vessel suffered a fire on March 29, 2021 in the engine room and lost primary generators and main propulsion. Status of critical systems are unknown and fixed fire protection system is at limited capacity.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 April 2021
Resolved
Machinery Spaces of Category A shall be protected by a fixed water based local application fire extinguishing system. In the case of periodically unattended machinery spaces, the local fire extinguishing system shall have both automatic and manual release capabilities. On board water mist fire extinguishing system did not discharge automatically during generator fire on March 29, 2021. System was not operational on April 4, 2021.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2021
Resolved
07199- THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. VESSEL WAS UNABLE TO START MAIN ENGINES WHILE GETTING UNDERWAY. VESSEL SUBSEQUENTLY MADE IMPACT WITH THE PIER. CLASS ATTENDANCE IS REQUIRED TO ATTEST TO CAUSE AND CORRECTIVE ACTION OF MAIN ENGINE MALFUNCTION AND TO THE EXTENT OF DAMAGE FROM IMPACT.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 19 November 2019
Resolved
Where the main steering gear comprises two or more identical power units, an auxiliary steering gear need not be fitted, provided that the PSCO observed when both #1 and #2 ran together, the steering indicator and rudder bounced back and forth 3-4 degrees when stopped. Solas 72a (09) II-I/ 29.6.1
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 November 2019
Resolved
Paint lockers shall be protected by carbon dioxide system. In all cases, the system shall be operable from outside the protected space. PSCO observed all 3 CO2 bottles had the safety pins still in the release valves.
Solas 74a (09) II-2/9.4.2.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 November 2019
Resolved
Doors required to be self closing shall not be fitted with hold-back hooks. PSCO observed 2 doors that were required to be self closing as per fire control plan had hold backs.
Solas 74(a)(09) II-2/9.4.2.2
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 February 2009
Resolved
Lifebuoy adjacent to stern launch life raft has an inoperable light, vessel has no other spares on board. Vessel is to acquire a lifebuoy light and witness satisfactory operation to the satisfaction of class.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 4 February 2009
Resolved
Vessel's Emergency Generator spring activated mechanical starting device has been inoperable since 28 December, 2008, class to attend vessel and witness satisfactory operation of the spring activated mechanical starting device prior to departure.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.