Records from 2015 to 2026. Most recent: inspection, 8 June 2026.
Documentation record
Registered dimensions (L × B × D)47.3 ft × 19.2 ft × 5.8 ft
Registered tonnagegross 35 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderH & H MARINE INC · STEUBEN, ME, UNITED STATES · built 2009
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portEASTPORT, ME
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 24 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Simplified, Gross Ton
28 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
8 June 2026
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8394895
16 March 2026
Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8326952
18 August 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8202019
24 October 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8022373
23 April 2024
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7898090
31 October 2023
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7819219
18 September 2023
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7838113
1 June 2022
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7465173
28 March 2022
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7417850
20 August 2021
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7317164
30 March 2020
Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6933108
21 August 2019
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6791384
15 June 2018
Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6443182
9 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6235617
22 September 2015
Simplified Stability Test
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5747008
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 August 2025
Resolved
Provide Coastwise endorsement on COD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 25 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 October 2024
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— Six hand red flare distress signals and 6 orange smoke distress signals.
Vessel had 6 red flairs on board during the time of inspection.
46 CFR 180.68(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2024
Resolved 29 October 2024
Resolution: Vessel POC sent pictures showing the flairs had been purchased and placed onboard.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 24 October 2024
Resolved
The master of the vessel shall ensure that:(b)The EPIRB battery is replaced after it is used, or before the date required by FCC regulations, whichever comes sooner. The EPIRB monthly test required shall also be logged. Vessel EPIRB battery was expired and monthly test not logged.
Vessel limited to one mile from shore.
Action required: 705 - Other - as specified
Due 24 October 2024
Resolved 26 November 2024
Resolution: Vessel POC sent pictures clearing the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel did not have life jacket placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 29 October 2024
Resolution: Vessel POC sent pictures showing the lifejacket placard posted onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 June 2022
Resolved
Provide medications to replace expired items.
Action required: 10 - Deficiency Rectified
Due 29 June 2022
Resolved 22 June 2022
Resolution: New first aid kit provided.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 22 June 2022
Resolved
Provide one 40 B.C. portable with bracket to meet COI and GA plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 24 June 2022
Resolution: New extinguisher installed on vessel per COI and GA.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2020
Resolved
Stbd side, aft engine mount was found broken. Lag bolt attaching engine to stringer sheered. Repair engine mount to original condition.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 June 2020
Resolved 22 June 2020
Resolution: Bolt removed and larger bolt used to secure mount.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 August 2019
Resolved
Indicator for high water in machinery space fails to reset when in operation. Prove operation of machinery space high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 September 2019
Resolution: Provided new switch for alarm, tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 August 2019
Resolved
Battery for ring buoy float light is expired. Provide non expired battery for ring buoy float light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 September 2019
Resolution: Replaced battery.