ELEEN ARMONIA is a 2008 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in October 2019, along with 8 deficiencies and 3 operational controls.
Records from 2016 to 2019. Most recent: inspection, 25 October 2019.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it55522 - Dead Weight, Metric Ton 64444 - Displacement, Metric Ton 30816 - Convention (Subpart B), Gross Ton 18122 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 April 2019Resolved
03199 - OTHER (LOAD LINES) - THE RING, LINES AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK GROUND OR IN BLACK ON A LIGHT GROUND. THEY SHALL ALSO BE PERMANENTLY MARKED ON THE SIDES OF THE SHIPS TO THE SATISFACTION OF THE ADMINISTRATION. THE MARKS SHALL BE PLAINLY VISIBLE AND, IF NECESSARY, SPECIAL ARRANGEMENTS SHALLS BE MADE FOR THIS PURPOSE. THE STARBOARD SIDE LOADLINES ARE BOTH PERMANENTLY DISPLAYED IN CONTRASTING COLORS; ONLY ONE MAY BE DISPLAYED AT ONE TIME. ICLL REG 8 - 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2019
Resolved 25 October 2019
Resolution: Recieved Class report Survey of [name withheld] stating the Load Line Issue was fixed and Satisfactory.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 8 December 2017Resolved
47SOLAS(14)II-2/10.1.1 FSS CODE 3.2.1.1.1 Protective clothing of material to protect skin from the heat radiating from the fire and from burn and scalding by steam. PSCO observed one of the two FFE's had damaged pand leg
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2017
Resolved 9 December 2017
Resolution: PSCO verified new fire suit onboard.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 9 September 2016Resolved
01 – 0750 Fire Prevention - Means shall be provided to control leaks of flammable liquids.
The number 3 cylinder on the main propulsion diesel engine was observed to have fuel leaks on the cylinder head from the high pressure fuel injector line connections. 74 SOLAS 2009 Chap. II-2/4.1.1 – 74 SOLAS 2009 Chap. I/Reg. 11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2016
Resolved 9 September 2016
Resolution: USCG examiners satisfied with repairs
02 – 0750 Fire Prevention - Means shall be provided to control leaks of flammable liquids.
The fuel lines connected to the burner assembly on the auxiliary boiler were observed to be leaking. Small, open top aluminum cans under the fuel lines to collect diesel fuel leaking above the burner unit were observed being used by vessel crew. 74 SOLAS 2009 Chap. II-2/4.1.1 – 74 SOLAS 2009 Chap. I/Reg. 1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2016
Resolved 9 September 2016
Resolution: USCG examiners satisfied with repairs
Fire Fighting › Combustible Materials › Insulation
Issued 9 September 2016Resolved
03 – 1470 Insulation wetted through (oil) - In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil or oil vapors.
A two foot section of insulation on piping forward of a duplex strainer in the fuel oil purifier deck was observed soaked through with oil. 74 SOLAS 2009 Chap. II-2/4.4.4.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2016
Resolved 9 September 2016
Resolution: USCG examiners satisfied with repairs
04 – 1430 Auxiliary Engine - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Ship service generator number 3 was not able to start. 74/78 SOLAS 2014 Cons. 1/11.1.a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2016
Resolved 15 September 2016
Resolution: Received, reviewed, and accepted class report attesting to the no. 3 generator being fully operational.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 9 September 2016Resolved
05 – 2550 Maintenance of ship and equipment - The safety-management system shall be maintained in accordance with the provisions of the International Safety Management Code.
The engine room was not being maintained as per the vessel Safety Management System, Part E, Section 3.13.4. 74 SOLAS 2009 Chap. IX/5
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 September 2016
Resolved 8 December 2017
Resolution: PSCO verified ISM Audit.
Engineering › Steam Boiler (auxiliary/waste heat) › Water Drum/Header
Issued 9 September 2016Resolved
06 – 1499 Other (Prop. & Aux. Machinery) - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The Auxiliary Boiler wash W.T. tank unusable due to material wastage on tank's bottom. 74/78 SOLAS 2014 Cons. 1/1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 September 2016
Resolved 15 September 2016
Resolution: Received, reviewed, and accepted class report attesting to the repairs of the Aux. Boiler Wash Tank.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.