MAURY USCG vessel records Sign in
← All vessels

KARDIANI

KARDIANI is a 2008 tank ship. The Coast Guard has recorded 23 inspections since 2009, most recently in April 2026, along with 5 deficiencies and 5 operational controls.

Records from 2009 to 2026. Most recent: inspection, 27 April 2026.

Built
2008
Last inspected
27 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9366263 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
995344
Flag
MALTA
—
Maury page id
psix-995344

Inspections, by type

…with no type recorded8
Years with a record 11 calendar years (2009–2026)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it44999 - Dead Weight, Metric Ton
54891 - Displacement, Metric Ton
29733 - Convention (Subpart B), Gross Ton
13661 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

27 April 2026 COC-CHEM & TVE Renew · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8353203
15 September 2025 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8234484
19 February 2025 COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8080600
14 February 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7865344
13 April 2022 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7442701
31 March 2022 COC-CHEM Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7422104
20 November 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7093960
23 May 2019 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6685025
8 November 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6301449
15 September 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6267263
14 September 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6266675
23 August 2017 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6249409
4 August 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6230684
4 February 2017 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6082835
11 October 2016 COC-CHEM Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6018925
9 December 2015 ISPS III Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5778891
14 November 2015 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5754514
6 October 2015 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5736654
29 October 2014 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5010684
22 October 2014 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5010069
27 January 2009 ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3399735
26 January 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3399451
26 January 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3400619

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 November 2020 Resolved
The fire integrity of the divisions shall be maintained at openings and penetrations. Self-closing door located at machinery space, "A" class boundry, aft of the main boiler, did not close. Additionally, the bulkhead penetraions had fire resistant material missing. 74 SOLAS 2004 II-2/9.1.3 10AC
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 November 2020
Resolved 20 November 2020
Electrical › Lighting (service) › Outlet Box
Issued 29 October 2014 Resolved
9800 - No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board oil tankers unless the Administration is satisfied. While conducting deck walk PSCO noted that deck lighting fixture on cargo block was deteriorated which compromises the hazardous location EX rating. 74SOLAS(04 cons) II-1/45.10.4 Action taken - 15c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2014
Resolved 5 November 2014
Resolution: The whole section of the deck lighting fitting was renewed with new casing and connector immediately. Regular and stringent inspection will be carried out to ensure that all the electrical equipment in any hazardous zone is properly maintained.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 29 October 2014 Resolved
1899 - The Administration shall be satisfied as to the maintenance of an adequate reserve of water at all times and the integrity of the arrangements to permit the automatic formation of the water seal when the gas flow ceases. While conductin deck walk PSCO noticed a leak on the inlet water line to the deck water seal. 74SOLAS(04 cons) II-2/4.5.5.1.1 & FSS Code 15.2.2.4.6 Action taken - 15c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2014
Resolved 5 November 2014
Resolution: The section of the inlet water line was taken out to engine workshop and the section of pin holed area was replaced with a new section of pipe. After fitting back the line was tested with working pressure and no further leak was found.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 29 October 2014 Resolved
0725 - Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO noted pin hole leak on the fire main line and leaking fire main isolation valve leading to the paint locker in the forward Bosun stores. 74SOLAS(04 cons) II-2/14.2.1.2 Action taken - 15c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2014
Resolved 5 November 2014
Resolution: The suspected leaking valve was renewed with new one. The line was opened up at the flanges and entire system was flushed at high pressure. After buffing and pressurizing the line, no leak or remarkable wastage of material found.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 29 October 2014 Resolved
1835 - During transfer operations the service vessel must have an oxygen analyzer with a sensor or sampling connection fitted within 3 meters of the vessel vapor connection that activates a visible and an audible alarm when the oxygen content in the vapor collection system exceeds 8 percent by volume. 46CFR39.4003(a)(2)(i)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2014
Resolved 5 November 2014
Resolution: After line blowing through for a prolong period, the equipment was showing correct Oxygen level and tested high Oxygen level alarm in good order. Additionally, two new spare Oxygen sensors arranged to be supplied at Panama on 7th November for future use

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.