MAURY USCG vessel records
← All vessels

IVS SHIKRA

IVS SHIKRA is a 2008 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in March 2017, along with 7 deficiencies and 1 operational control.

Records from 2016 to 2017. Most recent: inspection, 28 March 2017.

Built
2008
Last inspected
28 March 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 March 2017
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9370329
995372
Flag
PANAMA
Maury page id
psix-995372

Documentation record

Tonnage as PSIX records it17979 - Convention (Subpart B), Gross Ton
17979 - Simplified, Gross Ton
10748 - Convention (Subpart B), Net Ton
10748 - Simplified, Net Ton
29664 - Dead Weight, Metric Ton
35880 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

28 March 2017 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6108869
30 August 2016 PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5982219
18 August 2016 In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5976041
5 August 2016 COE-Offshore · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5958298
4 August 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5981739

Deficiency record · 7

Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 28 March 2017 Resolved
0610-Lifeboats-all life-saving appliances shall be in working order and ready for immediate use. PSCO observed port side lifeboat could not raise to cradle w/out circuit breaker tripping off-line. Only once the crew reset the breaker were they able to properly cradle the lifeboat. SOLAS 74 III/20.2. 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2017
Resolved 29 March 2017
Resolution: NKK class report stated: crew inadvertently left the securing pin out of the brake lever's locking mechanism, which was the reason for the breaker tripping off-line. Vessel released from restriction.
Lifesaving › Launching Appliances › Davit
Issued 5 August 2016 Resolved
0610 - Lifeboats - All life-saving appliances shall be in good working order and ready for immediate use. PSCO observed that the port side lifeboat was unable to be lowered. - SOLAS 74(Am) III/20.2 - 30a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 12 August 2016
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Launching arrangement devices' gripes were overhauled and freed. Lifeboat was lowered to the embarkation deck satisfactorily.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 5 August 2016 Resolved
0615 - Rescue Boats - All life-saving appliances shall be in good working order and ready for immediate use. PSCO observed that while lowering the rescue boat the gripes seized causing the lifeboat to collide with the deck. - SOLAS 74 (Am) III/20.2 - 17a
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 12 August 2016
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. No structural damage was found, rudder was repaired by ship's staff and propeller was found to be operating satisfactorily. Lifeboat was lowered satisfactorily.
Lifesaving › Lifeboat Equipment › Knife/Jack-knife
Issued 5 August 2016 Resolved
0611 - Lifeboat Equipment - All life-saving equipment shall conform with the code. All items of lifeboat equipment, shall be secured within the lifeboat. PSCO observed that both lifeboats had missing/expired/broken equipment on board such as expired hand flares, a destroyed survival manual, wet parachute flares, and an improperly stowed jack-knife. - SOLAS 74(Am) III/34 LSA Code 4.4.8 - 17a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 12 August 2016
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Missing/expired/improper lifeboat equipment was all replaced with satisfactory equipment.
Lifesaving › Launching Appliances › Davit
Issued 5 August 2016 Resolved
0696 - Record of inspections/maintenance - Inspections of the life-saving appliances shall be carried out monthly using the checklist. PSCO observed that grease fittings on both davits were painted over, causing maintenance to not have been carried out correctly. - SOLAS 74(Am) III/20.7.2 - 17a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 12 August 2016
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. All painted-over/dried grease nipples have been cleaned/renewed and made operational.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 5 August 2016 Resolved
1799 - Other (MARPOL Annex 1) - Each transfer pipe shall be tested to 1.5 times maximum allowable working pressure annually. PSCO observed that the most recent records of hydrostatic testing was conducted in August 2014. - 33CFR156.170(f)(3) - 40c
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 5 August 2016
Resolved 12 August 2016
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. Ship's staff carried out satisfactory hydrostatic tests of all bunker lines at 1.5X the MAWP.
Lifesaving › Visual Distress Signals (General) › Marking
Issued 5 August 2016 Resolved
0699 - Other(Life Saving Appliances) - Illustrations and instructions in appropriate languages shall be posted. PSCO observed that both boat deck mustering stations did not have proper life jacket donning procedures posted. - SOLAS 74 (Am) III/8.4.3 - 10c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 5 August 2016
Resolution: PSCO verified that crew had posted appropriate procedures for donning in both locations.

Ownership record