Records from 2016 to 2026. Most recent: inspection, 5 February 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CLERMONT, NJ, UNITED STATES · built 2009
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
16 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 16
5 February 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8304020
20 February 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8082492
30 January 2025
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8072507
11 December 2023
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7837584
25 July 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7752205
9 February 2023
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7631777
17 January 2023
Hull Examination · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7624179
4 May 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7448370
25 February 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7146467
15 January 2021
Internal Structural Exam · Hull Examination · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7128527
24 January 2020
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6895683
7 March 2019
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6637817
18 December 2018
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6599636
23 May 2018
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6421882
25 April 2017
COI Inspection · Hull Examination · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6127289
1 July 2016
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5926026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 February 2025
Resolved
Gauges to indicate engine revolutions per minute (RPM),
jacket water discharge temperature, and lubricating oil
pressure must be provided for all propulsion engines
installed in the vessel. The gauges must be readily
visible at the operating station. Marine Inspector
observed gauges not readily visible at operating
station. Vessel shall ensure gauges readily visible from
all angles. 46 CFR 182.410 (b)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2025
Resolution: Visited vessel to ensure visibility at helm for gauges. Operator placed new film on gauges.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 February 2025
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—(1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and(2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel only had 6 red hand held flares on board.
46 CFR 180.68(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2025
Resolution: New pyro placed on board.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 February 2025
Resolved
A power driven vessel underway shall exhibit:
sidelights. MI observed starboard running light unlit. Vessel limited to daylight hrs only until corrected.
33 CFR 83.23(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2025
Resolution: Vessel replaced running light, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 20 February 2025
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI observed rotating machinery. Vessel needs to replace guard.
46 CFR 177.960
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2025
Resolution: Vessel replaced guard, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 February 2025
Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. MI observed foam spray degradation between engine space and operating station. Vessel clean area and shall replace with fire retardant foam to ensure vapor tightness.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2025
Resolution: Vessel rep repaired to ensure vapor tightness.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2024
Resolved
Each life jacket must be marked with Type 1 retroreflective material. Marine Inspector found multiple life jacket with retro material in disrepair. Replace retro material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2024
Resolved 7 February 2024
Resolution: Vessel owner provided pictures of replaced retro.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 23 January 2024
Resolved
A penetration in a watertight bulkhead must be made watertight. Marine Inspector found fireboy cable run leaving engine compartment to be missing packing. Replace packing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2024
Resolved 7 February 2024
Resolution: Vessel owner supplied pictures of waterproofed cable penetration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 March 2021
Resolved
An exposed hazard, such as gears or rotating machinery must be properly protected by a cover.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 January 2020
Resolved
Port fuel tank vent pipe grounding wire broken.
Action required: 10 - Deficiency Rectified
Due 27 February 2020
Resolved 27 February 2020
Resolution: Stripped and reattached grounding wire to vent pipe through hull fitting.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 January 2020
Resolved
First aid kit contained expired medicines and excessive moisture causing mold.
Action required: 10 - Deficiency Rectified
Due 27 February 2020
Resolved 27 February 2020
Resolution: Replaced first aid kit with USCG approved assembly. 46 CFR 160
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 January 2020
Resolved
Vessel missing 1 of the 2 required portable battery operated lights.
Action required: 10 - Deficiency Rectified
Due 27 February 2020
Resolved 27 February 2020
Resolution: Installed additional portable battery powered light in emergency kit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2019
Resolved
First aid kit items must be IAW 46 CFR 160.041
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: Provided all required items for the onboard first aid kit.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 April 2017
Resolved
2 cracks on STBD side hand rails reweld.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 30 May 2017
Resolution: Cleared
Construction/Loadline › Penetrations › Gasket
Issued 25 April 2017
Resolved
Replace hatch gaskets on the forward and engine room Hatchs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 30 May 2017
Resolution: Cleared
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 April 2017
Resolved
Properly mount mast head light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 30 May 2017
Resolution: Cleared
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 July 2016
Resolved
Complete credit annual exam. Vessel is overdue for annual exam as of 13Jun16
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2016
Resolved 29 June 2017
Resolution: COI Conducted...