MAURY USCG vessel records Sign in
← All vessels

SEAWAYS ROSE

SEAWAYS ROSE is a 2008 tank ship. The Coast Guard has recorded 18 inspections since 2009, most recently in May 2024, along with 1 deficiency and 5 operational controls.

Records from 2009 to 2024. Most recent: inspection, 21 May 2024.

Built
2008
Last inspected
21 May 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9354911 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
996091
Flag
HONG KONG
—
Maury page id
psix-996091

Inspections, by type

…with no type recorded5
Years with a record 11 calendar years (2009–2024)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it56280 - Displacement, Metric Ton
47128 - Dead Weight, Metric Ton
29266 - Convention (Subpart B), Gross Ton
12026 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 18

21 May 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7915803
21 October 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7583207
13 October 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7571038
10 November 2021 COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7343428
5 May 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6947256
18 April 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6661089
15 April 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6663125
12 April 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6661446
1 March 2018 COE-Dockside
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6363753
18 January 2018 COE-Offshore · ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339541
3 September 2015 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5747206
22 May 2012 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4318408
10 May 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4307573
12 July 2011 COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4074089
11 July 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4074094
9 January 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3661364
10 February 2009 MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · COC-TVE Renew · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3415227
9 February 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3413534

Deficiency record · 1

Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 12 July 2011 Resolved
1099-Other Alarms- The tank overfill alarm required must have audible and visible alarm indications that can be seen and heard on the vessel in the cargo deck area. PSCO observed overfill alarms neither could be heard or seen from the cargo deck area. Provide documentation to the CG attesting to proper operation of the alarms on deck prior to loading oil in the U.S. -33CFR155.480
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2011
Resolved 13 July 2011
Resolution: Received, reviewed and accepted proper documentation from master stating the deficiency was rectified. Overfill alarm signals were repaired and photos of visual alarm signals sent to PSCO.

Ownership record