Records from 2009 to 2025. Most recent: inspection, 22 August 2025.
Documentation record
Registered dimensions (L × B × D)71.0 ft × 23.3 ft × 9.2 ft
Registered tonnagegross 85 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHILLSTROM SHIPBUILDING CO · COOS BAY OR, UNITED STATES · built 1969
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCOOS BAY, OR
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 10 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it85 - Regulatory (Subpart C or D), Gross Ton
57 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
22 August 2025
Excursion Permit · Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8215698
16 June 2025
Annual Inspection · Internal Structural Exam · DAPI Audit · Drydock Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8161111
10 July 2024
COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7955497
11 October 2023
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7806998
30 August 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7781253
6 October 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7573032
3 May 2021
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7234017
27 August 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7067626
28 July 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7020182
17 December 2019
Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6891609
11 July 2019
Initial Certification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6732744
26 September 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6548945
8 February 2016
Administration
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5811722
14 November 2010
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3892406
29 December 2009
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3673397
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 17 December 2019
Resolved
Coos Bay Towboat Company supervisors must conduct the annual 1-hour drug and alcohol (EAP) training required by 46 CFR § 16.401.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 28 July 2020
Resolution: Training conducted as required.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 11 July 2019
Resolved
08104 STEERING GEAR ALARM - LOW HYDRAULIC STEERING FLUID LEVEL ALARMS MUST BE PROVIDED. VESSEL IS NOT EQUIPPED WITH THE REQUIRED ALARM. INSTALL ALARM WITHIN 30 DAYS. 46 CFR 143.230(a)(6)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2019
Resolved 28 July 2020
Resolution: Witnessed operation of alarm.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 11 July 2019
Resolved
08105 - ENGINEERS' ALARM - AUXILIARY GENERATORS MUST BE EQUIPPED WITH HIGH COOLING WATER TEMPERATURE ALARMS. VESSEL IS NOT EQUIPPED WITH REQUIRED ALARMS. INSTALL ALARMS WITHIN 30 DAYS. 46 CFR 143.230(a)(4)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2019
Resolved 28 July 2020
Resolution: Witnessed operation of alarms.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 11 July 2019
Resolved
08105 - ENGINEERS' ALARM - EACH VESSEL WITH A FUEL DAY-TANK SHALL BE FITTED WITH LOW FUEL LEVEL ALARMS. VESSEL IS NOT EQUIPPED WITH THE REQUIRED ALARM. INSTALL ALARM WITHIN 30 DAYS. 46 CFR 143.230(a)(7)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2019
Resolved 28 July 2020
Resolution: Witnessed operation of alarm.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 September 2018
Resolved
Vsl is broadcasting: MMSI from expired FCC License, Call Sign from expired FCC License, incorrect Name, and greater/smaller than expected vessel length.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 October 2018
Resolved 13 December 2018
Resolution: AIS discrepancy corrected, AIS broadcasting all pertinent information.