MAURY USCG vessel records Sign in
← All vessels

IRIS PAOAY

IRIS PAOAY is a 2006 freight ship. The Coast Guard has recorded 21 inspections since 2009, most recently in July 2022, along with 12 deficiencies and 8 operational controls.

Records from 2009 to 2022. Most recent: inspection, 21 July 2022.

Built
2006
Last inspected
21 July 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9327592 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
DUA3560
996651
Flag
PHILIPPINES
—
Maury page id
psix-996651

Inspections, by type

…with no type recorded6
Years with a record 6 calendar years (2009–2022)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it19130 - Displacement, Metric Ton
13935 - Dead Weight, Metric Ton
9957 - Convention (Subpart B), Gross Ton
5032 - Convention (Subpart B), Net Ton
9957 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

21 July 2022 Deficiency Check · Administrative Inspection · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7512605
22 April 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7435994
31 January 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7388513
20 January 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7383012
8 September 2015 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5238142
15 June 2014 PII Safety Exam · Ballast Water Examination · ISPS II Exam · COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4889593
20 July 2012 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4384035
8 July 2012 Ballast Water Examination · ISPS II Exam · PII Safety Exam · COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4371114
27 November 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3897090
23 November 2010 COE-Dockside
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3897071
8 October 2010 COE-Dockside
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3865963
14 March 2010 COE-Dockside
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3695364
18 January 2010 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3665552
15 January 2010 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3664457
11 January 2010 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3662246
26 December 2009 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3655366
30 July 2009 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3550446
14 July 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3534040
19 April 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3456208
8 March 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3427291
16 February 2009 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3418512

Deficiency record · 12

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 July 2022 Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 L and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which tanks are situated. PSCO found (02) inoperable remote shutoff valves for HFO service tank #1 and HFO settling tank. 74 SOLAS (2104) II-2/4.2.2.3.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2022
Resolution: Vessel submitted class report
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 21 July 2022 Resolved
If a ship has any watch or work stations which are located remotely from the place or places where immersion suits are normally stowed, additional immersion suits of an appropriate size shall be provided at these locations for the number of persons normally on watch or working at those locations at any time. PSCO observed no immersion suits located on bridge. 74 SOLAS (2014) III/32.3.3
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 21 July 2022
Resolution: Vessel moved two spare immersion suits to bridge.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 21 July 2022 Resolved
The ship shall comply with the requirements of the ISM Code. The company should establish procedures, plans and instructions, invaliding checklist as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. Crew failed to follow procedures and operate OWS properly. 74 SOLAS (2014) IX/3.1 ISM Code Part (A) 7
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 July 2022
Resolution: Vessel crew demonstrated ability to follow proper procedures to properly operate OWS.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2022 Resolved
"A fixed fire-extinguishing system required by paragraph 5 below may be any of the following systems: a fixed gas fire-extinguishing system complying with the provisions of the Fire Safety Systems Code." Machinery space CO2 nozzles were identified to be water sprinkler nozzles and were not able to be verified as CO2 discharge nozzles meeting the discharge requirements of SOLAS and the FSS Code. 74 SOLAS (04) II-2 /10.4.1.1.1 FSS Code
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2022
Resolution: DNV Report: The nozzles were verified as per Type approval certificate (Minimax) and system manual (Type RD 1/2 x 6.6) and found in order.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 22 April 2022 Resolved
"Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use." Water mist discharge nozzles in the purifier room appeared caked and clogged, potentially preventing proper release if required. 74 SOLAS (04) II-2/14.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2022
Resolution: DNV Report: The nozzles above purifiers were removed, cleaned, and installed by crew. Attending surveyor tested the system manually and automatically; system working satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 April 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board." Vessel had multiple lighting covers cracked with 12+ missing bulbs, including lighting provided power by the emergency switchboard. 74 SOLAS (04) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 April 2022
Resolution: DNV Report: Damaged bulbs and covers replaced by crew and found in order.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 April 2022 Resolved
"The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems..." Smoke detector in purifier space was wrapped in a plastic bag, preventing proper operation of smoke detection. 74 SOLAS (04) II-2/14.2.1.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2022
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 April 2022 Resolved
"Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing." Door leading to engine room from the accommodation corridor would not fully close. 74 SOLAS (04) II-2/9.4.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2022
Resolution: DNV Report: The door was reparied by the crew; tested and working in order/fully closing.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 April 2022 Resolved
"The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids." Vessel had a catch basin under a leaking oil pipe near the purifier space and a catch bucket below the incinerator flat. 74 SOLAS (04) II-2/4.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2022
Resolution: DNV Report: Crew repaired leaking flange and tested system in operation; found no leaking.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 22 April 2022 Resolved
"The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems..." Flame detectors above incinerator were held together by tape and vessel did not have the proper testing equipment onboard. 74 SOLAS (04) II-2/14.2.1.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 June 2022
Resolution: Received DNV Class report attesting to proper operation.
Lifesaving › Immersion Suits › General
Issued 8 July 2012 Resolved
An immersion suit of an apporpriate size complying with the requirements of section 2.3 of the (LSA) Code, shall be provided for every person on board the ship. Vessel must replaced over-sized immersion suits with appropriate sized immersion suits, and provide USCG with reciept of purchase.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2012
Resolution: The immersion suits are able to maintain a seal. 04 crew members demonstrated and all approved.
Lifesaving › Immersion Suits › Readily Accessible
Issued 8 July 2012 Resolved
If ship has watch/work stations which are remotely located from place(s) where immersion suits are usually stowed... additional immersion suits of an appropriate size shall be provided at these locations. Deck department must stow appropriate - sized, easily accessible, immersion suits on bridge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2012
Resolution: Chief Mate placed two immersion suits on Navigatiion Bridge, along with corresponding placards, prior to departing.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.