Records from 2009 to 2023. Most recent: inspection, 28 June 2023.
Inspection history · 14
28 June 2023
Administrative Inspection · Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7725713
25 January 2022
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7385614
13 March 2020
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6928112
18 March 2019
Drydock Exam · Cargo Tank Internal · Examination of Repairs · COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6644638
19 April 2018
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6398540
9 June 2017
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6171528
10 May 2016
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5874347
28 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5864442
19 March 2015
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5086760
22 May 2014
Internal Structural Exam · COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4865057
21 November 2012
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4493393
7 March 2012
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4259050
17 August 2010
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3819584
29 May 2009
Cargo Tank Internal · Internal Structural Exam · Drydock Exam · MTSA Verification · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3489479
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 26 March 2019
Resolved
Cargo piping and vapor tightness were not completed at the time of the inspection
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 March 2019
Resolved 26 March 2019
Resolution: Testing of vapor header and cargo piping was being conducted at the time of the inspection
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 10 May 2016
Resolved
The liquid overfill protection alarms were unable to be tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 24 May 2016
Resolution: Attended vessel and verified Liquid Overfill alarm was working properly. Component was replaced with a new one. CG-835 cleared.