Records from 2009 to 2026. Most recent: inspection, 6 March 2026.
Inspection history · 25
6 March 2026
PSC B · COC-CHEM Renew
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8320877
15 November 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8268924
2 April 2025
PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8101454
2 December 2024
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8042186
25 March 2024
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7884384
1 August 2023
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7757705
3 March 2023
Administrative Inspection · COC-CHEM & TVE Annual
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7644275
3 July 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7494058
2 May 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7442519
3 March 2022
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7401912
16 April 2018
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6393103
29 March 2018
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6381826
8 January 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6334258
9 March 2017
ISPS III Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6101595
4 March 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6098861
26 March 2016
Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5841011
17 March 2014
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4817334
1 February 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3937225
28 October 2010
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3880005
28 October 2010
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3880156
28 October 2010
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3880171
4 March 2010
MARPOL Annex II Examination · COC-CHEM Annual · MARPOL Annex VI Survey · ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3687041
20 December 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3653122
6 March 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3428575
28 February 2009
Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3419813
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 March 2022
Resolved
Cargo Tanks shall be fitted w overfill alarm that activates an alarm early enough to allow the PIC to stop the cargo transfer before the tank overflows. PSCO found the vessels #9S, #3 P and #2 S cargo tank overfill alarms were activated. Must be retified prior to cargos that require inert gas. SOLAS 74(a)VII/10, IBC Code 15 , 46CFR39 Action 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2022
Resolved 16 March 2022
Resolution: Recieved Class report and vessel corrective action IAW with their SMS that was satisfactory to the PSCO.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 March 2022
Resolved
The inert gas system(N2) shall be designed to ensure that if the oxygen content exceeds 5% by volume the inert gas shall automatically be vented to atmosphere. The vessels crew were able to zero the nitrogen generator oxygen sensor but not able to span the sensor. 74SOLAS II-2 Reg5.5 FSS Code 2.2.2.4 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2022
Resolved 16 March 2022
Resolution: Recieved class report and corrective action IAW with the vessel's SMS. Ships officers were given training on the calibration of the O2 sensor and a technician tested the system and ensured proper calibration of the O2 sensor.
Lifesaving › Inflatable Liferafts › Weak Link
Issued 9 March 2017
Resolved
0630 - launch arrangt. for survival craft - The liferrafft painter system shall provide a connection between the ship and the liferaft and shall be so arranged as to ensure that the liferaft when released and, in the case of an inflateable liferaft, inflated is not dragged under by the sinking ship. PSCO observed that the painter line was not connected to the weak link. 74 SOLAS (14) III/34 10c
Action required: 705 - Other - as specified
Resolved 9 March 2017
Resolution: After reviewing the SOLAS training manual, the [name withheld] correctly attached the painter to the weak link.
Engineering › Steering Gear System › Rudder
Issued 28 October 2010
Resolved
Conducted Damage Survey on ship after grounding on the 27th of Oct 2010. Upon conducting steering gear test with bridge, inspector noticed difference in local rudder angle indicator and bridge. Further investigation indicated that there appears to be damage to the rudder and a difference of 20 to 17 degrees between the bridge and the local steering gear rudder angle indicator. Class is to atten
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 February 2011
Resolution: Vessel submitted class report from BV attesting to the repair and successful test of the steering gear system. Rudder, rudder angle indicator and control of steering gear system are all working properly.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 28 February 2009
Resolved
CODE 1100. C/T #6 STBD HIGH LEVEL AND TANK OVERFILL ALARMS NOT OPERATIONAL. RECTIFY NMT 14 DAYS OR PRIOR TO LOADING CARGO WHICHEVER OCCURS FIRST (SPARE PARTS ONBOARD). SOLAS CONSD 2004 VII/10, IBC 15.19. ACTION 16 (A)
Action required: 705 - Other - as specified
Due 14 March 2009
Resolved 6 March 2009
Resolution: Received class report attesting to satisfactory repair and operational test of cargo tank high level/overfill detectors and alarm. Deficiency cleared.