MAURY USCG vessel records
← All vessels

MISS CHLOE L ARMENTOR

MISS CHLOE L ARMENTOR is a 2009 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2016, most recently in July 2026, along with 29 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 23 July 2026.

Built
2009
Last inspected
23 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 July 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM4117
997186
Flag
UNITED STATES
Maury page id
psix-997186

Documentation record

Registered dimensions (L × B × D)48.0 ft × 20.0 ft × 4.0 ft
Registered tonnagegross 60 / net 60
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARTINEZ WELDING INC · PLAQUEMINE, LA, UNITED STATES · built 2009
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationMonohull
Hailing portBATON ROUGE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it60 - Simplified, Gross Ton
60 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

23 July 2026 Annual Inspection · Deficiency Check · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8445025
28 August 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8219818
28 February 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8086416
9 August 2023 Plan Review "T" Boat · Simplified Stability Test · Construction Oversight · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7791475
13 June 2022 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7476235
3 June 2021 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7215269
29 April 2020 Deficiency Check · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6945759
9 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6680394
15 May 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6415678
21 September 2017 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6272325
15 September 2016 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6001295
12 April 2016 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5856530

Deficiency record · 29

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 July 2026 Resolved
A flammable vapor detection system must provide a visual and audible alarm at the operating station. The vapor detection system was in fault mode and inoperable at time of inspection. Vessel shall ensure detection system is operable prior to departing the dock.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2026
Resolution: The vessel had the detector/sensor replaced and proved the system is operational.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 July 2026 Resolved
An operation and maintenance manual for the flammable vapor detection system must be kept onboard. No operation or maintenance manual was present at the time of the inspection. Additionally, vessel personnel were testing the vapor detection system by saturating a rag with gasoline. The vessel shall ensure that testing of the vapor detection system is conducted in accordance with the approved system manufacturer's recommendations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2026
Resolution: The vessel printed the operation and maintenance manual for the flammable vapor detection system and placed onboard.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 August 2025 Resolved
The owner or managing operator must conduct tests and inspections. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Portable and fixed firefighting service reports indicated the last service was completed in July of 2024. Provide current service reports for portable and fixed fire extinguishing equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2025
Resolved 28 August 2025
Resolution: O/O had techincian conduct inspection of fire fighting equipment and provided the service report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2022 Resolved
Drills and training must be logged or otherwise documented for review by the Coast Guard upon request. Log was missing. Create log to record drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 16 June 2022
Resolution: Completed and logged drills
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 June 2022 Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of 181.500 must be maintained in accordance with a recognized industry standard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 16 June 2022
Resolution: Excess FE equipment not meeting specs removed from vessel
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 June 2021 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. 46 CFR 67.313
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2021
Resolved 30 July 2021
Resolution: Copy of COD was placed onboard.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 3 June 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2021
Resolved 14 June 2021
Resolution: Received photo evidence of valid FCC license for vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 May 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Repair or replace corroded battery terminal connections on crane battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2020
Resolved 15 May 2020
Resolution: Vessel replaced terminal connections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2020 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters indicating purpose of the valve and direction of operation. Replace emergency fuel shutoff placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2020
Resolved 15 May 2020
Resolution: New sign posted.
Engineering › Bilge Water Management System › Pump
Issued 15 May 2018 Resolved
Electrical submersible bilge pumps must meet UL 1113. Replace bilge pumps with pumps meeting the UL standard
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 14 June 2018
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 May 2018 Resolved
Battery for the ring life buoy floating electric light is expired. Replace with acceptable battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 14 June 2018
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 May 2018 Resolved
Man overboard drills must be conducted and logged monthly. Conduct and log man overboard drill.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 16 July 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 26 September 2017 Resolved
Repair inoperable VHF.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 September 2017 Resolved
First Aid kits were incomplete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Navigation › Piloting/Steering › Marine Charts
Issued 26 September 2017 Resolved
Obtain updated publications and charts to include light list, coast pilot, etc.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 26 September 2017 Resolved
Install an A-II portable fire extinguisher in the accomodation space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 September 2017 Resolved
Aft ring buoy and attached line needs to be removed or replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 September 2017 Resolved
Ring buoys need to be marked with the full name of the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 September 2017 Resolved
Battery connections on starboard battery bank were loose and need to be cleaned.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Engineering › Fuel Oil Service System › Valve
Issued 26 September 2017 Resolved
Port fuel shut off needs to be re-labeled.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Engineering › Fuel Oil Service System › Gauge
Issued 26 September 2017 Resolved
Obtain a new sounding stick for the fuel tank that is marked for high and low levels.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 26 September 2017 Resolved
Provide a list of employees tested under the Drug and Alcohol program and the latest MIS report.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 September 2017 Resolved
Exceeded window for annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Engineering › Fuel Oil Service System › Hose
Issued 12 April 2016 Resolved
All engine fuel hoses were dry-rotted and all need to be replaced, as this creates a major fire/leak hazard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Resolution: Fuel hoses replaced
Stability › Watertight Integrity › General
Issued 12 April 2016 Resolved
Wire runs penetrating watertight bulkheads below the waterline need to be sealed, as this creates a potential for progressive flooding. There is also an empty penetration that needs to be welded closed.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Resolution: Filled protrusions with foam, made watertight
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 12 April 2016 Resolved
There is no anchor line provided for the anchor, so the vessel does not currently have the ability to anchor.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Resolution: Replaced anchor line
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 April 2016 Resolved
Attached water light for the ring buoy has an incorrect battery configuration. Must be resolved prior to carrying passengers at night.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2016
Resolution: Deck hand showed that battery configuration for ring life buoy was corrected. Cleared deficiency.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 April 2016 Resolved
02 PFDs were unserviceable. Total count of serviceable Type I PFDs is 13, so passenger count is reduced to 11 passengers and 2 crew.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Resolution: Replaced life jacket
Electrical › Electric Supply System (service) › Cable
Issued 12 April 2016 Resolved
Wires for the aft submersible bilge pump were chafed to the conductor, creating a shock hazard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Resolution: Repaired wire

Ownership record