MAURY USCG vessel records Sign in
← All vessels

JANE

JANE is a 2008 tank ship. The Coast Guard has recorded 28 inspections since 2009, most recently in November 2025, along with 3 deficiencies and 8 operational controls.

Records from 2009 to 2025. Most recent: inspection, 21 November 2025.

Built
2008
Last inspected
21 November 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9364588 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
997206
Flag
MARSHALL ISLANDS
—
Maury page id
psix-997206

Inspections, by type

…with no type recorded7
Years with a record 9 calendar years (2009–2025)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29733 - Convention (Subpart B), Gross Ton
13661 - Convention (Subpart B), Net Ton
51506 - Dead Weight, Ton
61419 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

21 November 2025 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8267899
17 October 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7578972
13 October 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7576036
20 February 2022 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7398771
19 February 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7421594
18 November 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7354082
14 June 2021 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7225003
20 April 2021 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7176456
29 January 2019 ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6614179
16 January 2019 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6611336
14 January 2019 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6609043
9 January 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6608203
16 October 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6284146
27 April 2017 ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6132921
24 January 2017 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6075900
13 September 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5993850
28 February 2012 Ballast Water Examination · COC-CHEM Renew
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4251718
27 February 2012 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4250490
27 February 2012 COE-Offshore · ISPS I Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4251845
24 February 2012 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4250431
16 March 2010 Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3696581
10 February 2010 COE-Administrative
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3677986
13 January 2010 COE-Administrative
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3661846
13 January 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3673174
12 January 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3662700
11 January 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3662260
13 March 2009 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3432782
5 March 2009 MARPOL Annex I Examination · COC-CHEM Renew · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3428219

Deficiency record · 3

Navigation › Collision/Grounding Avoidance › Radar
Issued 28 February 2012 Resolved
On each tanker of 10K GT or more a dual band radar system with short and long range capability is required. Master of vsl properly reported x-band radar inoperability prior to arrival. LOD issued, techs hired. Permanent repair required prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 February 2012
Resolved 28 February 2012
Resolution: Technician report received attesting to permanent repair of x-band radar (magnetron replaced).
Navigation › Collision/Grounding Avoidance › Radar
Issued 24 February 2012 Resolved
Vessel X-Band radar has been reported as not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2012
Resolution: Technician replaced magnetron, provided report attesting to proper operation of X-band radar.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 5 March 2009 Resolved
Portable vapors-detection instruments can not be properly calibrated for both toxic concentrations and flammable concentrations due to expired calibration gases. Cite: IBC Code, Chapter 13.2
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 March 2009
Resolved 12 March 2009
Resolution: PSCO received copy of recepit of span gas. Deficiency has been rectified.

Ownership record