Records from 2016 to 2026. Most recent: inspection, 11 May 2026.
Inspection history · 15
11 May 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8387288
29 April 2025
Hull Examination · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8123413
25 April 2024
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7899455
26 March 2024
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7885310
26 April 2023
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7679011
9 May 2022
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7446858
10 May 2021
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7193864
8 April 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7171378
27 July 2020
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7001468
2 April 2020
Drydock Extension
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6934502
24 April 2019
COI Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6669133
26 April 2018
Hull Examination · Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6400665
27 April 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6133959
19 July 2016
Spot Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5947397
28 April 2016
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5865374
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 May 2026
Resolved
The starboard side navigation light was inop. Do not operate at night or in low visibility until repaired.
Action required: 705 - Other - as specified
Resolved 26 May 2026
Resolution: Light repaired
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 April 2025
Resolved
Pre-engineered system installed in vessel's engine compartment was found to be extinguished. Replace with charged system prior to carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2025
Resolution: Fireboy was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 02 adult life jackets are missing from the vessel. Vessel is restricted to the carriage of a maximum of 16 people until 02 life jackets are added.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 3 June 2024
Resolution: Vessel has full complement of lifejackets
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 May 2024
Resolved
For fixed-gas fire extinguishing systems, the operator must provide satisfactory evidence of the required servicing to the marine inspector. The fireboy's serviing has expired.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2024
Resolved 3 June 2024
Resolution: Operator provided proof that fireboy was serviced
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2019
Resolved
The fire bouy engine shut off solenoid did not shutoff the engine.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 24 May 2019
Resolution: Fire bottle ext fixed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 26 April 2018
Resolved
Replace fire extinguisher.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 30 April 2018
Resolution: Installed new fire extinguisher.
Engineering › Steering Gear System › Actuator
Issued 27 April 2017
Resolved
Vessels steering system was leaking hydralic fluid at the helm.
Condition: Improper/Lack of Maintenance
Due 30 May 2017
Resolved 1 June 2017
Resolution: Leaks repaired.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 April 2017
Resolved
Inspect/replace battery in float light.
Condition: Improper/Lack of Maintenance
Due 30 May 2017
Resolved 1 June 2017
Resolution: New battery provided.