MARGARETE SCHULTE is a freight ship. The Coast Guard has recorded 15 inspections since 2016, most recently in July 2026, along with 5 deficiencies and 3 operational controls.
Records from 2016 to 2026. Most recent: inspection, 24 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it34670 - Dead Weight, Metric Ton 26671 - Convention (Subpart B), Gross Ton 46038 - Displacement, Metric Ton 12679 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
24 July 2026PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8444860
29 May 2026Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8383363
29 May 2026Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8383815
26 May 2026Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8380522
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 7 January 2026Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO oberserved steam leaking from boiler hose connection point.
74SOLAS (04) II-1/33.1
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 January 2026
Resolved 7 January 2026
Resolution: Gasket replaced by crew, steam no longer leaking.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 7 January 2026Resolved
Oil fuel pipes... sahll be of approved fire-resisting materials of adequate strength...PSCO observed damaged high-pressure fuel line on M/E cylinder no. 4.
74SOLAS(04) II-2/4.2.2.5.1
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 January 2026
Resolved 7 January 2026
Resolution: Braided stainless steel fuel line replaced by crew.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 August 2021Resolved
LAGGING ON NO. 3 GENERATOR WAS OIL SOAKED ON AFT SIDE PIPING ARRANGEMENT.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2021
Resolved 26 August 2021
Resolution: SDB recieved class report from KR. NO 3 Gen. is repaired and found SAT
Engineering › Lubricating Oil Service System › Valve
Issued 10 April 2018Resolved
01 1430 SOLAS (14 CONS) II-2/4.1 16AC MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. LUBE OIL LINE FROM AUX. ENGINES TO PURIFIER IS LEAKING AND SOAKED LAGGING.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2018
Resolved 2 December 2019
Resolution: Class report received attesting to satisfactory repair.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 10 April 2018Resolved
02 0700 SOLAS (14 CONS) II-2/14.2.1.2 10C FIREFIGHTING SYSTEMS SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. WATERMIST SISTEM FOR THE MAIN ENGINE WAS FOUND SECURED.
Action required: 10 - Deficiency Rectified
Due 10 April 2018
Resolved 10 April 2018
Resolution: [name withheld] THE VALVE FOR THE MAIN ENGINE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.