PEARL RIVER is a 2008 freight ship. The Coast Guard has recorded 13 inspections since 2009, most recently in February 2012, along with 2 deficiencies — 2 with no resolution recorded — and 5 operational controls.
Records from 2009 to 2012. Most recent: inspection, 6 February 2012.
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel report (PDF)Free with your email: this report as a file, an email when this vessel's record changes, and a list of the vessels you follow.Download vessel cardDownload QRMaury, US Coast Guard vessel record for PEARL RIVER, retrieved 18 September 2026. mauryrecords.com/v/psix-997510.html
Documentation record
Tonnage as PSIX records it9940 - Convention (Subpart B), Gross Ton 5020 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
6 February 2012ISPS II Exam · PII Safety Exam · COE-Offshore · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4235119
1 February 2012Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4236055
0750-Cables which are installed in hazardous areas introduce the risk of fire or explotion in the event of electric fault, special precautions shall be taken. Three (3) explotion proof light fixtures in the main deck were broken. 74SOLAS(CONS04) II-1 45.5.4-70ab
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 February 2012 — due date passed with no resolution recorded
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 31 January 2012No resolution recorded
1760-Hydrostatic testing for bunker lines shall be conducted annually. There is no record of hydrostatic test onboard. 33CFR156.170-70ac
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 6 February 2012 — due date passed with no resolution recorded
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National