MAURY USCG vessel records Sign in
← All vessels

CETACEAN

CETACEAN is a 1969 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1993, most recently in May 2026, along with 66 deficiencies.

Records from 1993 to 2026. Most recent: inspection, 13 May 2026.

Built
1969
Last inspected
13 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ5212
Flag
UNITED STATES
368560000 (licence lapsed)
Maury page id
psix-99755

Inspections, by type

Years with a record 31 calendar years (1993–2026)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.4 ft × 20.0 ft × 7.2 ft
Registered tonnagegross 25 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRUSSELL C. SCHOLL · BATON ROUGE, LA, UNITED STATES · built 1969
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 18 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE9636MMSI 368560000 · expired · compulsorily equipped · granted 22 July 2009, cancelled 21 September 2019 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 54

13 May 2026 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8356394
10 November 2025 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8266855
12 June 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8145675
24 April 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7900616
19 October 2023 Hull Examination · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7811231
18 April 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7670880
18 November 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7596775
11 April 2022 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7428465
28 October 2021 Hull Examination · Drydock Exam · Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7341401
13 July 2021 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7258117
2 July 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6993794
24 December 2019 Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6878574
19 April 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6666172
25 April 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6399560
8 November 2017 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6303684
20 September 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6271081
2 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6137898
16 February 2017 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6089906
15 February 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6089055
29 July 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5956983
6 July 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5931831
27 July 2015 Hull Examination · Deficiency Check · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5197523
7 May 2014 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4830899
2 May 2012 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4300221
27 July 2009 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3547361
2 October 2008 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3326958
9 September 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3303277
4 June 2007 COI Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2947902
24 October 2006 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2806511
22 August 2006 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2755784
5 October 2005 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2507498
30 November 2004 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2250242
19 August 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2170429
19 September 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1908727
6 January 2003 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1724575
3 September 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1670340
16 July 2002 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1630279
9 September 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1451763
24 January 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1056849
21 September 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 822918
28 July 1999 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1406548
25 January 1999 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1411801
6 August 1998 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1458558
24 September 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1117736
25 August 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1120088
25 July 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1431825
13 December 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1452235
29 July 1996 Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427244
21 September 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 877859
7 August 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1445000
20 January 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1389969
4 August 1994 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 867889
3 February 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 853184
9 August 1993 Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1155291

Deficiency record · 66

11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 June 2025 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Retroreflective material for 12 life jackets was deteriorated. Replace retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 16 June 2025
Resolution: Received photographic evidence that the deteriorated retro was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2024 Resolved
Each life jacket must be marked with Type 1 retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. Vessel rep rectified with purchase of 08 new life jackets bearing approved retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2024
Resolved 9 May 2024
Resolution: New life jackets were purchased, labeled with the vessels name and installed on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2024 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Light found inoperable; rectified with replacement.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2024
Resolved 9 May 2024
Resolution: Rectified with replacement.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 May 2024 Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Vessel rep rectified cable penetrations with marine grade sealant.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 9 May 2024
Resolved 9 May 2024
Resolution: Vessel rep rectified cable penetrations with marine grade sealant.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 11 April 2022 Resolved
Vessel required to have a valid Certificate of Documentation on board. COD was found to be expired. Vessel restricted from operating until valid COD is on board.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2022
Resolved 26 May 2022
Resolution: RCVD evidence of renewed COD. 835 cleared
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2022 Resolved
Life ring buoy was obstructed by seating and not readily accessible. Provide a location so the life ring buoy is easily deployed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 26 May 2022
Resolution: RCVD evidence of lifering relocation. 835 cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 April 2022 Resolved
Portable fire extinguishers must be mounted with approved bracket. Provide approved bracket for fire extinguisher by stairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 26 May 2022
Resolution: RCVD evidence of newly installed bracket. 835 cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 April 2022 Resolved
Vessel does not have required Rigging plan as required. Provide rigging plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 26 May 2022
Resolution: RCVD vessels rigging plan. 835 cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 July 2021 Resolved
Two adult lifejackets had deteriorated reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 5 August 2021
Resolution: retro repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 July 2021 Resolved
Lifering was missing Retroreflective tape.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 5 August 2021
Resolution: retro added
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 July 2021 Resolved
Audible and visual alarms for high level float switch was not operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 5 August 2021
Resolution: alarm and light working
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 July 2021 Resolved
Magnetic compass illumination was not working as well as the compass not functioning properly
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 5 August 2021
Resolution: magnetic compass replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 July 2021 Resolved
ring life buoy floating light lanyard is worn and deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 5 August 2021
Resolution: lanyard replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 July 2020 Resolved
Vessel did not have a current Radio Safety Telephony Certificate onboard. Small passenger vessels are required to have a detailed inspection of all radio installations as required by the FCC to recieve a safety rqadio telephony certificate. Provide evidence of vessel completing a satisfactory FCC compulsry inspection and valid radio safety telephony certificate onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2020
Resolved 11 July 2020
Resolution: Sent in pictyures of signed, valid, radio safety telephony certificate
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 January 2020 Resolved
Vessel was due for a hull exam on 31DEC2019. Vessel may not operate until successful completion of a hull exam.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2020
Resolution: Vessel completed a hull exam on 16JAN20.
Documentation › Certificates/Documents › FCC SSL
Issued 25 April 2017 Resolved
Need valid FCC Ship Station license onboard.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 2 May 2017
Resolution: New certificate on board
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 April 2017 Resolved
Need proof of Supervisor training.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 2 May 2017
Resolution: Provided proof of supervisory training
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 April 2017 Resolved
Need Consortium letter.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 2 May 2017
Resolution: Provided consortium letter
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 April 2017 Resolved
Need consortuim policy for vessel.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 2 May 2017
Resolution: Provided DAPI policy for vessel
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 April 2017 Resolved
Need to properly mount electrical box in panel room.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 2 May 2017
Resolution: Outlet box was properly mounted
Stability › Weathertight Integrity › General
Issued 25 April 2017 Resolved
Make all deck hatches weathertight and install securing devices.
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 20 September 2017
Resolution: Inspected.
Stability › Weathertight Integrity › General
Issued 25 April 2017 Resolved
Properly mark emergency hatches and make operable from both sides.
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 20 September 2017
Resolution: Inspected.
Lifesaving › Hand Flares › Storage
Issued 25 April 2017 Resolved
Stow flares in a serperate container.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 2 May 2017
Resolution: Demonstrated proper stowage of flares
Lifesaving › Visual Distress Signals (General) › Expired
Issued 14 July 2016 Resolved
Vessel's red flares expired. Ensure vessel has 3 current red & orange flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Vessel has required number of flares for route and all are current.
Fire Fighting › Fire Bucket › Availability
Issued 14 July 2016 Resolved
Vessel must have 3 fire buckets visibly marked "FIRE BUCKET" AND a portable hand pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Vessel now has 3 fire buckets correctly labeled and an operational portable hand pump.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 14 July 2016 Resolved
Bilge pumps must have visual indication of automatic operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: All bilge pumps have visual indication of automatic operation.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 14 July 2016 Resolved
High water bilge alarms must have labeled visual light indicators for each float switch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: All high water bilge alarms have audible and visual indications and are correctly labeled.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 14 July 2016 Resolved
"EMERGENCY EXIT, KEEP CLEAR" must be stenciled in 2-inch lettering on STBD hatch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Starboard emergency exit hatch correctly stenciled.
Electrical › Electric Supply System (service) › Cable
Issued 14 July 2016 Resolved
Ensure wiring in machinery space is properly supported.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Wiring in machinery space properly routed.
Documentation › Markings/Placards › Lifejacket Placard
Issued 14 July 2016 Resolved
PFD donning instructions placard must be visibly posted for passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: PFD donning instructions visibly posted for passengers.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 July 2016 Resolved
Ensure light bulb in starboard accommodation space is covered.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Lighting bulb in starboard accomodation space now covered with appropriate cover.
Lifesaving › Launching Appliances › Lines
Issued 14 July 2016 Resolved
Ensure cotter pins in rigging are properly installed for security and to avoid chafing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Cotter pins in rigging are all sufficiently installed to avoid backing out and no longer chafing the rigging.
Documentation › Logs/Records › Logbook (official)
Issued 14 July 2016 Resolved
Vessel must make lifesaving and drill logs current.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Drill and lifesaving logs made current.
Lifesaving › Lifebuoys › Serviceable
Issued 7 May 2014 Resolved
Life ring buoys line was rotten and unserviceable. Replace life ring buoy. per 46 CFR 180.70
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 13 June 2014
Resolution: New life ring provided.
Stability › Watertight Integrity › General
Issued 7 May 2014 Resolved
Repair or replace rotten wood in both port and starboard collision bulkheads to ensure watertight per stability letter.
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 13 June 2014
Resolution: New colision bulkhead fabricated with plywood and FRP overlay.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 June 2007 Resolved
Provide a Coast Guard approved first aid kit in way of eyewash, ammonia inhalants, and aspirin in accordance with 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 18 June 2007
Resolution: Provided a Coast Guard approved first aid kit in way of eyewash, ammonia inhalants, and aspirin in accordance with 46 CFR 184.710.
Fire Fighting › Fire Bucket › Quantity
Issued 4 June 2007 Resolved
Provide a 3rd 2.5 gallon fire bucket in accordance with 46 CFR 181.610.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 18 June 2007
Resolution: Provided a 3rd 2.5 gallon fire bucket in accordance with 46 CFR 181.610.
Stability › Watertight Integrity › Deadlight Cover
Issued 4 June 2007 Resolved
Replace the gasket on the port light in the starboard forward void in accordance with 46 CFR 179.350.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 18 June 2007
Resolution: Replaced the gasket on the port light in the starboard forward void in accordance with 46 CFR 179.350.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 June 2007 Resolved
Remove the dead end wire in the starboard forward void in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 18 June 2007
Resolution: Removed the dead end wire in the starboard forward void in accordance with 46 CFR 176.800.
Construction/Loadline › Structures › Deck Plating
Issued 4 June 2007 Resolved
Tighten the top bolt on the chain plate in the starboard forward void in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 18 June 2007
Resolution: Tightened the top bolt on the chain plate in the starboard forward void in accordance with 46 CFR 176.800.
Lifesaving › Lifebuoys › Approval
Issued 4 June 2007 Resolved
Provide a Coast Guard approved ring buoy in accordance with 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 18 June 2007
Resolution: Provided a Coast Guard approved ring buoy in accordance with 46 CFR 180.70.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 June 2007 Resolved
Conduct underway drills prior to the issuance of the Temporary Certificate of Inspection in accordance with 46 CFR 185.520 and 185.524
Action required: 705 - Other - as specified
Due 4 July 2007
Resolved 18 June 2007
Resolution: Conducted underway drills in accordance with 46 CFR 185.520 and 185.524
Construction/Loadline › Hull › Hull Plating
Issued 24 October 2006 Resolved
Replace plywood decking on port bow and stern
Action required: 705 - Other - as specified
Due 3 November 2006
Resolved 26 October 2006
Resolution: Replaced plywood as directed
Stability › Watertight Integrity › Weathertight Enclosure
Issued 24 October 2006 Resolved
Replace gaskets in port lights as needed
Action required: 705 - Other - as specified
Due 24 November 2006
Resolved 26 October 2006
Resolution: Replace gasket on port lights
Construction/Loadline › Hull › Hull Plating
Issued 24 October 2006 Resolved
Make repairs to port hull transom
Action required: 705 - Other - as specified
Due 24 November 2006
Resolved 26 October 2006
Resolution: Made repairs to the port hull transom
Lifesaving › Hand Flares › Not on Board
Issued 30 September 2004 Resolved
Provide one additional orange smoke flare IAW 46CFR 180.68
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2005
Resolution: All hand flares accounted for
Lifesaving › Lifebuoys › Serviceable
Issued 30 September 2004 Resolved
Replace deteriorated grabline on lifebuoy IAW 46CFR160.050
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2005
Resolution: Grabline condition satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 September 2004 Resolved
Provide structural support IAW 46CFR 177.900 for loose stanchions on port side railing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2004
Resolved 5 October 2005
Resolution: All stanchions properly secure.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 July 2002 Resolved
Properly mark escape hatch, starboard side aft in accordance with 46 CFR 185.606. LEGACY COMPONENT DESC: Escape Hatch
Due 16 August 2002
Resolved 3 September 2002
Resolution: Escape has was properly marked with signs.
Accommodation/Occupational Safety › Medical/First Aid
Issued 16 July 2002 Resolved
Renew all outdated items in first aid kit in accordance with 46 CFR 184.710. LEGACY COMPONENT DESC: Medicine Chest
Due 16 August 2002
Resolved 3 September 2002
Resolution: A new first aid was purchased and all items were satisfactory.
Engineering › Steering Gear System
Issued 16 July 2002 Resolved
Renew frayed steering cable starboard side in accordance with 46 CFR 182.610. LEGACY COMPONENT DESC: Cable
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 3 September 2002
Resolution: Cable replaced with new cable of same dimension and size. Cable looked new and operated satisfactorly.
Lifesaving
Issued 6 August 1998 Resolved
Provide ring buoy as per 46 CFR 180.70.
Condition: Unknown
Due 15 August 1998
Resolved 24 August 1998
Engineering
Issued 6 August 1998 Resolved
Replace portable fuel tank as per 46 CFR 182.458.
Condition: Unknown
Due 15 August 1998
Resolved 24 August 1998
Accommodation/Occupational Safety
Issued 25 July 1997 Resolved
Provide and install safety netting around the deck rails of the vessel in accordance with 46 CFR 177.35-1(c)
Condition: Unknown
Due 25 August 1997
Resolved 26 August 1997
Accommodation/Occupational Safety
Issued 25 July 1997 Resolved
Install vent with 30 X 30 mesh screen for the type III Marine Sanitation Device in accordance with 33 CFR 159.95(a)(2)
Condition: Unknown
Due 25 August 1997
Resolved 26 August 1997
Construction/Loadline
Issued 25 July 1997 Resolved
Provide and install adequate suction hose for required hand bilge pump thats long enough to reach the bottom of all compartments SEE 46 CFR 182.25-10(e).
Condition: Unknown
Due 25 August 1997
Resolved 26 August 1997
Lifesaving
Issued 25 July 1997 Resolved
Provide documentation that 50% of the crew has received first aid training in accordance with Coast Guard issued NVIC 1-91.
Condition: Unknown
Due 25 August 1997
Resolved 30 September 1997
Electrical
Issued 29 July 1996 Resolved
REMOVE WIRE NUTS FROM VESSEL AND RENEW WIH BUTT CONNECTORS OR SOLDERED/ TAPED CONNECTIONS.
Condition: Unknown
Due 29 August 1996
Resolved 3 September 1996
Construction/Loadline
Issued 29 July 1996 Resolved
MAKE PROPER REPAIRS TO THE FRACTURED FORWARD STBD MAIN DECK ESCAPE HATCH.
Condition: Unknown
Due 29 August 1996
Resolved 3 September 1996
Fire Fighting
Issued 29 July 1996 Resolved
PROVIDE ONE SERVICED B-I FIRE EXTINGUISHER PROPERLY MOUNTED.
Condition: Unknown
Due 29 August 1996
Resolved 3 September 1996
Accommodation/Occupational Safety
Issued 29 July 1996 Resolved
RENEW FRACTURED WINDOW ON CABIN AFT PORT SIDE.
Condition: Unknown
Due 29 August 1996
Resolved 3 September 1996
Electrical
Issued 29 July 1996 Resolved
PROPERLY INSTALL METAL WIRE CLAMPS EVERY 18" TO 24" ON ALL OVERHEAD WIRE RUNS.
Condition: Unknown
Due 29 August 1996
Resolved 3 September 1996
Lifesaving
Issued 7 August 1995 Resolved
PROVIDE MOISTURE TIGHT CONTAINER STENCILED WITH VESSEL'S NAME FOR DISTRESS FLARES.
Condition: Unknown
Due 7 August 1995
Resolved 7 August 1995
Lifesaving
Issued 7 August 1995 Resolved
PROVIDE 03 ADDITIONAL ORANGE DISTRESS FLARES.
Condition: Unknown
Due 7 August 1995
Resolved 7 August 1995
Navigation
Issued 7 August 1995 Resolved
PERMANENTLY MOUNT ANCHOR LIGHT IN ACCORDANCE WITH 72 COLREGS.
Condition: Unknown
Due 7 August 1995
Resolved 7 August 1995
Engineering
Issued 9 August 1993 Resolved
PROVIDE PLANS ON INSTALLED FUEL TANKS INCLUDING CAPACITY, DIMENSIONS, TYPE OF ALUMINUM, PIPING, FILL AND VENT SIZES. PROVE INSTALLATION AND TESTING FOR FUEL TANKS IAW 46CFR 182.15-25, 182.15-30, 182.15-40 AND 182.15-45.
Condition: Unknown
Due 9 August 1993
Resolved 9 August 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.