Inspection history · 21
13 May 2026
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8356394
10 November 2025
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8266855
12 June 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8145675
24 April 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7900616
19 October 2023
Hull Examination · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7811231
18 April 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7670880
18 November 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7596775
11 April 2022
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7428465
28 October 2021
Hull Examination · Drydock Exam · Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7341401
13 July 2021
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7258117
2 July 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6993794
24 December 2019
Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6878574
19 April 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6666172
25 April 2018
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6399560
8 November 2017
Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6303684
20 September 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6271081
2 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6137898
16 February 2017
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6089906
15 February 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6089055
29 July 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5956983
6 July 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5931831
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 June 2025
Resolved
Each life jacket must be marked with Type I
retroreflective material approved in 46 CFR 164.018 or
other standard specified by the Commandant. The
arrangement of the retroreflective material applied
after March 11, 1996, must be as specified by IMO
Resolution A.658(16). Retroreflective material for
12 life jackets was deteriorated. Replace
retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 16 June 2025
Resolution: Received photographic evidence that the deteriorated retro was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2024
Resolved
Each life jacket must be marked with Type 1 retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. Vessel rep rectified with purchase of 08 new life jackets bearing approved retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2024
Resolved 9 May 2024
Resolution: New life jackets were purchased, labeled with the vessels name and installed on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2024
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Light found inoperable; rectified with replacement.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2024
Resolved 9 May 2024
Resolution: Rectified with replacement.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 May 2024
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Vessel rep rectified cable penetrations with marine grade sealant.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 9 May 2024
Resolved 9 May 2024
Resolution: Vessel rep rectified cable penetrations with marine grade sealant.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 11 April 2022
Resolved
Vessel required to have a valid Certificate of Documentation on board. COD was found to be expired. Vessel restricted from operating until valid COD is on board.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2022
Resolved 26 May 2022
Resolution: RCVD evidence of renewed COD. 835 cleared
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2022
Resolved
Life ring buoy was obstructed by seating and not readily accessible. Provide a location so the life ring buoy is easily deployed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 26 May 2022
Resolution: RCVD evidence of lifering relocation. 835 cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 April 2022
Resolved
Portable fire extinguishers must be mounted with approved bracket. Provide approved bracket for fire extinguisher by stairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 26 May 2022
Resolution: RCVD evidence of newly installed bracket. 835 cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 April 2022
Resolved
Vessel does not have required Rigging plan as required. Provide rigging plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 26 May 2022
Resolution: RCVD vessels rigging plan. 835 cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 July 2021
Resolved
Two adult lifejackets had deteriorated reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 5 August 2021
Resolution: retro repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 July 2021
Resolved
Lifering was missing Retroreflective tape.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 5 August 2021
Resolution: retro added
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 July 2021
Resolved
Audible and visual alarms for high level float switch was not operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 5 August 2021
Resolution: alarm and light working
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 July 2021
Resolved
Magnetic compass illumination was not working as well as the compass not functioning properly
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 5 August 2021
Resolution: magnetic compass replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 July 2021
Resolved
ring life buoy floating light lanyard is worn and deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 5 August 2021
Resolution: lanyard replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 July 2020
Resolved
Vessel did not have a current Radio Safety Telephony Certificate onboard. Small passenger vessels are required to have a detailed inspection of all radio installations as required by the FCC to recieve a safety rqadio telephony certificate. Provide evidence of vessel completing a satisfactory FCC compulsry inspection and valid radio safety telephony certificate onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2020
Resolved 11 July 2020
Resolution: Sent in pictyures of signed, valid, radio safety telephony certificate
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 January 2020
Resolved
Vessel was due for a hull exam on 31DEC2019. Vessel may not operate until successful completion of a hull exam.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2020
Resolution: Vessel completed a hull exam on 16JAN20.
Documentation › Certificates/Documents › FCC SSL
Issued 25 April 2017
Resolved
Need valid FCC Ship Station license onboard.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 2 May 2017
Resolution: New certificate on board
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 April 2017
Resolved
Need proof of Supervisor training.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 2 May 2017
Resolution: Provided proof of supervisory training
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 April 2017
Resolved
Need Consortium letter.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 2 May 2017
Resolution: Provided consortium letter
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 April 2017
Resolved
Need consortuim policy for vessel.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 2 May 2017
Resolution: Provided DAPI policy for vessel
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 April 2017
Resolved
Need to properly mount electrical box in panel room.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 2 May 2017
Resolution: Outlet box was properly mounted
Stability › Weathertight Integrity › General
Issued 25 April 2017
Resolved
Make all deck hatches weathertight and install securing devices.
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 20 September 2017
Resolution: Inspected.
Stability › Weathertight Integrity › General
Issued 25 April 2017
Resolved
Properly mark emergency hatches and make operable from both sides.
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 20 September 2017
Resolution: Inspected.
Lifesaving › Hand Flares › Storage
Issued 25 April 2017
Resolved
Stow flares in a serperate container.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 2 May 2017
Resolution: Demonstrated proper stowage of flares
Lifesaving › Visual Distress Signals (General) › Expired
Issued 14 July 2016
Resolved
Vessel's red flares expired. Ensure vessel has 3 current red & orange flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Vessel has required number of flares for route and all are current.
Fire Fighting › Fire Bucket › Availability
Issued 14 July 2016
Resolved
Vessel must have 3 fire buckets visibly marked "FIRE BUCKET" AND a portable hand pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Vessel now has 3 fire buckets correctly labeled and an operational portable hand pump.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 14 July 2016
Resolved
Bilge pumps must have visual indication of automatic operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: All bilge pumps have visual indication of automatic operation.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 14 July 2016
Resolved
High water bilge alarms must have labeled visual light indicators for each float switch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: All high water bilge alarms have audible and visual indications and are correctly labeled.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 14 July 2016
Resolved
"EMERGENCY EXIT, KEEP CLEAR" must be stenciled in 2-inch lettering on STBD hatch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Starboard emergency exit hatch correctly stenciled.
Electrical › Electric Supply System (service) › Cable
Issued 14 July 2016
Resolved
Ensure wiring in machinery space is properly supported.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Wiring in machinery space properly routed.
Documentation › Markings/Placards › Lifejacket Placard
Issued 14 July 2016
Resolved
PFD donning instructions placard must be visibly posted for passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: PFD donning instructions visibly posted for passengers.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 July 2016
Resolved
Ensure light bulb in starboard accommodation space is covered.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Lighting bulb in starboard accomodation space now covered with appropriate cover.
Lifesaving › Launching Appliances › Lines
Issued 14 July 2016
Resolved
Ensure cotter pins in rigging are properly installed for security and to avoid chafing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Cotter pins in rigging are all sufficiently installed to avoid backing out and no longer chafing the rigging.
Documentation › Logs/Records › Logbook (official)
Issued 14 July 2016
Resolved
Vessel must make lifesaving and drill logs current.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 29 July 2016
Resolution: Drill and lifesaving logs made current.