MAURY USCG vessel records
← All vessels

GERD MAERSK

GERD MAERSK is a 2006 freight ship. The Coast Guard has recorded 25 inspections since 2016, most recently in April 2026, along with 16 deficiencies and 7 operational controls.

Records from 2016 to 2026. Most recent: operational control imposed, 17 April 2026.

Built
2006
Last inspected
17 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 April 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9320245
997619
Flag
DENMARK
Maury page id
psix-997619

Documentation record

Tonnage as PSIX records it126453 - Dead Weight, Metric Ton
98648 - Convention (Subpart B), Gross Ton
59086 - Convention (Subpart B), Net Ton
196796 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 25

17 April 2026 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8350660
21 October 2025 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8256362
11 March 2025 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8091750
1 October 2024 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8012444
18 March 2024 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7880913
19 January 2024 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7851899
11 December 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7837279
30 November 2023 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7831744
8 May 2023 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7683647
26 September 2022 PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7566202
14 February 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7395993
9 November 2021 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7347981
23 August 2021 Deficiency Check · PSC B · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7294200
17 July 2020 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7008794
12 July 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7003884
18 April 2020 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6940937
11 June 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6710893
6 June 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6705182
1 August 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6497552
23 April 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6397682
23 March 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6110165
15 December 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6058088
15 December 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6058382
15 December 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6058385
30 January 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5806355

Deficiency record · 16

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 17 April 2026 Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLICANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCO OBSERVED THAT PORT LIFE BOAT DID NOT START UPON INTIAL TEST DUE TO ISSUE WITH ENGINE DE-COMPRESSION LEVER. 74SOLAS(24) III/20.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2026
Resolution: VESSEL WAS ABLE TO START LIFE BOAT ON SECOND ATTEMPT, AFTER RETURNING DE-COMPRESSION LEVER TO PROPER POSITION FOR STARTING.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 11 December 2023 Resolved
The Administration shall ensure that radio equipment required by this chapter is maintained to provide the availability of the functional requirements specified in regulation 4 and to meet the recommended performance standards of such equipment. PSCO received dispensation letter from Flag state that the MF/HF radio is not operational. Technician stated that parts were not available in port to make necessary repairs. 74SOLAS(20)IV/15.5 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 January 2024
Resolution: recieved Service report confirming repair of Radio
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 30 November 2023 Resolved
In addition to meeting requirements of regulation 7, every ship engaged on voyages beyond sea areas A1 and A2, but remaining in sea area A3, shall be provided with an MF/HF radio installation capable of transmitting and receiving. PSCO confirmed that vessel's MF/HF unable to transmit. Next port of call is Oakland, CA and required parts are confirmed for Oakland, CA. 74 SOLAS (20) IV/ 10.2.1
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 1 January 2024
Resolution: recieved Service report confirming repair of Radio
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 February 2022 Resolved
The purpose of this regulation is to limit the fire growth potential in every space of the ship. Means of control for flammable liquids in the space shall be provided. PSCO observed 10 liters of hydraulic fluid accumulated in starboard bilge well.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 February 2022
Resolved 14 February 2022
Resolution: Vessel crew completed cleaning of starboard bilge well and confirmed by PSCO.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 9 November 2021 Resolved
Objective evidence discovered during an expanded ISM exam revealed the following major non-conformity; the vessel failed to fully implement the requirements of SMS. The vessel failed to fully establish maintenance procedures to ensure the ship is maintained in conformity with the provisions of the relevant rules. This is made evident by deficiencies 02, 03, 04, 05, and 06. An external audit is recommended. 74 SOLAS 14 IX/3.1 ISM Code 10.2
Action required: 30 - Ship detained
Resolved 15 November 2021
Resolution: PSCOs verified satisfactory results of external audit by ABS and verified all noted issues were rectified.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 November 2021 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. The following functional requirements shall be met. Means shall be provided to control leaks of flammable liquids. PSCO observed the following conditions while conducting exam of engine room: Excessive oil leak from no. 9 cylinder of main engine. Oil leak dripping on main engine exhaust from overhead main engine crane. Excessive oil leaking on the service generators no. 1, 2, and 3. Excessive oil leaking in the purifier room. hydraulic oil from turbocharger found on deck. Excessive oil found above and underneath the 100 ppm separator. Excessive oil found near main engine injectors. 74 SOLAS 04 II-2/4.1.1
Action required: 30 - Ship detained
Resolved 15 November 2021
Resolution: PSCOs verified satisfactory rectification of various oil leaks in engine room.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 9 November 2021 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed a hydraulic oil leak on the hydraulic pump of emergency generator while witnessing secondary independent means of starting. Last recorded test was on 02FEB2021 with last load test on 03NOV2021. Per SMS, emergency generator tests shall be completed weekly and load tests shall be completed monthly. 74 SOLAS 04 II-1/26.1
Action required: 30 - Ship detained
Resolved 15 November 2021
Resolution: PSCOs verified satisfactory operation of emergency generator and repair of oil leak on hydraulic pump for secondary independent means of starting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2021 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed dead end wire hanging near the starboard side of main engine. Vessel's crew was unable to identify wire and its function. 74 SOLAS 04 II-2/45.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2021
Resolution: PSCOs verified satisfactory repairs of dead end wire on starboard side of main engine.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 9 November 2021 Resolved
This subpart describes the authority exercised by Captains of the Port to ensure the safety of vessels and waterfront facilities, and the protection of the navigable waters and resources within. PSCO observed raw sewage in the engine room bilge. 33 CFR 160.101 ILO 147
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2021
Resolution: PSCOs verified the sewage found in bilge was pumped out by a third party.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 November 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The PSCO observed that the CO2 buzzer was hanging in place by its wire. 74 SOLAS 20 I/11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 November 2021
Resolution: PSCOs verified satisfactory repairs of ; Received Class/Flag/Tech report attesting to satisfactory test/operation of the CO2 buzzer.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 August 2021 Resolved
The arrangements for the storage, distribution, and utilization of oil used in pressure lubrication systems shall be as such to ensure the safety of the ship and persons on board. Lube oil collection buckets scattered throughout the engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 August 2021
Resolved 25 August 2021
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 August 2021 Resolved
The purpose of this regulation is to maintain and monitor the effectivness of the fire safety measures the ship is provided with. For the purpose, the following functional requirements shall be met: fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Quick closing valve to the F.O. low Sulpher settling tank was held open.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 25 August 2021
Resolved 23 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 August 2021 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. 01 smoke detector in the purifier space was inoperable upon initial testing. After repair by electrician the smoke detector is now fully operational.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 August 2021
Resolved 23 August 2021
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 6 June 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship is in all aspects will remain fit to proceed to sea without danger to the ship or person onboard. Ballas water piping leaking into engine room while under pressure. At a rate of less than (03) three oz. per minute.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2019
Resolved 11 June 2019
Resolution: Received class report attesting to the repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 June 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all aspects will remain fit to proceed to sea without danger to the ship or person onbaord. Found ventilation ducting snapped/broken from overhead and lashed to piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2019
Resolved 11 June 2019
Resolution: Received class report attesting to the repairs.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Injector (fuel injection)
Issued 15 December 2016 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. See Narrative.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 December 2016
Resolved 25 February 2017
Resolution: 06MAR17: Recieved Technician Report #06144562 stating retification of deficiency. New injection control unit was installed, main engine tested, found to be satisfactory.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.