Records from 2016 to 2026. Most recent: inspection, 8 July 2026.
Inspection history · 42
8 July 2026
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8432090
12 February 2026
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8310461
2 September 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8225193
8 May 2025
Annual Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8129697
30 July 2024
Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7970905
10 June 2024
Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7932340
18 April 2024
COI Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7897826
9 March 2024
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7876635
9 March 2024
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7876661
6 January 2024
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7847514
5 September 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7807687
1 August 2023
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7762079
5 June 2023
In-Service Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7704245
11 May 2023
Annual Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7677435
4 April 2023
Damage Survey · In-Service Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7663009
4 April 2023
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7663174
27 January 2023
Deadweight Survey · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7626788
10 January 2023
In-Service Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7622133
10 January 2023
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7680278
4 January 2023
In-Service Inspection · Deficiency Check · Damage Survey
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7616207
3 January 2023
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7616136
26 December 2022
Deficiency Check · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7613081
26 December 2022
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7614073
20 December 2022
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7614061
22 September 2022
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7580453
4 September 2022
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7551956
4 September 2022
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7552665
17 August 2022
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7536413
19 May 2022
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7449015
30 August 2021
Drydock Exam · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7303201
21 July 2021
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7271417
23 July 2020
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7011905
4 July 2020
Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7006062
18 September 2019
Deficiency Check · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6820680
19 August 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6815524
25 April 2019
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6670192
23 March 2019
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6647786
25 September 2018
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6549386
25 January 2018
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6343432
23 August 2017
Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6250118
25 May 2017
Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6166173
13 May 2016
DAPI Audit · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5875986
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 May 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have a means to reset devices used to automatically shut down ventilation systems and engines the following equipment at the operating station. The operating station engine override device for the starboard engine room Fireboy system was found to be inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2025
Resolved 14 May 2025
Resolution: Senior captain provided a video of the proper operation of the engine shutdown/override function.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 April 2024
Resolved
Each life ring buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter. Life ring is required to have vessel name written on it.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 10 June 2024
Resolution: Attached vessel name to lifering.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 April 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Repair splice in MSD compartment port side FWD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 10 June 2024
Resolution: Exposed excessive electrical tape and a proper splice was underneath. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 April 2024
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station. Repair STBD side bilge alarm. Alarm sounds but no visual.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 10 June 2024
Resolution: Replaced bilge alarm sensor. All sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 25 April 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2024
Resolved 28 August 2024
Resolution: Operator provided proof of a valid radio operator permit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel must prove to marine inspector that throttles has been repaired and repairs are satifactory.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2024
Resolved 12 March 2024
Resolution: Installed new throttles. Conducted u/w sea trial. Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 January 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel must prove to Marine Inspector that vessel propulsion is operating as designed. Conduct underway sea trail to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2024
Resolved 7 January 2024
Resolution: Conducted successful underway sea trial. Observed no alarms and felt no vibration on either engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 April 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Vessel wrapped starboard shaft with line. Conduct sea trial to the satisfaction of attending Coast Guard Marine Inspector prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2023
Resolution: Conducted underway sea trial. Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2023
Resolved
Submit Qualitative Failure Analysis to Marine Safety Center for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2023
Resolved 1 August 2023
Resolution: Received MSC approval for the engine control quantitative failure analysis.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 July 2020
Resolved
During their charter excursion they experienced a loss of propulsion. It was identified that the port engine starter stuck in the on position causing the engine to stall and not be able to restart.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2020
Resolved 14 July 2020
Resolution: A new starter was ordered and was used to replace the defective one.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 September 2019
Resolved
In the vicinity of the STBD side MDE hatch overhead/deck area there appears to be water intrusion, evidenced by the overhead being saturated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 27 September 2019
Resolution: Operator investigated water intrusion and found hole in deck by fuel shut off pull. Repaired hole in deck.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 September 2019
Resolved
VHF-FM radio was inop when tested. Required new installation of VHF-DSC capable radio and installed and tested by FCC tech. Vessel restricted to 1000 feet from dock until radio installed and verified by attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2019
Resolved 27 September 2019
Resolution: Installed DSC-VHF radio and satisfactorily tested radio communications.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 September 2019
Resolved
Vessels waterlight inop. Vessel restricted to daytime ops only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2019
Resolved 27 September 2019
Resolution: Replaced with new waterlight and tested satisfactorily.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 September 2019
Resolved
Port side nav light inop. Vessel restricted to daytime ops only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2019
Resolved 27 September 2019
Resolution: Installed new port nav light and tested satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 September 2019
Resolved
STBD side MDE has a lube oil leak IVO the rad gear. Recommended to vsl rep that he cleans engine to identify leak and repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 27 September 2019
Resolution: Operator investigated leak and found crack in hose that led from the turbo. Hose was replaced. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 September 2019
Resolved
Vessel first aid kit had multiple expired items. Instructed vessel rep to replace expired items, and provided rep with a printout of required items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 27 September 2019
Resolution: Replaced all expired items with new ones. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 April 2019
Resolved
Starboard side aft bilge pump float switch not operating as intended. Repair float switch and conduct operational test to satisfaction of local marine inspector. 46 CFR 176.804(h) ; 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 30 April 2019
Resolution: Satisfactorily tested bilge pump float switch.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 April 2019
Resolved
Wires that penetrate aft bulkhead in engine room space, both port and starboard need to be sealed. Repair to satisfaction of local marine inspector. 46 CFR 179.320 ; 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2019
Resolved 30 April 2019
Resolution: New sealant was put in place for wire bulkhead penetrations. All was satisfactory.